ICU length of stay (general intensive care patients) · Mechanically ventilated adults in the intensive care unit
1 finding from 1 review
Duration of mechanical ventilation · Mechanically ventilated adults in the intensive care unit
BIS monitoring showed no clear difference in duration of mechanical ventilation (measured in days) compared with clinical assessment (low certainty).
1 finding from 1 review
Adverse events: Measured as number of patients with adverse events · Mechanically ventilated adults in the intensive care unit
1 finding from 1 review
Death from any cause (secondary outcome 3) · Mechanically ventilated adults in the intensive care unit
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Oxygen desaturation · patients undergoing PSA
Capnography and standard monitoring showed no clear difference in oxygen desaturation compared with standard monitoring (moderate certainty).
1 finding from 1 review
Hypotension · patients undergoing PSA
Capnography and standard monitoring showed no clear difference in hypotension compared with standard monitoring (moderate certainty).
1 finding from 1 review
Emesis, pulmonary aspiration · patients undergoing PSA
Capnography and standard monitoring showed no clear difference in emesis, pulmonary aspiration compared with standard monitoring (moderate certainty).
1 finding from 1 review
Airway interventions · patients undergoing PSA
Capnography and standard monitoring showed no clear difference in airway interventions compared with standard monitoring (moderate certainty).
1 finding from 1 review
Airway interventions adult subgroup analysis (aged ≥ 18 years)h · patients undergoing PSA
Capnography and standard monitoring probably leads to higher airway interventions adult subgroup analysis (aged ≥ 18 years)h compared with standard monitoring (moderate certainty).
1 finding from 1 review
Time to recovery · patients undergoing PSA
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Time to initiation of antimicrobial therapy (Time to initiation starts at the time of admission) · people admitted to intensive care units
It is very uncertain whether automated monitoring systems changes time to initiation of antimicrobial therapy (Time to initiation… compared with standard care (very low certainty).
1 finding from 1 review
Time to initiation of fluid resuscitation (Time to initiation starts at the time of admission) · people admitted to intensive care units
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
30‐day mortality* · people admitted to intensive care units
It is very uncertain whether automated monitoring systems changes 30‐day mortality* compared with standard care (very low certainty).
1 finding from 1 review
no estimate extracted
Studies not reported
Very low
Duration of ICU stay · people admitted to intensive care units
1 finding from 1 review
Failed detection of sepsis (as reported by studies) · people admitted to intensive care units
1 finding from 1 review
Quality of life measured at the latest available time point post‐discharge from ICU (preferred measure SF‐36 then EQ‐5D) · people admitted to intensive care units
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found