Non-Cochrane · intervention · PM42151053

Comparison of the cyclic fatigue resistance of original and replica-like files: a systematic review and meta-analysis.

Unal Mert, Cakici Fatih · Restorative dentistry & endodontics · 2026 · PubMed · doi:10.5395/rde.2026.51.e25

Findings

14 findings

Population
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Overall (temperature subgroup model, 51 comparison data sets)
SMD -1.197 [-1.830, -0.564]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Overall (temperature subgroup model, 9 comparison data sets)
SMD -1.719 [-4.270, 0.833]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Overall (kinematics subgroup model)
SMD -0.579 [-3.021, 1.862]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal
SMD -0.845 [-1.268, -0.423]
GRADE not reported
13 studies
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal
SMD -1.532 [-3.615, 0.550]
GRADE not reported
5 studies
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro)Replica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Overall (kinematics subgroup model)
SMD -1.395 [-4.075, 1.286]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), rotary filesReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Kinematics: rotary files
SMD -2.178 [-4.618, 0.262]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), rotary filesReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Kinematics: rotary files
SMD -1.819 [-2.331, -1.306]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), reciprocating filesReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Kinematics: reciprocating files
SMD 0.673 [0.052, 1.293]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), reciprocating filesReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Kinematics: reciprocating files
SMD 0.993 [-4.056, 6.042]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), tested at room temperatureReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Test temperature: room temperature
SMD -0.620 [-3.926, 2.685]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), tested at room temperatureReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Test temperature: room temperature
SMD -1.404 [-2.145, -0.664]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), tested at body temperatureReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesNumber of cycles to fracture (NCF), cyclic fatigue resistance
Laboratory, artificial root canal · Test temperature: body temperature
SMD -3.339 [-7.353, 0.675]
GRADE not reported
Studies not reported
Ni-Ti endodontic files tested for cyclic fatigue in artificial canals (in vitro), tested at body temperatureReplica-like Ni-Ti endodontic filesOriginal-brand Ni-Ti endodontic filesTime to fracture (TTF), cyclic fatigue resistance
Laboratory, artificial root canal · Test temperature: body temperature
SMD -0.631 [-1.853, 0.592]
GRADE not reported
Studies not reported

Included primary studies 14

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Alcalde 2020
Mechanical Properties of ProTaper Gold, EdgeTaper Platinum, Flex Gold and Pro-T Rotary Systems.
PMID:33353917
20201 other reviewTime to fracture (TTF), cyclic fatigue resistance; Number of cycles to fracture (NCF), cyclic fatigue resistancenot extracted yet
Martins 2022
Design, Metallurgical Features, and Mechanical Behaviour of NiTi Endodontic Instruments from Five Different Heat-Treated Rotary Systems.
PMID:35160955
20221 other reviewTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Alnoury 2024
Cyclic fatigue resistance of ProTaper gold and two replicalike rotary systems. An in vitro study
DOI:10.4103/sej.sej_89_23
2024this review onlyTime to fracture (TTF), cyclic fatigue resistance; Number of cycles to fracture (NCF), cyclic fatigue resistancenot extracted yet
Aydin 2024
Evaluation of Cyclic Fatigue Resistance of Novel Replica-Like Instruments in Static Test Model.
PMID:39206445
2024this review onlyNumber of cycles to fracture (NCF), cyclic fatigue resistancenot extracted yet
Lima 2024
Cyclic and torsional fatigue resistance of two replicalike and original brand reciprocating system
DOI:10.21726/rsbo.v21i2.2511
2024this review onlyTime to fracture (TTF), cyclic fatigue resistance; Number of cycles to fracture (NCF), cyclic fatigue resistancenot extracted yet
Martins 2020a
Mechanical Performance and Metallurgical Features of ProTaper Universal and 6 Replicalike Systems.
PMID:32898557
2020this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Martins 2020b
Influence of Kinematics on the Cyclic Fatigue Resistance of Replicalike and Original Brand Rotary Instruments.
PMID:32413441
2020this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Martins 2021a
Comparison of design, metallurgy, mechanical performance and shaping ability of replica-like and counterfeit instruments of the ProTaper…
PMID:33300121
2021this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Martins 2021b
Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments.
PMID:33829516
2021this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Rios-Osorio 2025
Dynamic cyclic fatigue resistance of Reciproc® Blue, One Reci®, R-Motion®, and two Replica-Like endodontic files after autoclave…
PMID:40485975
2025this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Tarrago 2025
Cyclic Fatigue Resistance of 'Replica-Like" and Original Reciprocating Instruments in Single and Double Curvatures.
PMID:40464535
2025this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Unal 2026
Comparison of Design, Cyclic Fatigue Resistance, and Metallurgical Properties of Original, Replica-Like, and Counterfeit Nickel-Titanium…
PMID:40794724
2026this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Uslu 2023
Comparison of mechanical resistance and standardisation between original brand and replica-like endodontic systems.
PMID:35703893
2023this review onlyTime to fracture (TTF), cyclic fatigue resistancenot extracted yet
Zanza 2022
Mechanical and Metallurgical Evaluation of 3 Different Nickel-Titanium Rotary Instruments: An In Vitro and In Laboratory Study.
PMID:35621499
2022this review onlyTime to fracture (TTF), cyclic fatigue resistance; Number of cycles to fracture (NCF), cyclic fatigue resistancenot extracted yet

Overlap with other reviews

Reviews that include the same primary studies are not independent evidence. Shared counts match studies by PMID, DOI or NCT, and otherwise by author and year (a probable match). Only the non-Cochrane dental reviews have study lists, so overlap with Cochrane reviews is not counted yet.

Review question

ElementPlanned (methods)Found (results)
PopulationNi-Ti endodontic instruments1,276 Ni-Ti endodontic files: nine original and 31 replica-like types (14 studies)
InterventionInstrumentation of the Ni-Ti files within artificial root canals (replica-like files)Replica-like files (rotary systems in 8 studies, Reciproc-type in 5, both in 1)
ComparisonOriginal files versus replica-like filesOriginal brand files
OutcomesCyclic fatigue resistance (time to fracture, number of cycles to fracture)Time to fracture (13 studies, 59 comparisons); number of cycles to fracture (5 studies, 11 comparisons)
Study designsLaboratory (in vitro) studies comparing original and replica-like files in the same setup with a standardized deviceIn vitro laboratory studies (static model in 12, dynamic in 2)
TimingPublished up to July 6, 2025; EnglishNot specified