Primary study · included by 1 review

The Effect of in vitro Aging and Fatigue on the Flexural Strength of Monolithic High-translucency Zirconia Restorations.

Almansour 2018 · Almansour Hosain M, Alqahtani Fawaz · The journal of contemporary dental practice · 2018

Included by

Outcome this study informsPooled effectEvidenceCertainty
Flexural strength
Thermocycling and/or artificial aging vs Non-aged control or baseline specimens · After aging protocol
SMD -1.68 [-2.73, -0.62]5 studiesGRADE not reported
Flexural strength
Thermocycling and/or artificial aging vs Non-aged control or baseline specimens · After aging protocol
SMD -1.68 [-2.28, -1.08]5 studies · 404 participantsGRADE not reported
Flexural strength
Thermocycling and/or artificial aging vs Non-aged control or baseline specimens · After aging protocol
SMD -1.495 studiesGRADE not reported
Flexural strength
Thermocycling and/or artificial aging vs Non-aged control or baseline specimens · After aging protocol
SMD -1.845 studiesGRADE not reported

1 including review in total.