Primary study · included by 1 review

Clinical, radiographic and patient-reported outcomes of zirconia and titanium implants in the posterior zone after 1 year of loading-A randomized controlled trial.

Zuercher 2024 · Zuercher Anina N, Balmer Marc, Brügger Lily V, et al. · Clinical oral implants research · 2024

Included by

Prevalence of Peri-Implantitis Around Zirconia Implants: A Systematic Review and Meta-Analysis of Current Evidence.
Non-Cochrane · prognostic · 2026 · cited as Zuercher 2024 · Table 1; ref 10; Results (forest plot follow-up subgroup)
Outcome this study informsPooled effectEvidenceCertainty
Peri-implantitis prevalence (implant level)
Zirconia implants vs None (single-arm prevalence) · Follow-up <= 3 years
Prevalence (%) 2 [0, 6]10 studies · 533 participantsGRADE not reported
Peri-implantitis prevalence (implant level)
Zirconia implants vs None (single-arm prevalence) · Follow-up <= 3 years
Prevalence (%) 1 [0, 5]11 studies · 579 participantsVery low
Peri-implantitis prevalence (implant level)
Zirconia implants vs Titanium implants · 12 to 60 months follow-up
RR 1.13 [0.33, 3.91]6 studies · 313 participantsLow
Peri-implantitis prevalence (implant level)
Zirconia implants vs Titanium implants · 12 to 60 months follow-up
RR 1.66 [0.48, 5.71]5 studies · 211 participantsGRADE not reported

1 including review in total.