Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, fibre-optic transillumination pooled specificity was 0.97 (95% CI 0.89 to 0.994) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Specificity 0.97 [0.89, 0.994]
2 studies
GRADE not reported
DOR 37.77 [13.69, 104.19]
2 studies
GRADE not reported
AUC 0.92
2 studies
GRADE not reported
Show 1 more finding
Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, conventional D-speed bitewing radiography had a pooled diagnostic odds ratio of 5.2 (95% CI 1.6, 16.8) for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, visual examination had a pooled sensitivity of 0.64 (95% CI 0.42, 0.81) for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.92 for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, conventional bitewing radiography (D-speed) pooled sensitivity was 0.79 (95% CI 0.41 to 0.96) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Sensitivity 0.79 [0.41, 0.96]
2 studies
GRADE not reported
Specificity 0.75 [0.68, 0.82]
2 studies
GRADE not reported
AUC 0.77
2 studies
GRADE not reported
Show 1 more finding
DOR 11.79 [2.43, 57.24]
2 studies
GRADE not reported
Diagnostic accuracy for proximal caries detection (caries detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)
Under in vivo conditions, sensor-based digital bitewing radiography had a pooled specificity of 0.93 (95% CI 0.77, 0.98) for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for proximal caries detection (1/3 dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, conventional F-speed bitewing radiography had a summary ROC AUC of 0.98 for proximal caries detection at the 1/3 dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, laser fluorescence pen (2190) pooled specificity was 0.77 (95% CI 0.62 to 0.88) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Specificity 0.77 [0.62, 0.88]
4 studies
GRADE not reported
Sensitivity 0.63 [0.37, 0.83]
4 studies
GRADE not reported
DOR 5.85 [1.77, 19.30]
4 studies
GRADE not reported
Show 1 more finding
AUC 0.78
4 studies
GRADE not reported
Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, laser fluorescence (DIAGNOdent 2190) had a summary ROC AUC of 0.91 for proximal caries detection at the caries detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for proximal caries detection (1/3 dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, visual examination had a pooled specificity of 0.84 (95% CI 0.76, 0.89) for proximal caries detection at the 1/3 dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, digital bitewing radiography (phosphor plates) pooled specificity was 0.95 (95% CI 0.59 to 0.995) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Specificity 0.95 [0.59, 0.995]
2 studies
GRADE not reported
AUC 0.73
2 studies
GRADE not reported
Sensitivity 0.48 [0.24, 0.73]
2 studies
GRADE not reported
Show 1 more finding
DOR 15.57 [0.47, 515.27]
2 studies
GRADE not reported
Diagnostic accuracy for occlusal caries detection at the 1/3 dentin caries detection level (Ekstrand; D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, visual examination pooled specificity was 0.77 (95% CI 0.67 to 0.85) for occlusal caries at the 1/3 dentin detection level; ungraded.
4 findings from 1 review
Specificity 0.77 [0.67, 0.85]
3 studies
GRADE not reported
Sensitivity 0.72 [0.52, 0.86]
3 studies
GRADE not reported
DOR 10.18 [3.94, 26.29]
3 studies
GRADE not reported
Show 1 more finding
AUC 0.77
3 studies
GRADE not reported
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, conventional bitewing radiography (E-speed) pooled diagnostic odds ratio was 127.56 (95% CI 7.38 to 2203.70) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
DOR 127.56 [7.38, 2203.70]
2 studies
GRADE not reported
Specificity 0.98 [0.79, 0.998]
2 studies
GRADE not reported
AUC 0.90
2 studies
GRADE not reported
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, conventional bitewing radiography (D-speed) pooled sensitivity was 0.65 (95% CI 0.57 to 0.73) for occlusal caries at the caries detection level; ungraded.
4 findings from 1 review
Sensitivity 0.65 [0.57, 0.73]
1 study
GRADE not reported
Specificity 0.58 [0.42, 0.72]
1 study
GRADE not reported
AUC 0.65
1 study
GRADE not reported
Show 1 more finding
DOR 2.59 [1.24, 5.44]
1 study
GRADE not reported
Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces
In in vivo, conventional bitewing radiography (E-speed) pooled sensitivity was 0.80 (95% CI 0.71 to 0.87) for occlusal caries at the caries detection level; ungraded.
4 findings from 1 review
Sensitivity 0.80 [0.71, 0.87]
1 study
GRADE not reported
DOR 60.37 [3.31, 1100.70]
1 study
GRADE not reported
AUC 0.94
1 study
GRADE not reported
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the 1/3 dentin caries detection level (Ekstrand; D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, visual examination pooled diagnostic odds ratio was 16.6 (95% CI 4.85 to 56.79) for occlusal caries at the 1/3 dentin detection level; ungraded.
4 findings from 1 review
DOR 16.6 [4.85, 56.79]
2 studies
GRADE not reported
Specificity 0.88 [0.83, 0.92]
2 studies
GRADE not reported
Sensitivity 0.69 [0.51, 0.82]
2 studies
GRADE not reported
Show 1 more finding
AUC 0.89
2 studies
GRADE not reported
Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)
Under in vitro conditions, phosphor-plate digital bitewing radiography had a summary ROC AUC of 0.92 for proximal caries detection at the dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, conventional bitewing radiography (F-speed) pooled specificity was 0.97 (95% CI 0.71 to 0.998) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, conventional bitewing radiography (D-speed) pooled specificity was 0.73 (95% CI 0.53 to 0.87) for occlusal caries at the dentin detection level; ungraded.
4 findings from 1 review
Show 1 more finding
Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces
In in vitro, visual examination pooled summary ROC AUC was 0.59 for occlusal caries at the caries detection level; ungraded.
4 findings from 1 review
Show 1 more finding