Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

398 questions · 757 findings · 66 reviews · All outcomes

No studies found 20 · 2.6%GRADE not reported 574 · 75.8%Very low 39 · 5.2%Low 49 · 6.5%Moderate 53 · 7%High 22 · 2.9%

Conventional bitewing radiography, F-speed film vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, conventional F-speed bitewing radiography had a summary ROC AUC of 0.72 for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2190/pen) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, laser fluorescence (DIAGNOdent 2190) had a summary ROC AUC of 0.83 for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, conventional E-speed bitewing radiography had a pooled sensitivity of 0.42 (95% CI 0.28, 0.57) for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.81 for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, conventional E-speed bitewing radiography had a pooled diagnostic odds ratio of 31.40 (95% CI 14.31, 68.93) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, phosphor plate (PSP) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (dentin detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, phosphor-plate digital bitewing radiography had a pooled specificity of 0.60 (95% CI 0.20, 0.90) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2190/pen) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (dentin detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, laser fluorescence (DIAGNOdent 2190) had a pooled specificity of 0.60 (95% CI 0.15, 0.93) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography, F-speed film vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, conventional F-speed bitewing radiography had a pooled diagnostic odds ratio of 8.7 (95% CI 4.2, 18.1) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (D-speed film) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, conventional D-speed bitewing radiography had a pooled specificity of 0.99 (95% CI 0.96, 0.999) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, sensor-based (CCD/CMOS) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, sensor-based digital bitewing radiography had a pooled diagnostic odds ratio of 5.01 (95% CI 2.83, 8.88) for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Visual examination (VE) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, visual examination pooled summary ROC AUC was 0.70 for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, laser fluorescence (DIAGNOdent 2095) pooled summary ROC AUC was 0.79 for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, conventional bitewing radiography (E-speed) pooled sensitivity was 0.48 (95% CI 0.21 to 0.77) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2095) vs Cavity preparation or biopsy (operative validation)

Diagnostic accuracy for occlusal caries detection at the caries detection level (D0 versus D1-D4) · Human permanent posterior teeth (premolars and molars) in patients, occlusal (pit-and-fissure) surfaces

In in vivo, laser fluorescence (DIAGNOdent 2095) pooled diagnostic odds ratio was 18.33 (95% CI 7.57 to 44.37) for occlusal caries at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, sensor-based (CCD/CMOS) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (dentin detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, sensor-based digital bitewing radiography had a pooled diagnostic odds ratio of 12.84 (95% CI 6.56, 25.13) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Visual examination (VE) vs Histological validation (serial sectioning, grinding, hemisection, or microradiography)

Diagnostic accuracy for occlusal caries detection at the dentin caries detection level (D0-2 versus D3-4) · Extracted human permanent posterior teeth (premolars and molars), occlusal (pit-and-fissure) surfaces

In in vitro, visual examination pooled sensitivity was 0.46 (95% CI 0.20 to 0.73) for occlusal caries at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Digital bitewing radiography, phosphor plate (PSP) vs Histological validation of dental tissues (gold standard)

Diagnostic accuracy for proximal caries detection (caries detection level) · Extracted permanent posterior teeth with proximal surfaces (in vitro)

Under in vitro conditions, phosphor-plate digital bitewing radiography had a summary ROC AUC of 0.82 for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Conventional bitewing radiography (E-speed film) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (dentin detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, conventional E-speed bitewing radiography had a pooled specificity of 0.91 (95% CI 0.80, 0.96) for proximal caries detection at the dentin detection level; ungraded.

4 findings from 1 review
Show 1 more finding

Laser fluorescence (DIAGNOdent 2190/pen) vs Direct visual examination after tooth separation or bioptical cavity preparation

Diagnostic accuracy for proximal caries detection (caries detection level) · Patients with permanent posterior teeth, proximal surfaces assessed clinically (in vivo)

Under in vivo conditions, laser fluorescence (DIAGNOdent 2190) had a summary ROC AUC of 0.96 for proximal caries detection at the caries detection level; ungraded.

4 findings from 1 review
Show 1 more finding