Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
It is very uncertain whether in-office laser therapy (all types combined) changes changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment (very low certainty).
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Er,Cr:YSGG laser (erbium,chromium:yttrium-scandium-gallium-garnet) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Nd:YAG laser (neodymium-doped:yttrium-aluminum-garnet) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Adverse events · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
2 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, visible red (630 nm to 700 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (700 nm to 850 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (850 nm to 980 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (850 nm to 980 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
It is very uncertain whether in-office laser therapy (all types combined) changes changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment (very low certainty).
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Nd:YAG laser (neodymium-doped:yttrium-aluminum-garnet) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Treatment success rate · Patients needing retrograde filling in root canal therapy (orthograde root canal filling or retreatment not possible; periapical surgery…
Mineral trioxide aggregate (MTA) showed no clear difference in success rate at 4 years compared with super ethoxybenzoic acid (Super-EBA); GRADE not reported.
1 finding from 1 review
RR 1.02 [0.93, 1.12]
1 study
GRADE not reported
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (700 nm to 850 nm) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Er:YAG laser (erbium-doped:yttrium-aluminum-garnet) vs Placebo (placebo laser or placebo agent) or no treatment
Outcome not reported · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
The review found no eligible studies for this question.
1 finding from 1 review
Overall success rate · Patients needing retrograde filling in root canal therapy (orthograde root canal filling or retreatment not possible; periapical surgery…
Glass ionomer cement showed no clear difference in success rate at 5 years compared with amalgam; GRADE not reported.
1 finding from 1 review
RR 1.00 [0.84, 1.20]
1 study
GRADE not reported
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, visible red (630 nm to 700 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
CO2 laser (carbon dioxide) vs Placebo (placebo laser or placebo agent) or no treatment
Outcome not reported · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
The review found no eligible studies for this question.
1 finding from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Er,Cr:YSGG laser (erbium,chromium:yttrium-scandium-gallium-garnet) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
1 finding from 1 review
Patient-reported quality of life · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
The review found no eligible studies for this question.
1 finding from 1 review
Success rate (radiographically‐assessed healing of cyst healing based on the Neer/Cole rating system) · Patients needing retrograde filling in root canal therapy (orthograde root canal filling or retreatment not possible; periapical surgery…
Mineral trioxide aggregate (MTA) showed no clear difference in success rate at 2 years compared with intermediate restorative material (IRM); GRADE not reported.
1 finding from 1 review
RR 1.05 [0.92, 1.20]
1 study
GRADE not reported
Caries in primary teeth: dmft (3 years) · general population
Fluoridated milk may leads to lower caries in primary teeth: dmft (3 years) compared with non-fluoridated milk (low certainty).
1 finding from 1 review