Compliance with guidance ‐ Noncompliance with doffing guidance · healthcare worker volunteers
It is very uncertain whether personal protective equipment (PPE) types: powered, air‐purifying… changes compliance: noncompliance with doffing guidance compared with N95 mask plus gown (very low certainty).
1 finding from 1 review
RR 0.5 [0.2, 1.23]
50 participants
Very low
Outcomes at end of treatment · adults with tinnitus
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Impact of tinnitus on quality of life · adults with tinnitus
1 finding from 1 review
Serious adverse effects · adults with tinnitus
CBT showed no clear difference in serious adverse effects compared with TRT (directive counselling and bilateral masking) (low certainty).
1 finding from 1 review
Depression · adults with tinnitus
1 finding from 1 review
Anxiety · adults with tinnitus
1 finding from 1 review
Health‐related quality of life · adults with tinnitus
1 finding from 1 review
Negatively biased interpretations of tinnitus · adults with tinnitus
1 finding from 1 review
Other adverse effects · adults with tinnitus
1 finding from 1 review
Failure with primary modality of resuscitation · neonatal resuscitation
LMA probably leads to lower failure with primary modality of resuscitation compared with BMV (moderate certainty).
1 finding from 1 review
Death or HIE · neonatal resuscitation
LMA showed no clear difference in death or HIE compared with endotracheal intubation (low certainty).
1 finding from 1 review
Need for intubation · neonatal resuscitation
LMA probably leads to lower need for intubation compared with BMV (moderate certainty).
1 finding from 1 review
Apgar score ≤ 7 at 5 minutes · neonatal resuscitation
LMA probably leads to lower apgar score ≤ 7 at 5 minutes compared with BMV (moderate certainty).
1 finding from 1 review
Admission to neonatal intensive care unit · neonatal resuscitation
LMA probably leads to lower admission to NICU compared with BMV (moderate certainty).
1 finding from 1 review
Death or HIE · neonatal resuscitation
LMA showed no clear difference in death or HIE compared with BMV (low certainty).
1 finding from 1 review
Failure to correctly insert the device · neonatal resuscitation
It is very uncertain whether LMA changes failure to correctly insert the device compared with endotracheal intubation (very low certainty).
1 finding from 1 review
Successful insertion of device at first attempt · neonatal resuscitation
It is very uncertain whether LMA changes successful insertion of device at first attempt compared with endotracheal intubation (very low certainty).
1 finding from 1 review
Apgar score ≤ 7 at 5 minutes · neonatal resuscitation
LMA showed no clear difference in apgar score ≤ 7 at 5 minutes compared with endotracheal intubation (low certainty).
1 finding from 1 review
Soft tissue trauma after device inserted · neonatal resuscitation
LMA showed no clear difference in soft tissue trauma after device inserted compared with endotracheal intubation (low certainty).
1 finding from 1 review
Laryngospasm · patients with general anaesthesia
Early removal of the LMA showed no clear difference in laryngospasm (immediate) compared with late removal of the LMA after general anaesthesia (low certainty).
1 finding from 1 review