Primary study · included by 1 review

Computer-Aided Design and Manufacturing Cutting and Drilling Guides with Prebent Titanium Plates Improve Surgical Accuracy of Skeletal Class III Malocclusion.

Li 2020 · Li Kehan, Li Jiayang, Du Wen, et al. · Plastic and reconstructive surgery · 2020

Included by

Outcome this study informsPooled effectEvidenceCertainty
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.54 [-0.89, -0.18]7 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.40 [-0.69, -0.11]15 studiesGRADE not reported
Combined three-dimensional linear deviation (mm), supportive summary
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.51 [-0.70, -0.33]14 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.50 [-1.77, 0.78]4 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.52 [-0.77, -0.28]15 studiesLow
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.27 [-1.66, 1.13]4 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.54 [-1.10, 0.01]4 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.54 [-0.86, -0.22]7 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.48 [-0.78, -0.17]15 studiesLow
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.35 [-0.93, 0.24]8 studiesGRADE not reported
Overall postoperative complications
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Postoperative (follow-up varied)
RR 1.01 [0.64, 1.60]9 studies · 538 participantsLow
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.54 [-0.96, -0.13]8 studiesGRADE not reported
Combined three-dimensional linear deviation (mm), supportive summary
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.46 [-0.66, -0.25]9 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.19 [-0.40, 0.02]4 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.91 [-1.39, -0.42]4 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.36 [-2.03, 1.31]4 studiesGRADE not reported
Operative time (minutes), total bimaxillary operation time
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Intraoperative
MD -10.77 [-47.99, 26.44]4 studiesVery low
Combined three-dimensional linear deviation (mm), supportive summary
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.56 [-0.92, -0.19]9 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.34 [-0.89, 0.22]7 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.33 [-0.67, 0.02]11 studiesGRADE not reported
Superoinferior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.28 [-0.62, 0.06]15 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.39 [-0.70, -0.08]11 studiesGRADE not reported
Anteroposterior translational deviation (mm)
Patient-specific implant (PSI) workflows (cutting/drilling guides and/or customized osteosynthesis plates) vs CAD/CAM occlusal splint or wafer workflows · Within 3 days to 1 month postoperative
MD -0.19 [-0.64, 0.25]7 studiesGRADE not reported

1 including review in total.