The clinical effects of laser preparation of tooth surfaces for fissure sealants placement: a systematic review and meta-analysis.
Zhang Yunhan, Wang Yan, Chen Yandi, et al. · BMC oral health · 2019 · PubMed · doi:10.1186/s12903-019-0892-4
Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.
Review question
| Element | Planned (methods) | Found (results) |
|---|---|---|
| Population | Caries-free patients with untreated premolars and/or molars and/or primary molars suitable for pit-and-fissure sealing | Caries-free children to young adults (5 studies; ages 6-38 y; 16-64 subjects per study) |
| Intervention | Lasers as a pretreatment (enamel conditioning) method for pit-and-fissure sealing | Lasers: Er,Cr:YSGG (n=2), Er:YAG combined with acid-etching (n=2), carbon dioxide (n=1) |
| Comparison | Any other mechanical or chemical preparation (e.g., acid-etching, enameloplasty, air abrasion) | Acid-etching (phosphoric acid) in all 5 studies |
| Outcomes | Sealant retention rate; incidence of dental caries; adverse events; clinical time; patient acceptability; anxiety | Retention rate (n=4); incidence of caries (n=2); patient acceptability (n=1); dental anxiety, heart rate, oxygen saturation (n=1); adverse events (none reported, n=5) |
| Study designs | Randomized clinical trials (RCTs) | RCTs (n=5; 3 split-mouth, 2 parallel-design) |
| Timing | Not specified | Follow-up 3-36 months; meta-analysis at 3, 6, 9, 12, 18 and 24 months |
Search date: January 2019. Databases: PubMed, Scopus, Medline/EMBASE via OVID, Cochrane Library; ClinicalTrials.gov and ISRCTN trial registries; OpenGrey grey literature; reference lists of included studies (hand-search)
Questions and results
Laser enamel preparation alone (Er,Cr:YSGG or CO2 laser) vs Acid-etching (phosphoric acid)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Sealant retention rate (completely retained) 18 months At 18 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 0.82, 95% CI 0.23 to 2.85; ungraded, single study, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 0.82 [0.23, 2.85] | 1 study · 16 participants | Ungraded |
Sealant retention rate (completely retained) 12 months At 12 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 1.05, 95% CI 0.61 to 1.80; ungraded, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 1.05 [0.61, 1.80] | 3 studies · 73 participants | Ungraded |
Patient acceptability (VAS discomfort) Both laser and acid-etching preparation were well accepted by patients (VAS, P = 1.000; ungraded, single study). Source: Results 'Patient satisfaction'; Table 1 · same question in other reviews | Kumar 2016 (Er,Cr:YSGG laser vs acid-etching): patient acceptance scored on a visual analogue scale; both preparations well accepted, P = 1.000; no significant difference. | 1 study · 50 participants | Ungraded |
Sealant retention rate (completely retained) 6 months At 6 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 1.22, 95% CI 0.69 to 2.16; ungraded, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 1.22 [0.69, 2.16] | 3 studies · 80 participants | Ungraded |
Clinical (chair-side) time Laser conditioning was reported to take less chair-side time than acid-etching in the studies that measured it, but times were not pooled (ungraded, narrative). Source: Results 'Clinical time' · same question in other reviews | Walsh 1996 reported laser conditioning time of 7 s vs 70 s for acid preparation; Kumar 2016 reported Er,Cr:YSGG exposure ~10 s vs >35 s for acid etching; laser conditioning was shorter but times were not pooled, and… | 2 studies | Ungraded |
Incidence of dental caries 24 months In the single study reporting it, caries incidence was 0% in both the laser-alone and acid-etching groups (ungraded, single study). Source: Results 'Incidence of caries' · same question in other reviews | Karaman 2013 (Er,Cr:YSGG laser vs acid-etching): incidence of caries was 0% in both groups; not meta-analyzed. | 1 study · 16 participants | Ungraded |
Sealant retention rate (completely retained) 3 months At 3 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 2.78, 95% CI 0.87 to 8.91; ungraded, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 2.78 [0.87, 8.91] | 2 studies · 65 participants | Ungraded |
