Non-Cochrane · intervention · PM42802882

Long-Term Peri-Implant Outcomes of Smoother/Hybrid Versus Moderately Rough Titanium Implant Surfaces: An Updated Systematic Review and Meta-Analysis.

Delgado Castromonte Heliette Emperatriz E, Jaramillo Arturo P, Hernandez Jiménez Juan S, et al. · Cureus · 2026 · PubMed · doi:10.7759/cureus.115357

Findings

Population Adults receiving root-form titanium dental implants

4 findings

Smoother, minimally rough, machined or hybrid titanium implant surfacesModerately rough or rougher titanium implant surfacesImplant failure
At least 24 months; longest eligible follow-up
RR 2.12 [0.85, 5.31]
Very low
Downgraded: risk of bias, imprecision
7 studies
Smoother, minimally rough, machined or hybrid titanium implant surfacesModerately rough or rougher titanium implant surfacesMarginal bone-level change
At least 24 months; longest eligible follow-up
Unresolved: the two extractors disagree on this row.
MD 0.07 [-0.12, 0.27]
Very low
Downgraded: risk of bias, imprecision, inconsistency
8 studies
Smoother, minimally rough, machined or hybrid titanium implant surfacesModerately rough or rougher titanium implant surfacesPeri-implant probing depth
At least 24 months; longest eligible follow-up
MD -0.36 [-0.93, 0.21]
Very low
Downgraded: risk of bias, imprecision, inconsistency
4 studies
Smoother, minimally rough, machined or hybrid titanium implant surfacesModerately rough or rougher titanium implant surfacesMarginal bone-level change
At least 24 months; longest eligible follow-up · Sensitivity analysis excluding high risk of bias reports
MD -0.06 [-0.29, 0.16]
GRADE not reported
5 studies

Included primary studies 10

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Donati 2018
Marginal bone loss at implants with different surface characteristics - A 20-year follow-up of a randomized controlled clinical trial.
PMID:29569767
2018this review onlyMarginal bone-level change; Peri-implant probing depthnot extracted yet
Glibert 2024
matched by author and year (probable)
NRthis review onlyMarginal bone-level change; Peri-implant probing depth; Implant failurenot extracted yet
Nicu 2012
RCT comparing implants with turned and anodically oxidized surfaces: a pilot study, a 3-year follow-up.
PMID:23151294
2012this review onlyPeri-implant probing depthnot extracted yet
Offord 2025
Four-Year Outcomes of Immediately Loaded Full-ArchMaxillary Dental Implants with Hybrid Versus Roughened Surfaces: A Split-Mouth…
PMID:41303033
2025this review onlyMarginal bone-level change; Implant failurenot extracted yet
Raes 2018
A 5-year randomized clinical trial comparing minimally with moderately rough implants in patients with severe periodontitis.
PMID:29611221
2018this review onlyMarginal bone-level change; Peri-implant probing depth; Implant failurenot extracted yet
Rocci 2013
Immediate loading of Brånemark system TiUnite and machined-surface implants in the posterior mandible, part II: a randomized open-ended…
PMID:23748324
2013this review onlyMarginal bone-level change; Implant failurenot extracted yet
Rothamel 2022
Impact of machined versus structured implant shoulder designs on crestal bone level changes: a randomized, controlled, multicenter study.
PMID:35841488
2022this review onlyMarginal bone-level change; Implant failurenot extracted yet
Serrano 2025
Three-Year Outcomes of Dental Implants With a Hybrid Surface Macro-Design Placed in Patients With History of Periodontitis: A Randomised…
PMID:40277088
2025this review onlyMarginal bone-level change; Implant failurenot extracted yet
Tirone 2021
Three-Year Evaluation of the Influence of Implant Surfaces on Implant Failure and Peri-implantitis: A Double-Blind Randomized Controlled…
PMID:33909728
2021this review onlyMarginal bone-level change; Implant failurenot extracted yet
Zetterqvist 2010
A prospective, multicenter, randomized-controlled 5-year study of hybrid and fully etched implants for the incidence of peri-implantitis.
PMID:20367092
2010this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationAdults receiving root-form (endosseous) titanium dental implantsAdults with titanium implants, from periodontally healthy fully edentulous patients to treated severe periodontitis; single crowns, partial fixed restorations, mandibular overdentures, immediately loaded maxillary full arch (n=10 reports; 480 participants; 1,219 implants)
InterventionMachined, turned, minimally rough, or hybrid implants with a smoother coronal componentTurned/machined/minimally rough surfaces or hybrid machined/minimally rough coronal zone (n=10)
ComparisonModerately rough or rougher implantsModerately rough surfaces (TiOblast, anodically oxidized TiUnite, continuously etched, structured shoulder, fully moderately rough) (n=10)
OutcomesPrimary: marginal bone-level change; secondary: peri-implant probing depth, implant failure; peri-implant disease (in PICOS question)Marginal bone-level change (n=8; 671 analysis units); peri-implant probing depth (n=4; 268 analysis units); implant failure (n=7; 773 implants); peri-implant outcomes narrative only (n=1)
Study designsRandomized clinical trialsRandomized clinical trials: parallel, multicenter and split-mouth (n=10)
TimingAt least 24 months of follow-up after implant placement or loading; longest eligible time point24 months to 20 years

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalNoNoyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalNoPartial Yesno
5Study selection in duplicateNoNoyes
6Data extraction in duplicateNoNoyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesYesno
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: N/ARCT: Yes · NRSI: N/Ayes
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: No · NRSI: N/ARCT: Yes · NRSI: N/Ano
12Impact of risk of bias on the pooled resultsYesYesyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalYesYesyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes