Abnormal FHR as defined by trial authors (FHR tracing not improved) · women for whom a decision had been made to deliver by caesarean section for suspected fetal distress based on FHR monitoring
Summary of findings for IV hexoprenaline probably leads to lower FHR tracing not improved compared with no tocolytic agent, whilst awaiting emergency delivery (moderate certainty).
1 finding from 1 review
Proportion of patients who have no AOM recurrences at 6 months post‐randomisation
Grommets may leads to higher proportion of patients who have no AOM recurrences at 6 months… compared with active monitoring (low certainty).
1 finding from 1 review
Persistent tympanic membrane perforation
1 finding from 1 review
Proportion of patients who have no AOM recurrences at 12 months post‐randomisation
Grommets showed no clear difference in proportion of patients who have no AOM recurrences at 12 months… compared with active monitoring (low certainty).
1 finding from 1 review
Total number of AOM recurrences at 6 months post‐randomisation
Grommets showed no clear difference in total number of AOM recurrences at 6 months post‐randomisation compared with active monitoring (low certainty).
1 finding from 1 review
Total number of AOM recurrences at 12 months post‐randomisation
1 finding from 1 review
Disease‐specific quality of life
1 finding from 1 review
Awareness Postoperative interview · patients with prevention of recall of events during surgery
Anaesthesia depth monitors (BIS and M‐entropy) showed no clear difference in awareness Postoperative interview compared with standard clinical and electronic monitoring (low certainty).
1 finding from 1 review
Adverse effects of intraoperative wakefulness and/or postoperative awareness (i.e. post‐traumatic stress syndrome, myocardial infarction, cardiac arrest, etc.) · patients with prevention of recall of events during surgery
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Awareness: definite and possible Postoperative interview · patients with prevention of recall of events during surgery
Anaesthesia depth monitors (BIS) showed no clear difference in awareness: definite and possible Postoperative interview compared with standard clinical and electronic monitoring (low certainty).
1 finding from 1 review
Awareness: definite Postoperative interview · patients with prevention of recall of events during surgery
Anaesthesia depth monitors (BIS) showed no clear difference in awareness: definite Postoperative interview compared with standard clinical and electronic monitoring (low certainty).
1 finding from 1 review
Adverse effects of intraoperative wakefulness and/or postoperative awareness (i.e. post‐traumatic stress syndrome, myocardial infarction, cardiac arrest, etc.) · patients with prevention of recall of events during surgery
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Access thrombosis/vascular complication · people receiving haemodialysis to treat kidney failure and using a functioning AV access for haemodialysis.
Scheduled surveillance showed no clear difference in risk of access thrombosis compared with clinical monitoring alone (moderate certainty).
1 finding from 1 review
Rate of angiograms · people receiving haemodialysis to treat kidney failure and using a functioning AV access for haemodialysis.
Scheduled surveillance may leads to higher rate of angiograms compared with clinical monitoring alone (low certainty).
1 finding from 1 review
Risk of access loss · people receiving haemodialysis to treat kidney failure and using a functioning AV access for haemodialysis.
Scheduled surveillance showed no clear difference in risk of access loss compared with clinical monitoring alone (moderate certainty).
1 finding from 1 review
All‐cause mortality · people receiving haemodialysis to treat kidney failure and using a functioning AV access for haemodialysis.
Scheduled surveillance showed no clear difference in mortality compared with clinical monitoring alone (low certainty).
1 finding from 1 review
Adherence to inhaled therapies cMPR · children aged 5 to 16 years
Digital technology (TIM) may leads to higher adherence to the inhaled treatment: compared with standard treatment (TBM) (low certainty).
1 finding from 1 review
Pulmonary exacerbations · adults (aged 16 years and over) with CF
Digital technology (web‐based platform CFHealthHub) probably leads to lower number of pulmonary exacerbations compared with usual care (moderate certainty).
1 finding from 1 review
Treatment burden · children aged 5 to 16 years
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
QoL · children aged 5 to 16 years
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found