Primary study · included by 1 review

The effect of magnesium-incorporated hydroxyapatite coating on titanium implant fixation in ovariectomized rats.

Li 2014 · Li Xudong, Li Yunfeng, Liao Yunmao, et al. · The International journal of oral & maxillofacial implants · 2014

Included by

Outcome this study informsPooled effectEvidenceCertainty
Bone-to-implant contact (BIC, %)
Ti implants coated with or incorporating magnesium (Mg) vs Ti implants without Mg (same base surface, uncoated or non-Mg coated) · Healing periods 2 to 24 weeks, pooled across timepoints
MD 13.20 [7.29, 19.11]10 studies · 246 participantsGRADE not reported
Bone area (BA, %)
Ti implants coated with or incorporating magnesium (Mg) vs Ti implants without Mg (same base surface, uncoated or non-Mg coated) · Healing periods 2 to 24 weeks, pooled across timepoints
MD 2.51 [-2.80, 7.81]8 studies · 230 participantsGRADE not reported