Primary study · included by 1 review

Resonance Frequency Analysis of Tapered Implants Placed at Maxillary Posterior Sites After Lateral Sinus Augmentation: A 1.5-year Follow-Up Prospective Study.

Park et al., 2019 · Park Yun-Ho, Jung Ui-Won, Kim Chang-Sung, et al. · Implant dentistry · 2019

Included by

Resonance Frequency Analysis and Clinical Outcomes in Implant Dentistry: A Systematic Review and Meta-Analysis.
Non-Cochrane · prognostic · 2026 · cited as Park et al., 2019 · Table 1; Results Quantitative Analysis (ISQ-IT meta-analysis)
Outcome this study informsPooled effectEvidenceCertainty
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.48362 [-0.070, 0.809]3 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.46 [0.34, 0.57]20 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.454 [0.333, 0.560]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.4760257 [0.201, 0.681]2 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.435 [0.307, 0.547]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.3927642 [0.261, 0.509]16 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.3953134 [0.271, 0.505]9 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.43 [0.32, 0.54]21 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.7551383 [0.614, 0.849]2 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.446 [0.318, 0.557]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.448 [0.322, 0.558]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.433 [0.306, 0.545]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.435 [0.309, 0.550]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.431 [0.302, 0.544]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.403 [0.289, 0.506]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.422 [0.295, 0.534]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.423 [0.297, 0.535]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.450 [0.327, 0.558]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.436 [0.308, 0.549]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.44 [0.32, 0.55]20 studies · 6160 implants participantsVery low
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.432 [0.303, 0.546]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.4441092 [0.222, 0.622]9 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.427 [0.298, 0.540]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.456 [0.338, 0.559]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.437 [0.309, 0.549]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.445 [0.318, 0.555]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.407 [0.290, 0.513]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.5649868 [0.377, 0.708]3 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.436 [0.306, 0.550]19 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.4488072 [0.236, 0.620]9 studiesGRADE not reported
Pearson correlation (r) between ISQ and insertion torque
Implant stability quotient (ISQ, resonance frequency analysis) at implant placement vs Insertion torque (IT) as the correlated measure · ISQ at implant placement (T0)
Pearson r 0.451 [0.329, 0.558]19 studiesGRADE not reported

1 including review in total.