Cochrane · systematic review · CD011319

Drug‐eluting balloon angioplasty versus uncoated balloon angioplasty for peripheral arterial disease of the lower limbs

Kayssi, A, Al‐Atassi, T, Oreopoulos, G, et al. · Cochrane Database of Systematic Reviews · 2016 · Cochrane Library

VascularAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
7
current version
GRADE rated
7
No studies
0
Included studies
NR
No studies 0 · 0%Ungraded 0 · 0%Very low 0 · 0%Low 1 · 14.3%Moderate 2 · 28.6%High 4 · 57.1%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Drug‐eluting balloon versus uncoated balloon angioplasty at 12 months

Population: people with peripheral arterial disease of the lower limbs
7 questions
OutcomeEffectEvidenceStatus / GRADE
Amputation
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
OR 1.56 [0.73, 3.33]9 studies · 1649 participantsHigh
Primary vessel patency
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
OR 1.92 [1.45, 2.56]3 studies · 882 participantsHigh
Target lesion revascularization
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
OR 0.4 [0.31, 0.51]11 studies · 1900 participantsLow
Downgraded: risk of bias, inconsistency, publication bias
Binary restenosis
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
OR 0.38 [0.15, 0.98]4 studies · 1094 participantsModerate
Downgraded: risk of bias, inconsistency
Death
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
OR 1.09 [0.64, 1.85]9 studies · 1649 participantsHigh
Change in Rutherford category
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
no estimate extracted3 studies · 623 participantsModerate
Downgraded: risk of bias, inconsistency
Change in ankle‐brachial index
Drug‐eluting balloon vs uncoated balloon angioplasty at 12 months
no estimate extracted3 studies · 656 participantsHigh