Pain during laser treatment ‐ not reported · proliferative diabetic retinopathy
Diode laser probably leads to higher pain during laser treatment compared with argon laser (moderate certainty).
1 finding from 1 review
Progression of PDR · proliferative diabetic retinopathy
It is very uncertain whether diode laser changes progression of PDR compared with argon laser (very low certainty).
1 finding from 1 review
Regression of PDR · proliferative diabetic retinopathy
It is very uncertain whether diode laser changes regression of PDR compared with argon laser (very low certainty).
1 finding from 1 review
Vision‐related QoL ‐ not reported · proliferative diabetic retinopathy
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Adverse events · proliferative diabetic retinopathy
It is very uncertain whether diode laser changes adverse events compared with argon laser (very low certainty).
1 finding from 1 review
BCVA: loss of 15 or more ETDRS letters · proliferative diabetic retinopathy
It is very uncertain whether diode laser changes BCVA: loss of 15 or more ETDRS letters compared with argon laser (very low certainty).
1 finding from 1 review
BCVA: gain of 15 or more ETDRS letters · proliferative diabetic retinopathy
It is very uncertain whether diode laser changes BCVA: gain of 15 or more ETDRS letters compared with argon laser (very low certainty).
1 finding from 1 review
Clinical failure · Children with extensive decay involving the dental pulp in primary teeth
It is very uncertain whether diode laser changes clinical failure compared with electrosurgery (very low certainty).
1 finding from 1 review
Radiological failure · Children with extensive decay involving the dental pulp in primary teeth
Diode laser showed no clear difference in radiological failure compared with ferric sulphate (FS) (low certainty).
1 finding from 1 review
Clinical failure · Children with extensive decay involving the dental pulp in primary teeth
Diode laser showed no clear difference in clinical failure compared with ferric sulphate (FS) (low certainty).
1 finding from 1 review
Radiological failure · Children with extensive decay involving the dental pulp in primary teeth
Diode laser showed no clear difference in radiological failure compared with formocresol (FC); GRADE not reported.
1 finding from 1 review
Clinical failure · Children with extensive decay involving the dental pulp in primary teeth
Diode laser showed no clear difference in clinical failure compared with formocresol (FC); GRADE not reported.
1 finding from 1 review
Radiological failure · Children with extensive decay involving the dental pulp in primary teeth
Diode laser showed no clear difference in radiological failure compared with electrosurgery (low certainty).
1 finding from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, visible red (630 nm to 700 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, visible red (630 nm to 700 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (700 nm to 850 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
3 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through air blast stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (850 nm to 980 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through air blast… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (850 nm to 980 nm) led to lower changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Changes in intensity of pain (VAS 0 to 10) tested through tactile stimuli · Patients aged above 12 years with self-reported tooth hypersensitivity confirmed on clinical evaluation
Diode laser, near infrared (700 nm to 850 nm) showed no clear difference in changes in intensity of pain (VAS 0 to 10) tested through tactile… compared with placebo (placebo laser or placebo agent) or no treatment; GRADE not reported.
2 findings from 1 review
Patient-reported altered sensation (spontaneous or evoked: anaesthesia/paraesthesia/dysaesthesia/hyperalgesia/allodynia) · Patients of any age in any setting requiring intervention for iatrogenic injury to the inferior alveolar or lingual nerve
It is very uncertain whether low-level laser therapy (photon-plus GaAlAs diode laser; 70 mW… changes patient-reported altered sensation (spontaneous or evoked:… compared with placebo (sham) laser therapy (very low certainty).
2 findings from 1 review