Primary study · included by 1 review

Immediate loading of Brånemark system TiUnite and machined-surface implants in the posterior mandible, part II: a randomized open-ended 9-year follow-up clinical trial.

Rocci 2013 · Rocci Antonio, Rocci Marta, Rocci Cecilia, et al. · The International journal of oral & maxillofacial implants · 2013

Included by

Outcome this study informsPooled effectEvidenceCertainty
Implant failure
Smoother, minimally rough, machined or hybrid titanium implant surfaces vs Moderately rough or rougher titanium implant surfaces · At least 24 months; longest eligible follow-up
RR 2.12 [0.85, 5.31]7 studiesVery low
Marginal bone-level change
Smoother, minimally rough, machined or hybrid titanium implant surfaces vs Moderately rough or rougher titanium implant surfaces · At least 24 months; longest eligible follow-up
MD 0.07 [-0.12, 0.27]8 studiesVery low
Marginal bone-level change
Smoother, minimally rough, machined or hybrid titanium implant surfaces vs Moderately rough or rougher titanium implant surfaces · At least 24 months; longest eligible follow-up
MD -0.06 [-0.29, 0.16]5 studiesGRADE not reported

1 including review in total.