Marginal bone level change · Patients with compromised teeth to be extracted who require single dental implants in fresh postextraction sockets
Immediate implants (placed just after tooth extraction) showed no clear difference in perimplant marginal bone level changes compared with immediate-delayed implants (placed within 8 weeks after tooth…; GRADE not reported.
1 finding from 1 review
Prosthesis failure · Patients receiving immediate single implants in fresh extraction sockets (maxillary anterior/premolar sites)
Autogenous bone graft augmentation at the immediate implant site led to lower prosthesis failure compared with no augmentation; GRADE not reported.
1 finding from 1 review
In total two implants were lost in the autogenous bone group, whereas no complications or failures occurred in the non-augmented control group; underpowered, no statistically significant difference (Chen 2005b).
1 study · 26 participants
GRADE not reported
Implant failure · Patients receiving immediate single implants in fresh extraction sockets (maxillary anterior/premolar sites)
Autogenous bone graft augmentation at the immediate implant site led to lower implant failure compared with no augmentation; GRADE not reported.
1 finding from 1 review
Major complications at the implant/donor site · Patients receiving immediate single implants in fresh extraction sockets (maxillary anterior/premolar sites)
Autogenous bone graft augmentation at the immediate implant site led to lower major complications at the implant/donor site compared with no augmentation; GRADE not reported.
1 finding from 1 review
Two complications occurred in the group treated with autogenous bone (one abscess that determined the early failure of the implant and one wound dehiscence); none in the control group.
1 study · 26 participants
GRADE not reported
Vertical bone gain · Patients receiving immediate single implants in fresh extraction sockets (maxillary anterior/premolar sites)
Autogenous bone graft augmentation at the immediate implant site showed no clear difference in bone gain (vertical - VDH) compared with no augmentation; GRADE not reported.
1 finding from 1 review
Both treatments resulted in statistically significant bone gain, however no statistically significant differences were found between the two procedures for vertical height of the defect (VDH) (Chen 2005b).
1 study · 26 participants
GRADE not reported
Bone gain (horizontal - HDD) · Patients receiving immediate single implants in fresh extraction sockets (maxillary anterior/premolar sites)
Autogenous bone graft augmentation at the immediate implant site showed no clear difference in bone gain (horizontal - HDD) compared with no augmentation; GRADE not reported.
1 finding from 1 review
Prosthesis failure · Patients who are having osseointegrated root-form dental implants
It is very uncertain whether immediate loading changes prosthesis failure compared with early loading (very low certainty).
1 finding from 1 review
Marginal bone level change · Patients who are having osseointegrated root-form dental implants
Immediate loading showed no clear difference in marginal bone level changes compared with early loading; GRADE not reported.
1 finding from 1 review
MD -0.06 [-0.16, 0.03]
3 studies
GRADE not reported
Marginal bone level change · Patients who are having osseointegrated root-form dental implants
Immediate loading led to lower marginal bone level changes compared with conventional loading; GRADE not reported.
1 finding from 1 review
MD -0.10 [-0.20, -0.01]
9 studies
GRADE not reported
Prosthesis failure · Patients who are having osseointegrated root-form dental implants
It is very uncertain whether immediate loading changes prosthesis failure compared with conventional loading (very low certainty).
1 finding from 1 review
Implant failure · Patients who are having osseointegrated root-form dental implants
Immediate loading showed no clear difference in implant failure compared with conventional loading; GRADE not reported.
1 finding from 1 review
RR 1.50 [0.60, 3.77]
10 studies
GRADE not reported
Implant failure · Patients who are having osseointegrated root-form dental implants
Immediate loading showed no clear difference in implant failure compared with early loading; GRADE not reported.
1 finding from 1 review
RR 0.65 [0.26, 1.64]
5 studies
GRADE not reported
ADHD symptoms · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
1 finding from 1 review
Clinical impression: severity ‐ not reported · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Clinical impression: improvement‐ not reported · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Anxiety · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
1 finding from 1 review
Depression: investigator‐rated · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
1 finding from 1 review
Harms: adverse events (poorly assessed and reported) · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
ADHD symptom severity: patient rated · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
1 finding from 1 review
Clinical impression: severity · adults with ADHD (available evidence for participants aged between 25 to 53 years old)
1 finding from 1 review