Primary study · included by 1 review
Accuracy of splint vs splintless technique for virtually planned orthognathic surgery: A voxel-based three-dimensional analysis.
Karanxha 2021 · Karanxha Lorena, Rossi Diego, Hamanaka Ryo, et al. · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2021
Included by
| Outcome this study informs | Pooled effect | Evidence | Certainty |
|---|---|---|---|
Angular deviation, pitch (degrees) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.50 [-1.32, 0.31] | 6 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.54 [-0.89, -0.18] | 7 studies | GRADE not reported |
Angular deviation, yaw (degrees) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.63 [-1.11, -0.15] | 6 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.40 [-0.69, -0.11] | 15 studies | GRADE not reported |
Combined three-dimensional linear deviation (mm), supportive summary Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.51 [-0.70, -0.33] | 14 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.50 [-1.77, 0.78] | 4 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.52 [-0.77, -0.28] | 15 studies | Low |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.34 [-0.55, -0.12] | 13 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.41 [-0.69, -0.13] | 7 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.27 [-1.66, 1.13] | 4 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.54 [-1.10, 0.01] | 4 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.54 [-0.86, -0.22] | 7 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.48 [-0.78, -0.17] | 15 studies | Low |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.33 [-0.56, -0.10] | 10 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.35 [-0.93, 0.24] | 8 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.54 [-0.96, -0.13] | 8 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.41 [-0.74, -0.07] | 6 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.40 [-0.60, -0.20] | 13 studies | Low |
Combined three-dimensional angular deviation (degrees) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.54 [-1.07, -0.01] | 6 studies | Very low |
Combined three-dimensional linear deviation (mm), supportive summary Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.46 [-0.66, -0.25] | 9 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.19 [-0.40, 0.02] | 4 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.91 [-1.39, -0.42] | 4 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.64 [-1.06, -0.22] | 4 studies | GRADE not reported |
Angular deviation, roll (degrees) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.72 [-1.15, -0.29] | 6 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.36 [-2.03, 1.31] | 4 studies | GRADE not reported |
Combined three-dimensional linear deviation (mm), supportive summary Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.56 [-0.92, -0.19] | 9 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.36 [-0.61, -0.10] | 7 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.34 [-0.89, 0.22] | 7 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.47 [-1.31, 0.37] | 3 studies | GRADE not reported |
Mediolateral translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.13 [-0.62, 0.37] | 2 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.33 [-0.67, 0.02] | 11 studies | GRADE not reported |
Superoinferior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.28 [-0.62, 0.06] | 15 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.39 [-0.70, -0.08] | 11 studies | GRADE not reported |
Anteroposterior translational deviation (mm) Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative | MD -0.19 [-0.64, 0.25] | 7 studies | GRADE not reported |
1 including review in total.