Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

2,745 questions · 4,389 findings · 203 reviews · Oral Health

No studies found 39 · 0.9%GRADE not reported 3,844 · 87.6%Very low 198 · 4.5%Low 137 · 3.1%Moderate 134 · 3.1%High 37 · 0.8%

Visual examination (VE) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the 1/3 dentin caries detection level (Ekstrand; D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, visual examination pooled specificity was 0.77 (95% CI 0.67 to 0.85) for occlusal caries at the 1/3 dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, conventional bitewing radiography (E-speed) pooled diagnostic odds ratio was 127.56 (95% CI 7.38 to 2203.70) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (D-speed film) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, conventional bitewing radiography (D-speed) pooled sensitivity was 0.65 (95% CI 0.57 to 0.73) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Cesarean section delivery vs Vaginal delivery

Caries prevalence (early childhood caries) · Toddlers and preschool children, 2 to 6 years of age (primary dentition)

Caesarean section delivery may be associated with a modestly higher prevalence of early childhood caries than vaginal delivery (pooled OR 1.48), but the evidence is inconsistent and of very low certainty.

1 finding from 1 review

Caries severity measurement (mean dmft for primary dentition; mean DMFT for permanent dentition) vs None (descriptive prevalence review; subgroup analyses by urban/rural status, country and year)

Caries experience · Healthy children and adolescents (primary and permanent dentition) in the United Arab Emirates

Caries severity was substantial, with mean dmft 0.75-10.9 (primary dentition) and mean DMFT 1.48-3.19 (permanent dentition), and higher indices in Emirati than non-Emirati children (narrative synthesis; not GRADE-rated).

1 finding from 1 review

Conventional bitewing radiography (E-speed film) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, conventional bitewing radiography (E-speed) pooled sensitivity was 0.80 (95% CI 0.71 to 0.87) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Visual examination (VE) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the 1/3 dentin caries detection level (Ekstrand; D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, visual examination pooled diagnostic odds ratio was 16.6 (95% CI 4.85 to 56.79) for occlusal caries at the 1/3 dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, phosphor plate (PSP) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, phosphor-plate digital bitewing radiography had a summary ROC AUC of 0.92 for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Clear aligners (Invisalign / thermoformed aligners) vs Fixed appliances

White spot lesions (WSLs), tooth level · Adults undergoing orthodontic treatment

A single study reported a lower risk of white spot lesions (tooth level) with aligners versus fixed appliances in adults at 3 months (RR 0.72, 95% CI 0.60 to 0.86; ungraded).

1 finding from 1 review

0-19 remaining teeth vs 20-32 remaining teeth

Atherosclerotic cardiovascular disease (ACVD)-related events (morbidity and mortality) · Adults (any age) with a known number of remaining teeth, followed prospectively in cohort studies

In prospective cohorts, the crude HR for ACVD-related events in adults with 0-19 teeth vs adults with 20-32 teeth was 2.27 (95% CI 1.50 to 3.43; 1 study, I2 not applicable (single study)); GRADE per-analysis ratings reported in Supplementary File 7 (not available in provided sources).

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography, F-speed film vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, conventional bitewing radiography (F-speed) pooled specificity was 0.97 (95% CI 0.71 to 0.998) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (D-speed film) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, conventional bitewing radiography (D-speed) pooled specificity was 0.73 (95% CI 0.53 to 0.87) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Visual examination (VE) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, visual examination pooled summary ROC AUC was 0.59 for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2190/pen) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, laser fluorescence pen (2190) pooled sensitivity was 0.78 (95% CI 0.44 to 0.94) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding