Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

62 questions · 102 findings · 5 reviews · Dental caries

No studies found 10 · 9.8%GRADE not reported 82 · 80.4%Very low 3 · 2.9%Low 7 · 6.9%Moderate 0 · 0%High 0 · 0%

All fluorescence-based devices (red, blue, and green fluorescence combined) vs Reference standard (histology, excavation, or enhanced visual examination)

Diagnostic odds ratio (DOR) by subgroup: Enhanced visual examination reference standard (detection of early enamel caries, D1 threshold) · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Analogue (conventional) radiographs vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Radiographic imaging methods (any: analogue radiographs, digital radiographs, or CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
17 findings from 1 review
Show 14 more findings

Cone beam computed tomography (CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
3 findings from 1 review

Near-infrared (NIR) transillumination vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
2 findings from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies) · Permanent dentition
    Permanent dentition (4 studies): sensitivity ranged from 0.55 to 0.65.
    4 studies
    GRADE not reported
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies) · Primary dentition
    Primary dentition (3 studies): sensitivity ranged from 0.91 to 0.93. No evidence of a difference in accuracy by dentition (removing accuracy covariate: Chi2=3.15, df=1, P=0.08).
    3 studies
    GRADE not reported

Radiographic imaging methods (any: analogue radiographs, digital radiographs, or CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
17 findings from 1 review
Show 14 more findings

CarieScan Pro device vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    CarieScan Pro (3 studies, 244 tooth surfaces): sensitivity ranged from 0.55 to 0.91. No evidence of a difference in accuracy by device type (Chi2=0.05, df=1, P=0.82).
    3 studies
    GRADE not reported

Analogue (conventional) radiographs vs Digital radiographs (direct within-person / paired comparison); reference standard: histology, excavation, or enhanced visual examination

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
2 findings from 1 review

Analogue (conventional) radiographs vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Fibre-optic transillumination (FOTI) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard: histology or enhanced visual examination (with or without radiographs)

Outcome not reported · Children/adolescents/adults or extracted teeth; target condition = non-cavitated enamel caries on SMOOTH tooth surfaces.

The review found no eligible studies for this question.

1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    No eligible studies. All included studies assessed occlusal surfaces only; smooth surfaces were a planned surface subgroup with no data.
    0 studies
    No studies found

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
2 findings from 1 review

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection of enamel caries · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    SoF findings (HSROC; no summary operating point reported): 'ECM: sensitivity from 0.61 to 0.98 ... CarieScan Pro: sensitivity from 0.55 to 0.91'. Across all 7 studies (8 datasets), covering 719 tooth surfaces or sites…
    7 studies
    Very low

Electronic caries monitor (ECM) device (ECM II / ECM III / ECM IV) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    ECM (4 studies, 475 tooth surfaces): sensitivity ranged from 0.61 to 0.98 (0.61-0.65 in three studies; 0.98 in the most recent ECM IV study). No evidence of a difference in accuracy by device type (Chi2=0.05, df=1,…
    4 studies
    GRADE not reported

Transillumination and optical coherence tomography devices (all illumination devices combined: NIR, OCT, and FOTI/DIFOTI) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Cone beam computed tomography (CBCT) vs Reference standard (histology, excavation, or enhanced visual examination)

Sensitivity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
3 findings from 1 review

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity for detection of enamel caries · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    SoF findings (HSROC; no summary operating point reported): 'ECM: specificity from 0.73 to 0.96 ... CarieScan Pro: specificity from 0 to 1.00'. Across all 7 studies (8 datasets), covering 719 tooth surfaces or sites (no…
    7 studies
    Very low

Fibre-optic transillumination (FOTI) vs Reference standard (histology, excavation, radiographs/microCT, or tooth separation)

Specificity for detection and diagnosis of early (enamel) caries · Asymptomatic children, adolescents, or adults presenting for clinical examination (in vivo studies), or extracted teeth of children or…
1 finding from 1 review

Electronic caries monitor (ECM) device (ECM II / ECM III / ECM IV) vs Reference standard (histology, excavation, or enhanced visual examination)

Specificity · Children, adolescents, or adults presenting asymptomatically or suspected of early enamel caries (in vivo), or extracted teeth of…
1 finding from 1 review