Non-Cochrane · intervention · PM42368773

Accuracy and Functional Performance of Artificial Intelligence-Based Automated Crown Design Systems: A Systematic Review and Meta-Analysis.

Holiel Ahmed A, Al Nakouzi Mounir M, Enrique Cuevas-Suárez Carlos, et al. · Biomedical engineering and computational biology · 2026 · PubMed · doi:10.1177/11795972261463709

Findings

Population Digital datasets of teeth requiring crown restoration (clinical cases, typodont models, digital casts)

19 findings

AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Occlusal contact points
GAN based
SMD -0.87 [-1.13, -0.60]
GRADE not reported
2 studies · 1250 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Overall accuracy (RMS deviation)SMD -0.15 [-1.04, 0.74]
GRADE not reported
6 studies · 424 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Internal fitSMD -0.15 [-0.47, 0.17]
GRADE not reported
2 studies · 180 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Cusp angle reproductionSMD -0.24 [-0.88, 0.40]
GRADE not reported
5 studies · 362 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Occlusal contact pointsSMD -0.43 [-0.95, 0.10]
GRADE not reported
4 studies · 1490 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Marginal gapSMD 0.44 [0.17, 0.71]
GRADE not reported
2 studies · 280 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Overall accuracy (RMS deviation)
Knowledge-based
SMD 0.69 [-0.14, 1.52]
GRADE not reported
1 study · 24 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Chamfer distanceSMD -1.00 [-1.20, -0.80]
GRADE not reported
2 studies · 460 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Profile discrepancy
GAN based
SMD 0.13 [-0.04, 0.29]
GRADE not reported
2 studies · 546 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Occlusal morphologySMD -0.70 [-0.90, -0.51]
GRADE not reported
2 studies · 460 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Occlusal contact points
Transformer-based model
SMD 0.57 [-1.81, 2.96]
GRADE not reported
2 studies · 240 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Cusp angle reproduction
GAN based
SMD -0.81 [-1.80, 0.19]
GRADE not reported
3 studies · 242 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Profile discrepancy
Transformer-based model
SMD 0.89 [-1.22, 3.01]
GRADE not reported
3 studies · 208 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Overall accuracy (RMS deviation)
Transformer-based model
SMD -0.79 [-1.63, 0.04]
GRADE not reported
2 studies · 156 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Design timeSMD -1.44 [-1.91, -0.97]
GRADE not reported
2 studies · 140 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Cusp angle reproduction
Transformer-based model
SMD 0.30 [-0.66, 1.27]
GRADE not reported
1 study · 96 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Profile discrepancySMD 0.46 [-0.14, 1.05]
GRADE not reported
5 studies · 754 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Overall accuracy (RMS deviation)
GAN based
SMD -0.19 [-1.49, 1.10]
GRADE not reported
3 studies · 244 participants
AI-based automated crown design systems (ML, DL, GAN, transformer or knowledge-based)Conventional crown design workflows (technician-driven or manual CAD, library-based CAD/CAM)Cusp angle reproduction
Knowledge-based
SMD 0.68 [-0.15, 1.50]
GRADE not reported
1 study · 24 participants

