Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, fibre-optic transillumination pooled specificity was 0.97 (95% CI 0.89 to 0.994) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Specificity 0.97 [0.89, 0.994]
2 studies
GRADE not reported
DOR 37.77 [13.69, 104.19]
2 studies
GRADE not reported
AUC 0.92
2 studies
GRADE not reported
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, fibre-optic transillumination pooled sensitivity was 0.97 (95% CI -0.92 to 0.99) for occlusal caries at the caries detection level; ungraded.
4 findings from 1 review
Sensitivity 0.97 [-0.92, 0.99]
1 study
GRADE not reported
AUC 0.92
1 study
GRADE not reported
DOR 38.33 [10.15, 144.77]
1 study
GRADE not reported
Show 1 more finding
detection of proximal caries · Permanent posterior teeth, proximal surfaces (in vitro extracted teeth and in vivo patients)
For fibre-optic transillumination (FOTI), studies were identified (in vitro N=4, in vivo N=3) but none had sufficiently low risk of bias and adequate reporting to be pooled; no meta-analytic estimate could be derived.
1 finding from 1 review
no estimate extracted
0 studies
No studies found
Patient satisfaction (measured by patient satisfaction or aesthetic scales) · People who had received fixed appliance orthodontic treatment
It is very uncertain whether fibre-reinforced composite fixed (bonded) retainer changes patient satisfaction: aesthetics (VAS 0-10 cm, lower arch) compared with multistrand / spiral wire fixed (bonded) retainer (very low certainty).
1 finding from 1 review
Survival of retainers (failure, lower arch) · People who had received fixed appliance orthodontic treatment
Fibre-reinforced composite fixed (bonded) retainer showed no clear difference in survival of retainers (failure, lower arch) compared with multistrand / spiral wire fixed (bonded) retainer (low certainty).
1 finding from 1 review
Adverse effects on oral health: bleeding on probing (lower arch) · People who had received fixed appliance orthodontic treatment
The review found no eligible studies for this question.
1 finding from 1 review
Survival: mean survival time (lower arch, months) · People who had received fixed appliance orthodontic treatment
The review found no eligible studies for this question.
1 finding from 1 review
Stability: Little's Irregularity Index (lower arch) · People who had received fixed appliance orthodontic treatment
It is very uncertain whether fibre-reinforced composite fixed (bonded) retainer changes stability: Little's Irregularity Index (lower arch) compared with multistrand / spiral wire fixed (bonded) retainer (very low certainty).
1 finding from 1 review
Adverse effects on oral health: Gingival Index (lower arch) · People who had received fixed appliance orthodontic treatment
The review found no eligible studies for this question.
1 finding from 1 review
Clinical/technical failure (root fracture) · Participants with permanent endodontically-treated (root-filled) teeth for which a post is indicated to retain the final restoration
Non-metal carbon-fibre post and core (Category III; Composipost) led to lower clinical/technical failure (root fracture) compared with metal custom-cast post and core (Category I; gold alloy); GRADE not reported.
1 finding from 1 review
Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review
Fibre-optic transillumination (FOTI, including white light scattering and near infrared) vs Reference standard: histology or enhanced visual-tactile examination
Outcome not reported · Adults presenting asymptomatically or suspected of having root caries (in vivo); extracted teeth of adults (in vitro)
The review found no eligible studies for this question.
1 finding from 1 review
Treatment failure (annual failure rate) · Children with severely decayed maxillary primary incisors treated by pulpectomy (non-vital pulp therapy)
Composite strip crowns with composite posts had a low annual failure rate (2.3%) in maxillary primary incisors after pulpectomy (single high-risk-of-bias RCT; low quality of evidence; not GRADE-rated).
3 findings from 1 review
AFR 2.3
1 study · 54 participants
GRADE not reported
AFR 2.2
1 study · 54 participants
GRADE not reported
AFR 0
1 study · 54 participants
GRADE not reported
Change in probing pocket depth (PPD) · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Complications and side effects · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Implant failure · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Recurrence of peri-implantitis · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Radiographic marginal bone level · People with at least one dental implant affected by perimplantitis
1 finding from 1 review
Clinical failure (post dislodgement) · Participants with endodontically-treated permanent premolars restored with a carbon-fibre post (Category III)
Direct composite restoration (final restoration) showed no clear difference in clinical failure (post dislodgement) compared with full-coverage metal-ceramic crown; GRADE not reported.
1 finding from 1 review