Primary study · included by 1 review
Peri‐implant inflammation and marginal bone level changes around dental implants in relation to proximity with and bone level of adjacent teeth
Ng 2018 · Ng KT, Fan MHM, Leung MC, et al. · Australian Dental Journal · 2018
Included by
| Outcome this study informs | Pooled effect | Evidence | Certainty |
|---|---|---|---|
Any proximity-related clinical or radiographic complication (composite) Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surface vs Implants placed at or beyond the recommended 1.5 mm distance · Follow-up 6 to 75 months | Proportion 0.12 [0.05, 0.22] | 8 studies · 1898 participants | Low |
Implants showing any proximity-related clinical or radiographic alteration Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surface vs Implants placed at or beyond the recommended 1.5 mm distance · Follow-up 6 to 75 months | Proportion (text-reported) 0.58 [0.55, 0.62] | NR | Low |
Any proximity-related clinical or radiographic complication (composite) Implants placed within 1.5 mm of an adjacent natural tooth or in direct contact with the root surface vs Implants placed at or beyond the recommended 1.5 mm distance · Follow-up 6 to 75 months | Effect size (as reported) 0.11 [0.03, 0.22] | NR | Low |
1 including review in total.