Included primary studies 17

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Chen 2022
Morphology and fracture behavior of lithium disilicate dental crowns designed by human and knowledge-based AI.
PMID:35508087
20221 other reviewnot statednot extracted yet
Cho 2024
Tooth morphology, internal fit, occlusion and proximal contacts of dental crowns designed by deep learning-based dental software: A…
PMID:38163455
20241 other reviewnot statednot extracted yet
Ding 2023
Morphology and mechanical performance of dental crown designed by 3D-DCGAN.
PMID:36822895
20231 other reviewnot statednot extracted yet
Liu 2025
Evaluation of the accuracy, occlusal contact and clinical applications of zirconia crowns using artificial intelligence design versus…
PMID:40654460
20251 other reviewnot statednot extracted yet
Nagata 2025
Verification of the accuracy and design time of crowns designed with artificial intelligence.
PMID:40061025
20251 other reviewnot statednot extracted yet
Wu 2024
Comparison of the Efficacy of Artificial Intelligence-Powered Software in Crown Design: An In Vitro Study.
PMID:39069456
20251 other reviewnot statednot extracted yet
Aktas 2024
Effects of design software program and manufacturing method on the marginal and internal adaptation of esthetic crowns for primary teeth:…
PMID:38195256
2024this review onlynot statednot extracted yet
Broll 2025
Influence of digital crown design software on morphology, occlusal characteristics, fracture force and marginal fit.
PMID:40947383
2026this review onlynot statednot extracted yet
Cakmak 2024
Can deep learning-designed anterior tooth-borne crown fulfill morphologic, aesthetic, and functional criteria in clinical practice?
PMID:39326724
2024this review onlynot statednot extracted yet
Chau 2024
Accuracy of artificial intelligence-designed single-molar dental prostheses: A feasibility study.
PMID:36631366
2024this review onlynot statednot extracted yet
Cho 2023
Time efficiency, occlusal morphology, and internal fit of anatomic contour crowns designed by dental software powered by generative…
PMID:37804938
2023this review onlynot statednot extracted yet
Cho 2025
A comparison between commercially available artificial intelligence-based and conventional human expert-based digital workflows for…
PMID:40628576
2026this review onlynot statednot extracted yet
Hlaing 2025
Artificial Intelligence-Driven Automated Design of Anterior and Posterior Crowns Under Diverse Occlusal Scenarios.
PMID:40910757
2026this review onlynot statednot extracted yet
Sawangsri 2025
Acceptability and deviation of finish line detection and restoration contour design in single-unit crown: Comparative evaluation between 2…
PMID:40234164
2025this review onlynot statednot extracted yet
Wang 2025
Comparative analysis of full crown morphology designed by artificial intelligence and dental technicians.
PMID:40998103
2025this review onlynot statednot extracted yet
Win 2025
Fit accuracy of complete crowns fabricated by generative artificial intelligence design: a comparative clinical study.
PMID:40919046
2025this review onlynot statednot extracted yet
Zhao 2026
Tooth generative adversarial network: Anatomical optimisation using Wasserstein generative adversarial network for tooth generation…
DOI:10.1016/j.engappai.2026.114215
2026this review onlynot statednot extracted yet

Overlap with other reviews

Reviews that include the same primary studies are not independent evidence. Shared counts match studies by PMID, DOI or NCT, and otherwise by author and year (a probable match). Only the non-Cochrane dental reviews have study lists, so overlap with Cochrane reviews is not counted yet.

Review question

ElementPlanned (methods)Found (results)
PopulationDigital datasets of teeth requiring crown restoration (clinical cases, typodont models, digital casts; anterior and posterior)Digital tooth datasets and crowns (in vitro models, digital casts, intraoral scans; 17 studies)
InterventionAI-based automated crown design systems (ML, DL, GAN, diffusion, hybrid or knowledge-based)GAN-based, knowledge-based and transformer-labeled AI crown design systems
ComparisonConventional crown design (technician-driven, manual CAD, library-based CAD/CAM, virtual articulator)Conventional CAD or technician-designed crowns
OutcomesRMS deviation, occlusal contact accuracy, cusp morphology, internal fit; marginal adaptation, design time, functional occlusal performanceRMS deviation, cusp angle, occlusal contact points, profile discrepancy, internal fit, chamfer distance, marginal gap, design time, occlusal morphology (13 studies pooled)
Study designsIn vitro, in silico and clinical investigationsMostly in vitro; one in vivo comparative clinical study
TimingNot specifiedNot specified

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalNoPartial Yesno
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalNRSI: Partial Yes · RCT: N/ARCT: N/A · NRSI: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalNRSI: No · RCT: N/ARCT: N/A · NRSI: Nono
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes