Non-Cochrane · intervention · PM41531572

The Clinical Impact of Dental Implant Placement in Close Proximity to Natural Teeth: A Systematic Review and Meta-Analysis.

Joshi Nilesh V, Rao Prajakta, Talreja Prakash, et al. · Cureus · 2025 · PubMed · doi:10.7759/cureus.99077

Findings

Population Patients with dental implants placed to replace missing teeth in either jaw

7 findings

Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceMarginal bone loss and peri-implantitis
Follow-up 6 to 75 months · Dental implant surgery and follow-up
no estimate extracted
Moderate
Downgraded: imprecision, inconsistency
4 studies
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceAny proximity-related clinical or radiographic complication (composite)
Follow-up 6 to 75 months · Dental implant surgery and follow-up
Proportion 0.12 [0.05, 0.22]
Low
Downgraded: imprecision, inconsistency
8 studies · 1898 participants
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceImplants showing any proximity-related clinical or radiographic alteration
Follow-up 6 to 75 months · Dental implant surgery and follow-up
Proportion (text-reported) 0.58 [0.55, 0.62]
Low
Downgraded: imprecision, inconsistency
Studies not reported
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceCaries and structural damage of adjacent teeth
Follow-up 6 to 75 months · Dental implant surgery and follow-up
no estimate extracted
Low
Downgraded: imprecision, inconsistency, publication bias
3 studies
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distancePulpal and periapical pathology in adjacent teeth
Follow-up 6 to 75 months · Dental implant surgery and follow-up
no estimate extracted
Moderate
Downgraded: imprecision, inconsistency
5 studies
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceImplant survival in close proximity to teeth
Follow-up 6 to 75 months · Dental implant surgery and follow-up
no estimate extracted
High
4 studies
Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants placed at or beyond the recommended 1.5 mm distanceAny proximity-related clinical or radiographic complication (composite)
Follow-up 6 to 75 months · Dental implant surgery and follow-up
Unresolved: the two extractors disagree on this row.
Effect size (as reported) 0.11 [0.03, 0.22]
Low
Downgraded: imprecision, inconsistency
Studies not reported

Included primary studies 11

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Clark 2017
Incidental findings of implant complications on postimplantation CBCTs: A cross‐sectional study
DOI:10.1111/cid.12511
2017this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Davarpanah 2009
Unconventional implant treatment: I. Implant placement in contact with ankylosed root fragments. A series of five case reports
DOI:10.1111/j.1600-0501.2008.01653.x
2009this review onlynot statednot extracted yet
Hamdoon 2021
The consequences and outcomes associated with dental implants encroaching on adjacent teeth
DOI:10.1111/cid.13047
2021this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Kucukkurt 2022
Survival Rates of Implants That Have Compromised the Adjacent Teeth and the Associated Complications: An Opg Retrospective Study
DOI:10.1563/aaid-joi-d-20-00263
2022this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Margelos 1995
Irreversible pulpal damage of teeth adjacent to recently placed osseointegrated implants
DOI:10.1016/s0099-2399(06)81533-5
1995this review onlynot statednot extracted yet
Ng 2018
Peri‐implant inflammation and marginal bone level changes around dental implants in relation to proximity with and bone level of adjacent…
DOI:10.1111/adj.12650
2018this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Smith 2020
Influence of Implant-Tooth Proximity on Incidence of Caries in Teeth Adjacent to Implants in Molar Sites: A Retrospective Radiographic…
PMID:31904245
2020this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Tagger-Green 2023
Effect of posterior implant restorations on adjacent teeth and tissues: A case–control study
DOI:10.1111/cid.13207
2023this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Tasharoie 2015
matched by author and year (probable)
NRthis review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Yi 2021
Long term clinical result of implant induced injury on the adjacent tooth
DOI:10.1038/s41598-021-87062-9
2021this review onlyAny proximity-related clinical or radiographic complication (composite)not extracted yet
Yoon 2013
Prognosis and evaluation of tooth damage caused by implant fixtures.
PMID:24471033
2013this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationPatients who underwent dental implant placement for replacement of missing teeth in either jawPatients with implants close to natural teeth (n=1,727 participants; over 2,000 implants)
InterventionImplants positioned within 1.5 mm of an adjacent natural tooth or in direct contact with the root surfaceImplants less than 1.5 mm from adjacent roots or in direct contact (n=11 studies)
ComparisonImplants placed at or beyond the recommended 1.5 mm distanceNo eligible comparison group in most studies; pooled proportions only
OutcomesAdjacent tooth damage, peri-implant bone changes, implant failure; pulpal or periodontal complications and endodontic interventionPulpal or periapical pathology (n=5), marginal bone loss or peri-implantitis (n=4), caries or structural damage (n=3), implant survival (n=4), composite any proximity-related complication (n=8)
Study designsObservational studies, case-control, cohort, cross-sectional studies and case series8 observational studies and 3 case series (n=11)
TimingNot specifiedFollow-up 3 to 75 months

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalNoPartial Yesno
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: N/A · NRSI: Partial YesRCT: N/A · NRSI: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: N/A · NRSI: NoRCT: N/A · NRSI: Noyes
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalYesYesyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes