Non-Cochrane · other · PM42645487

Impact of Thermocycling and Artificial Aging on the Flexural Strength and Fracture Resistance of CAD/CAM Dental Ceramics: A Systematic Review and Meta-Analysis.

Mora Bayas Joyce Michel, Chauca Bajaña Luis, Ortiz Bustamante Carol, et al. · Dentistry journal · 2026 · PubMed · doi:10.3390/dj14080513

Findings

25 findings

Population
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Overall
SMD -1.68 [-2.28, -1.08]
GRADE not reported
5 studies · 404 participants
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Multilevel random-effects model (dependent comparisons within studies)
SMD -1.68 [-2.73, -0.62]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Lauvahutanon VITABLOCS Mark II comparison (most negative pooled estimate)
SMD -1.84
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Almansour Ceramill ZI-LT comparison (largest change)
SMD -1.49
GRADE not reported
5 studies
Zirconia-based CAD/CAM ceramicsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Zirconia-based ceramics
SMD -3.31 [-4.27, -2.35]
GRADE not reported
2 studies · 120 participants
Lithium disilicate and lithium silicate CAD/CAM ceramicsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Lithium disilicate and lithium silicate ceramics
SMD -1.25 [-1.63, -0.87]
GRADE not reported
3 studies · 132 participants
Hybrid and PICN CAD/CAM ceramicsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Hybrid and PICN ceramics
SMD -1.37 [-1.74, -1.01]
GRADE not reported
3 studies · 148 participants
Feldspathic and glass-based CAD/CAM ceramicsThermocycling and/or artificial agingNon-aged control or baseline specimensFlexural strength
After aging protocol · Laboratory · Feldspathic and glass-based ceramics
SMD -0.47 [-1.35, 0.42]
GRADE not reported
2 studies · 68 participants
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Choo (IPS e.max CAD)
Pooled mean 1222.26 [895.29, 1549.24]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens (all categories) after artificial agingArtificial aging (thermocycling, water storage, mechanical fatigue, thermomechanical aging)None (single-arm post-aging values; no non-aged comparator)Fracture resistance (N), load-to-fracture after aging
In vitro laboratory testing · Sensitivity: leave-one-out, omitting Essam (IPS e.max CAD)
Pooled mean (N) 1283.71 [924.16, 1643.26]
GRADE not reported
4 studies · 108 participants
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Alnajjar (Lava Ultimate)
Pooled mean 1299.02 [941.25, 1656.78]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Al-Akhali (IPS e.max CAD)
Pooled mean 1368.52 [1056.60, 1680.43]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Choo (Katana UTML)
Pooled mean 1252.45 [901.45, 1603.46]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Elsayed (Celtra Duo)
Pooled mean 1252.77 [901.15, 1604.40]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Choo (Rosetta SM)
Pooled mean 1234.16 [894.66, 1573.66]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Alnajjar (IPS e.max CAD)
Pooled mean 1287.35 [928.00, 1646.69]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Al-Akhali (Vita Suprinity)
Pooled mean 1347.68 [1015.87, 1679.49]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out figure: overall random-effects model
Pooled mean 1289.07 [965.14, 1613.01]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Al-Akhali (Vita Enamic)
Pooled mean 1384.43 [1091.89, 1676.98]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Leave-one-out sensitivity: omitting Elsayed (IPS e.max CAD)
Pooled mean 1246.85 [898.44, 1595.27]
GRADE not reported
5 studies
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Sensitivity: excluding Al-Akhali et al. 2019
Pooled mean 1570.68 [1385.12, 1756.23]
GRADE not reported
4 studies · 126 participants
CAD/CAM dental ceramic specimens used for indirect restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Overall
Pooled mean 1312.85 [1131.59, 1494.10]
GRADE not reported
5 studies · 150 participants
Lithium disilicate (IPS e.max CAD) restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Lithium disilicate (IPS e.max CAD)
Pooled mean 1372.55 [1080.02, 1665.08]
GRADE not reported
5 studies · 88 participants
Zirconia and ZLS CAD/CAM restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Zirconia and zirconia-reinforced lithium silicate (ZLS)
Pooled mean 1528.18 [1320.70, 1735.67]
GRADE not reported
3 studies · 34 participants
Hybrid, PICN and resin nanoceramic CAD/CAM restorationsThermocycling and/or artificial aging (single-arm, post-aging values)None (no non-aged control pooled)Fracture resistance (N)
After aging protocol · Laboratory · Hybrid ceramics, PICN and resin nanoceramics
Pooled mean 766.92 [-43.59, 1577.44]
GRADE not reported
2 studies · 28 participants

Included primary studies 17

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Al-Akhali 2019
Fabricating a reduction guide for parallel guiding planes with computer-aided design and computer-aided manufacturing technology
DOI:10.1016/j.prosdent.2018.07.010
2019this review onlynot statednot extracted yet
Al-Akhali 2019
Influence of thermomechanical fatigue on the fracture strength of CAD-CAM-fabricated occlusal veneers.
PMID:30711291
2019this review onlyFracture resistance (N)not extracted yet
Almansour 2018
The Effect of <i>in vitro</i> Aging and Fatigue on the Flexural Strength of Monolithic High-translucency Zirconia Restorations
DOI:10.5005/jp-journals-10024-2349
2018this review onlynot statednot extracted yet
Almansour 2018
The Effect of in vitro Aging and Fatigue on the Flexural Strength of Monolithic High-translucency Zirconia Restorations.
PMID:30066693
2018this review onlyFlexural strengthnot extracted yet
Alnajjar 2024
Fracture Resistance of Posterior Milled Nanoceramic Crowns after Thermomechanical Aging.
PMID:39057293
2024this review onlyFracture resistance (N)not extracted yet
Choo 2023
Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study
DOI:10.1016/j.prosdent.2021.09.034
2023this review onlynot statednot extracted yet
Choo 2023
Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study.
PMID:34980473
2023this review onlyFracture resistance (N)not extracted yet
Elraggal 2023
Effect of acidic media on flexural strength and fatigue of CAD-CAM dental materials
DOI:10.1016/j.dental.2022.11.019
2023this review onlynot statednot extracted yet
Elraggal 2023
Effect of acidic media on flexural strength and fatigue of CAD-CAM dental materials.
PMID:36496258
2023this review onlyFlexural strengthnot extracted yet
Elsayed 2023
DOI:10.26355/eurrev_202302_31180
NRthis review onlynot statednot extracted yet
Elsayed 2023
Marginal gap distance and cyclic fatigue loading for different all-ceramic endocrowns.
PMID:36808333
2023this review onlyFracture resistance (N)not extracted yet
Essam 2023
Influence of thickness and surface conditioning on fracture resistance of occlusal veneer
DOI:10.1186/s12903-023-02932-0
2023this review onlynot statednot extracted yet
Essam 2023
Influence of thickness and surface conditioning on fracture resistance of occlusal veneer.
PMID:37138255
2023this review onlyFracture resistance (N)not extracted yet
Lauvahutanon 2014
Mechanical properties of composite resin blocks for CAD/CAM
DOI:10.4012/dmj.2014-208
2014this review onlynot statednot extracted yet
Lauvahutanon 2014
Mechanical properties of composite resin blocks for CAD/CAM.
PMID:25273052
2014this review onlyFlexural strengthnot extracted yet
Melc 2024
Flexural Strength of Modern CAD/CAM Restoratives After Artificial Aging.
PMID:39517453
2024this review onlyFlexural strengthnot extracted yet
Shafter 2017
Effect of Thermocycling on Flexural Strength of Different CAD/CAM Material
DOI:10.26420/jdentoraldisord.2017.1071
2017this review onlyFlexural strengthnot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationIn vitro studies of CAD/CAM dental ceramics for indirect restorations (lithium disilicate, zirconia, ZLS, feldspathic, glass ceramic, hybrid, PICN)CAD/CAM ceramics: lithium disilicate, lithium silicate, zirconia, ZLS, PICN, hybrid, resin nanoceramic, feldspathic and glass ceramics (n=10 studies)
InterventionThermocycling and/or artificial aging (hydrothermal, water storage, autoclave, mechanical fatigue, cyclic loading, chewing simulation)Thermocycling, water storage, mechanical fatigue, thermomechanical aging (n=10 studies)
ComparisonNon-aged control specimens or baseline values (flexural strength); no comparator required for fracture resistanceNon-aged controls (flexural strength, n=5 studies); none for fracture resistance (n=5 studies)
OutcomesFlexural strength (MPa) and fracture resistance (N); secondary: hardness, fracture toughness, elastic modulus, Weibull modulus, fatigue strength, survivalFlexural strength (n=5 studies, 16 comparisons); fracture resistance (n=5 studies, 11 comparisons)
Study designsIn vitro studiesIn vitro studies (n=10)
TimingNot specifiedNot specified

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsNRYesno
2Protocol established before the reviewcriticalNRPartial Yesno
3Choice of study designs explainedNRNono
4Comprehensive literature searchcriticalNRYesno
5Study selection in duplicateNRYesno
6Data extraction in duplicateNRYesno
7List of excluded studies with reasonscriticalNRNono
8Included studies described in detailNRPartial Yesno
9Risk of bias assessed satisfactorilycriticalNRRCT: Yes · NRSI: N/Ano
10Funding of included studies reportedNRNono
11Appropriate meta-analysis methodscriticalNRRCT: Partial Yes · NRSI: N/Ano
12Impact of risk of bias on the pooled resultsNRNono
13Risk of bias accounted for in interpretationcriticalNRYesno
14Heterogeneity explainedNRYesno
15Publication bias investigatedcriticalNRPartial Yesno
16Conflicts of interest reportedNRYesno
OverallNRLowno