Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

3,323 questions · 5,762 findings · 263 reviews · Dental caries

No studies found 321 · 5.6%GRADE not reported 4,450 · 77.2%Very low 455 · 7.9%Low 297 · 5.2%Moderate 200 · 3.5%High 39 · 0.7%

Ranked among the 5,000 newest matching findings; add words or filters to narrow the search.

Conventional bitewing radiography (E-speed film) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, conventional bitewing radiography (E-speed) pooled sensitivity was 0.48 (95% CI 0.21 to 0.77) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Edentulous (0 remaining teeth) vs 1-32 remaining teeth

All-cause mortality (ACM) · Adults (any age) with a known number of remaining teeth, followed prospectively in cohort studies

In prospective cohorts, the multivariable-adjusted HR for all-cause mortality in edentulous adults (0 teeth) vs adults with 1-32 teeth was 1.30 (95% CI 1.21 to 1.40; 7 studies, I2=20%); GRADE per-analysis ratings reported in Supplementary File 7 (not available in provided sources).

4 findings from 1 review
Show 1 more finding

Direct composite resin restoration vs Amalgam restoration

Restoration failure · People with permanent or adult posterior teeth requiring restoration (parallel-group trials involved children aged 6 to 12 years)

Direct composite resin restoration may leads to higher restoration failure rate compared with amalgam restoration (low certainty).

3 findings from 1 review

Chemotherapy (any regimen; added to, or compared with, locoregional treatment) vs Locoregional treatment and/or an alternative chemotherapy regimen

Quality of life · People receiving curative-intent treatment for oral cavity and oropharyngeal (squamous cell) cancer

The review found no eligible studies for this question.

1 finding from 1 review

Resin infiltration vs Untreated control (natural remineralization)

Optical/esthetic improvement (visual-tactile assessment) · Patients with post-orthodontic white spot lesions (WSL)

Resin infiltration produced significantly greater optical improvement of white spot lesions than untreated (naturally remineralizing) controls (SMD 1.24, 95% CI 0.59 to 1.88; moderate certainty).

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, laser fluorescence (DIAGNOdent 2095) pooled diagnostic odds ratio was 18.33 (95% CI 7.57 to 44.37) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, sensor-based (CCD/CMOS) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, sensor-based digital bitewing radiography had a pooled diagnostic odds ratio of 12.84 (95% CI 6.56, 25.13) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Dental erosion assessment vs None (descriptive prevalence review; subgroup analyses by urban/rural status, country and year)

Dental erosion prevalence · Five-year-old preschool children in Sharjah

One study found a high prevalence of dental erosion (58.8%) among 5-year-olds in Sharjah, associated with non-Emirati nationality, caries experience and sugary/carbonated beverage consumption (narrative synthesis; not GRADE-rated).

1 finding from 1 review

Visual examination (VE) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, visual examination pooled sensitivity was 0.46 (95% CI 0.20 to 0.73) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Rubber dam isolation and moisture control (alone or with saliva aspiration) vs Cotton rolls (with or without saliva aspiration)

Restoration survival · Dental patients undergoing direct or indirect restorative treatment (no age or gender restriction)

Rubber dam isolation and moisture control (alone or with saliva… may leads to higher survival rate of restorations (6 months) compared with cotton rolls (with or without saliva aspiration) (low certainty).

4 findings from 1 review
Show 1 more finding

CarieScan Pro device vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    CarieScan Pro (3 studies, 244 tooth surfaces): sensitivity ranged from 0.55 to 0.91. No evidence of a difference in accuracy by device type (Chi2=0.05, df=1, P=0.82).
    3 studies
    GRADE not reported

External control of fluoride concentration vs Not applicable

Water samples with fluoride concentration below the acceptable range · Brazilian cities in the Southeast region with artificially fluoridated public water supplies

In the Southeast region, 24.6% of samples were below the acceptable range.

1 finding from 1 review

17-24 remaining teeth vs 25-32 remaining teeth

Atherosclerotic cardiovascular disease (ACVD)-related events (morbidity and mortality) · Adults (any age) with a known number of remaining teeth, followed prospectively in cohort studies

In prospective cohorts, adults with 17-24 teeth had a higher cumulative incidence of ACVD-related events than adults with 25-32 teeth (RR 1.73, 95% CI 1.22 to 2.45; 4 cohort studies, I2=87%); GRADE per-analysis ratings reported in Supplementary File 7 (not available in provided sources).

1 finding from 1 review

0-19 remaining teeth vs 20-32 remaining teeth

All-cause mortality (ACM) · Adults (any age) with a known number of remaining teeth, followed prospectively in cohort studies

In prospective cohorts, the crude HR for all-cause mortality in adults with 0-19 teeth vs adults with 20-32 teeth was 2.47 (95% CI 2.40 to 2.54; 2 studies, I2=0%); GRADE per-analysis ratings reported in Supplementary File 7 (not available in provided sources).

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, phosphor plate (PSP) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, phosphor-plate digital bitewing radiography had a summary ROC AUC of 0.82 for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (dentin detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, conventional E-speed bitewing radiography had a pooled specificity of 0.91 (95% CI 0.80, 0.96) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Coating material (bonding material or sealant) WITH fluoride release vs Coating material WITHOUT fluoride release

Initiation of white spot lesions (WSL), visual-tactile assessment · People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)

Fluoride-releasing coating material did not show a statistically significant reduction in new white spot lesions versus non-fluoride coating (very low certainty).

1 finding from 1 review

Laser fluorescence (DIAGNOdent 2190/pen) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (caries detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, laser fluorescence (DIAGNOdent 2190) had a summary ROC AUC of 0.96 for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding