Reintervention (due to technical failure) · people requiring intervention for short saphenous vein varices
1 finding from 1 review
Disease‐specific quality of life · people requiring intervention for short saphenous vein varices
2 findings from 1 review
Complications at 1 year · people requiring intervention for short saphenous vein varices
1 finding from 1 review
Recurrence of reflux at 1 year · people requiring intervention for short saphenous vein varices
Endovenous laser ablation may leads to lower recurrence of reflux at 1 year compared with conventional surgery (low certainty).
1 finding from 1 review
Recurrence · people requiring intervention for short saphenous vein varices
Endovenous laser ablation showed no clear difference in clinical evidence of recurrence after 1 year compared with conventional surgery (low certainty).
1 finding from 1 review
Reintervention (due to technical failure) · people requiring intervention for short saphenous vein varices
1 finding from 1 review
Disease‐specific quality of life · people requiring intervention for short saphenous vein varices
2 findings from 1 review
Complications at 6 weeks · people requiring intervention for short saphenous vein varices
1 finding from 1 review
Recanalisation or persistence of reflux at 6 weeks · people requiring intervention for short saphenous vein varices
Ultrasound‐guided foam sclerotherapy showed no clear difference in recanalisation or persistence of reflux at 6 weeks compared with conventional surgery (low certainty).
1 finding from 1 review
Recurrence of reflux at 1 year · people requiring intervention for short saphenous vein varices
Ultrasound‐guided foam sclerotherapy showed no clear difference in recurrence of reflux at 1 year compared with conventional surgery (low certainty).
1 finding from 1 review
Amputation · people with peripheral arterial disease of the lower limbs
Drug‐eluting balloon showed no clear difference in amputation compared with uncoated balloon angioplasty at 12 months (high certainty).
1 finding from 1 review
Primary vessel patency · people with peripheral arterial disease of the lower limbs
Drug‐eluting balloon leads to higher primary vessel patency compared with uncoated balloon angioplasty at 12 months (high certainty).
1 finding from 1 review
Target lesion revascularization · people with peripheral arterial disease of the lower limbs
Drug‐eluting balloon may leads to lower target lesion revascularization compared with uncoated balloon angioplasty at 12 months (low certainty).
1 finding from 1 review
Binary restenosis · people with peripheral arterial disease of the lower limbs
Drug‐eluting balloon probably leads to lower binary restenosis compared with uncoated balloon angioplasty at 12 months (moderate certainty).
1 finding from 1 review
Death · people with peripheral arterial disease of the lower limbs
Drug‐eluting balloon showed no clear difference in death compared with uncoated balloon angioplasty at 12 months (high certainty).
1 finding from 1 review
Change in Rutherford category · people with peripheral arterial disease of the lower limbs
1 finding from 1 review
Change in ankle‐brachial index · people with peripheral arterial disease of the lower limbs
1 finding from 1 review
Intervention not reported
Incidence of recurrent VTE · patients with venous thromboembolism
The intervention leads to lower incidence of recurrent VTE (high certainty).
1 finding from 1 review
Intervention not reported
Incidence of major bleeding · patients with venous thromboembolism
The intervention probably leads to higher incidence of major bleeding (moderate certainty).
1 finding from 1 review
Intervention not reported
Mortality · patients with venous thromboembolism
The intervention showed no clear difference in mortality (moderate certainty).
1 finding from 1 review