Primary study · included by 1 review
Extracellular microRNA-223-5p Levels in Plasma, Saliva, and Gingival Crevicular Fluid in Periodontal Disease as a Potential Diagnostic Marker − A Case–Control Analysis
Bandi 2023a · Bandi Dhathri Priya, Sudhakar Uma, Parthasarathy Harinath, et al. · Journal of Orofacial Sciences · 2023
Included by
| Outcome this study informs | Pooled effect | Evidence | Certainty |
|---|---|---|---|
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.676 | 5 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.70 | 6 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.70 [0.55, 0.84] | 6 studies | Low |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.72 | 3 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.68 | 3 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.716 | 5 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.659 | 5 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.750 | 5 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.698 | 5 studies | GRADE not reported |
Pooled sensitivity miR-223 expression level as index test (qPCR) vs Reference standard: clinical or radiographic periodontitis criteria (CAL, PPD, radiographic bone loss) | Sensitivity 0.691 | 5 studies | GRADE not reported |
1 including review in total.