Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

11 questions · 12 findings · 2 reviews · Incontinence

No studies found 0 · 0%GRADE not reported 0 · 0%Very low 1 · 8.3%Low 6 · 50%Moderate 2 · 16.7%High 3 · 25%

Silver alloyed catheter vs silicone catheter

urinary tract infections Bacterial biofilm on the surfaces of catheters. UTI was defined as uropathogenic colonisation of urinary catheter. · patients with long‐term bladder drainage in adults

Silver alloyed catheter showed no clear difference in urinary tract infections Bacterial biofilm on the surfaces of… compared with silicone catheter (low certainty).

1 finding from 1 review

Impregnated catheters vs antiseptic‐coated catheter

Symptomatic CAUTI: without microbiological evidence ‐ antibiotic versus silver alloy · Patients with an indwelling urethral catheter of short‐term duration

Antimicrobial‐impregnated catheter showed no clear difference in symptomatic CAUTI: without microbiological evidence ‐ antibiotic… compared with antiseptic‐coated catheter (moderate certainty).

1 finding from 1 review

Impregnated catheters vs antiseptic‐coated catheter

Symptomatic CAUTI: with microbiological evidence ‐ antibiotic versus silver alloy · Patients with an indwelling urethral catheter of short‐term duration

Antimicrobial‐impregnated catheter leads to lower symptomatic CAUTI: with microbiological evidence ‐ antibiotic versus… compared with antiseptic‐coated catheter (high certainty).

1 finding from 1 review

Antispetic‐coated catheter vs standard catheter

Patient discomfort whilst catheter is in situ · Patients with an indwelling urethral catheter of short‐term duration
2 findings from 1 review