Adverse events No adverse events were reported in any included study (ungraded, narrative). Source: Results 'Adverse events' · same question in other reviews | No adverse events (pulpal sensation, post-lasing thermal sensitivity, pulpitis, or other laser-induced pathology) were reported in any of the included studies. | 5 studies | Ungraded |
Sealant retention rate (completely retained) 9 months At 9 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 1.15, 95% CI 0.63 to 2.10; ungraded, single study, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 1.15 [0.63, 2.10] | 1 study · 43 participants | Ungraded |
Sealant retention rate (completely retained) 24 months At 24 months, laser preparation alone did not differ significantly from acid-etching for sealant retention (OR 0.87, 95% CI 0.31 to 2.45; ungraded, single study, high risk of bias). Source: Results 'Retention rate'; Fig. 4 · same question in other reviews | OR 0.87 [0.31, 2.45] | 1 study · 16 participants | Ungraded |
Er:YAG laser preparation combined with acid-etching vs Acid-etching (phosphoric acid) alone
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Sealant retention rate (completely retained) 6 months At 6 months, adding Er:YAG laser to acid-etching did not significantly change sealant retention versus acid-etching alone (OR 0.55, 95% CI 0.23 to 1.34; ungraded, single study). Source: Results 'Retention rate'; Discussion 'Laser combined with acid preparation'; Fig. 5 · same question in other reviews | OR 0.55 [0.23, 1.34] | 1 study · 42 participants | Ungraded |
Sealant retention rate (completely retained) 18 months At 18 months, Er:YAG laser combined with acid-etching significantly improved sealant retention versus acid-etching alone (OR 0.41, 95% CI 0.21 to 0.80, favouring laser+acid; ungraded, single study). Source: Results 'Retention rate'; Discussion 'Laser combined with acid preparation'; Fig. 5 · same question in other reviews | OR 0.41 [0.21, 0.80] | 1 study · 42 participants | Ungraded |
Sealant retention rate (completely retained) 12 months At 12 months, Er:YAG laser combined with acid-etching significantly improved sealant retention versus acid-etching alone (OR 0.39, 95% CI 0.19 to 0.80, favouring laser+acid; ungraded, single study). Source: Results 'Retention rate'; Discussion 'Laser combined with acid preparation'; Fig. 5 · same question in other reviews | OR 0.39 [0.19, 0.80] | 1 study · 42 participants | Ungraded |
Physiological stress indicators (heart rate, oxygen saturation) Population: Children (ages 6-12) receiving pit-and-fissure sealants Heart rate and oxygen saturation did not differ significantly between laser-plus-acid and acid-etching (ungraded, single study). Source: Results 'Patient satisfaction' · same question in other reviews | Shindova 2018 (Er:YAG laser+acid vs acid-etching): no significant differences in heart rate or oxygen saturation between groups. | 1 study · 64 participants | Ungraded |
Incidence of dental caries 18 months Population: Children (high caries risk) with permanent molars requiring pit-and-fissure sealants Caries incidence was 10% with laser-plus-acid versus 22% with acid-etching at 18 months, a non-significant difference (ungraded, single study). Source: Results 'Incidence of caries'; Discussion 'Laser combined with acid preparation' · same question in other reviews | Durmus 2017 (Er:YAG laser+acid vs acid-etching): caries incidence 10% (n=8) in the laser-plus-acid group vs 22% (n=18) in the acid-etching group at 18 months; difference not statistically significant (P > 0.05). | 1 study · 51 participants | Ungraded |
Dental anxiety (subjective and objective scores) Population: Children (ages 6-12) receiving pit-and-fissure sealants Er:YAG laser preparation added to acid-etching did not increase children's dental anxiety versus acid-etching alone (P > 0.05; ungraded, single study). Source: Results 'Patient satisfaction'; Table 1 · same question in other reviews | Shindova 2018 (Er:YAG laser+acid vs acid-etching): no significant difference between initial and final subjective anxiety scores for the two groups; use of the Er:YAG laser did not provoke anxiety (P > 0.05). | 1 study · 64 participants | Ungraded |
Sealant retention rate (completely retained) 3 months At 3 months, adding Er:YAG laser to acid-etching did not significantly change sealant retention versus acid-etching alone (OR 0.47, 95% CI 0.14 to 1.64; ungraded, single study). Source: Results 'Retention rate'; Discussion 'Laser combined with acid preparation'; Fig. 5 · same question in other reviews | OR 0.47 [0.14, 1.64] | 1 study · 42 participants | Ungraded |
Laser enamel preparation vs Enameloplasty
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Any planned outcome (sealant retention, caries, etc.) No eligible studies compared laser preparation with enameloplasty for fissure sealant placement (evidence gap). Source: Focused question (comparators); Discussion 'Effects of study methodology on outcome' (shortcomings) · same question in other reviews | no estimate extracted | 0 studies | No studies |
Laser enamel preparation vs Air abrasion
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Any planned outcome (sealant retention, caries, etc.) No eligible studies compared laser preparation with air abrasion for fissure sealant placement (evidence gap). Source: Focused question (comparators); Discussion 'Effects of study methodology on outcome' (shortcomings) · same question in other reviews | no estimate extracted | 0 studies | No studies |
AMSTAR 2 appraisal
Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.
| Item | Extractor A | Extractor B | Agree |
|---|---|---|---|
| 1Research question includes PICO components | Yes | Yes | yes |
| 2Protocol established before the reviewcritical | No | No | yes |
| 3Choice of study designs explained | No | Yes | no |
| 4Comprehensive literature searchcritical | Partial Yes | Partial Yes | yes |
| 5Study selection in duplicate | Yes | Yes | yes |
| 6Data extraction in duplicate | Yes | Yes | yes |
| 7List of excluded studies with reasonscritical | No | No | yes |
| 8Included studies described in detail | Yes | Yes | yes |
| 9Risk of bias assessed satisfactorilycritical | NRSI: N/A · RCT: Yes | RCT: Yes | no |
| 10Funding of included studies reported | No | No | yes |
| 11Appropriate meta-analysis methodscritical | NRSI: N/A · RCT: Yes | RCT: No | no |
| 12Impact of risk of bias on the pooled results | No | No | yes |
| 13Risk of bias accounted for in interpretationcritical | Yes | Yes | yes |
| 14Heterogeneity explained | Yes | N/A | no |
| 15Publication bias investigatedcritical | No | N/A | no |
| 16Conflicts of interest reported | Yes | Yes | yes |
| Overall | Critically Low | Critically Low | yes |
Included primary studies 5
Open as a trial list| Study | Also included by | Outcomes it informs here | Trial PICO | Results |
|---|---|---|---|---|
| Durmus 2017 DOI:10.3290/j.ohpd.a37927 | this review only | Sealant retention rate (completely retained) | not extracted yet | not extracted yet |
| Karaman 2013 Comparison of Acid Versus Laser Etching on the Clinical Performance of a Fissure Sealant: 24-Month Results DOI:10.2341/11-435-c | this review only | Sealant retention rate (completely retained) | not extracted yet | not extracted yet |
| Kumar 2016 A comparative evaluation of retention of pit and fissure sealants placed with conventional acid etching and Er,Cr:YSGG laser etching: A… PMID:28765674 | this review only | Sealant retention rate (completely retained) | not extracted yet | not extracted yet |
| Shindova 2018 Influence of Er:YAG Laser on Objective and Subjective Parameters of Stress during Sealant Application in Children DOI:10.1515/folmed-2017-0086 | this review only | Dental anxiety (subjective and objective scores) | not extracted yet | not extracted yet |
| Walsh 1996 Split‐mouth study of sealant retention with carbon dioxide laser versus acid etch conditioning DOI:10.1111/j.1834-7819.1996.tb05925.x | this review only | Sealant retention rate (completely retained) | not extracted yet | not extracted yet |