Primary study · included by 1 review

Single-piece zirconia versus single-piece titanium, narrow-diameter dental implants in the anterior maxilla: 5-year post-loading results of a randomized clinical trial.

Ruiz Henao 2024 · Ruiz Henao Paula Andrea, Magrin Gabriel Leonardo, Caneiro-Queija Leticia, et al. · Clinical oral implants research · 2024

Included by

Prevalence of Peri-Implantitis Around Zirconia Implants: A Systematic Review and Meta-Analysis of Current Evidence.
Non-Cochrane · prognostic · 2026 · cited as Henao 2024 · Table 1; ref 9; Results (forest plot follow-up subgroup)
Outcome this study informsPooled effectEvidenceCertainty
Peri-implantitis prevalence (implant level)
Zirconia implants vs Titanium implants · 12 to 60 months follow-up
RR 1.13 [0.33, 3.91]6 studies · 313 participantsLow
Peri-implantitis prevalence (implant level)
Zirconia implants vs Titanium implants · 12 to 60 months follow-up
RR 1.66 [0.48, 5.71]5 studies · 211 participantsGRADE not reported
Peri-implantitis prevalence (implant level)
Zirconia implants vs None (single-arm prevalence) · Follow-up > 3 to 5 years
Prevalence (%) 2 [0, 8]5 studies · 149 participantsGRADE not reported
Peri-implantitis prevalence (implant level)
Zirconia implants vs None (single-arm prevalence) · Follow-up > 3 to 5 years
Prevalence (%) 2 [0, 5]6 studies · 221 participantsLow

1 including review in total.