Non-Cochrane · intervention · PM41924677

Digital Versus Conventional Splints in Patients With Temporomandibular Disorders: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Almansour Fahad W, Alshammari Khaled, Mohammed Alhajri Dhari, et al. · Cureus · 2026 · PubMed · doi:10.7759/cureus.105977

Findings

Population Patients with temporomandibular disorders

13 findings

Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Pai et al. 2025
MD -0.33 [-1.13, 0.47]
GRADE not reported
6 studies · 354 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Hussein et al. 2025
MD -0.22 [-1.08, 0.64]
GRADE not reported
6 studies · 358 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPatient satisfaction (Likert scale)
Not specified
MD 0.20 [-1.26, 1.66]
GRADE not reported
4 studies · 80 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Pho Duc et al. 2016
MD -0.31 [-1.07, 0.45]
GRADE not reported
6 studies · 346 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Chen et al. 2026
MD 0.03 [-0.65, 0.72]
GRADE not reported
6 studies · 246 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintMaximum mouth opening
Not specified · Maximum mouth opening
MD -0.10 [-0.97, 0.77]
GRADE not reported
3 studies · 158 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintLimited mouth opening
Not specified · Limited mouth opening
MD -0.09 [-1.03, 0.86]
GRADE not reported
2 studies · 62 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Algabri et al. 2017
MD -0.04 [-0.77, 0.68]
GRADE not reported
6 studies · 348 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Berntsen et al. 2018
MD -0.20 [-0.92, 0.51]
GRADE not reported
6 studies · 364 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintMouth opening (limited and maximum combined)
Not specified · Overall of limited and maximum subgroups
MD -0.09 [-0.73, 0.55]
GRADE not reported
5 studies · 220 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up
MD -0.22 [-0.92, 0.48]
GRADE not reported
7 studies · 378 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintPain intensity (VAS)
Last available follow-up · Leave-one-out sensitivity analysis: omitting Qin et al. 2025
MD -0.45 [-1.13, 0.23]
GRADE not reported
6 studies · 252 participants
Digitally fabricated (CAD/CAM) occlusal splintConventionally fabricated occlusal splintClinical occlusal adjustment time (minutes)
Not specified
MD -9.10 [-15.18, -3.02]
GRADE not reported
3 studies · 170 participants

Included primary studies 7

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Abd Elgaleel 2025
matched by author and year (probable)
NRthis review onlyMaximum mouth openingnot extracted yet
Algabri 2017
matched by author and year (probable)
NRthis review onlyPain intensity (VAS); Limited mouth opening; Maximum mouth opening; Mouth opening (limited and maximum combined)not extracted yet
Berntsen 2018
Clinical comparison of conventional and additive manufactured stabilization splints.
PMID:30128331
2018this review onlyPain intensity (VAS); Limited mouth opening; Maximum mouth opening; Mouth opening (limited and maximum combined)not extracted yet
Chen 2026
Application of fully digital occlusal splints in painful temporomandibular disorders: a randomized controlled clinical study.
PMID:41495778
2026this review onlyPain intensity (VAS)not extracted yet
Hussein 2025
matched by author and year (probable)
NRthis review onlyPain intensity (VAS); Limited mouth openingnot extracted yet
Pho Duc 2016
Parallel Randomized Controlled Clinical Trial in Patients with Temporomandibular Disorders Treated with a CAD/CAM Versus a Conventional…
PMID:27479339
2016this review onlyPain intensity (VAS); Limited mouth openingnot extracted yet
Qin 2025
Comparative Efficacy of Digital 3D-Printed and Conventional Stable Occlusal Splints in the Treatment of Temporomandibular Disorders.
PMID:40384555
2025this review onlyPain intensity (VAS); Limited mouth opening; Mouth opening (limited and maximum combined)not extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationPatients diagnosed with temporomandibular disorders (TMD)Patients with TMD (n=390)
InterventionDigitally fabricated occlusal splintsDigital occlusal splints (CAD/CAM milled or 3D printed; intraoral scan and CAD)
ComparisonConventionally fabricated occlusal splintsConventional (heat-cured or self-curing acrylic) occlusal splints
OutcomesPrimary: pain intensity (VAS) at last follow-up; secondary: maximum and limited mouth opening, patient satisfaction (Likert), clinical occlusal adjustment time (T-Scan)Pain (7 studies, n=378), mouth opening (5 studies), satisfaction (4 studies), occlusal adjustment time (3 studies)
Study designsRandomized controlled trials (crossover trials: first period only)RCTs (n=8; six parallel-group, two crossover)
TimingLast available follow-upLast available follow-up

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalNoNoyes
3Choice of study designs explainedYesNono
4Comprehensive literature searchcriticalNoNoyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateNoNoyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: N/ANRSI: N/A · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: Yes · NRSI: N/ANRSI: N/A · RCT: Yesno
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalNoNoyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes