Non-Cochrane · intervention · PM42359372

Comparative evaluation of marginal and internal fit of multi-unit fixed dental prostheses: A systematic review and meta-analysis of conventional versus digital impressions.

Sinha Anamika, Srivastava Gunjan, Panda Sangram Kumar, et al. · Dental research journal · 2026 · PubMed · doi:10.4103/drj.drj_604_25

Findings

13 findings

Population
Tooth-supported multi-unit fixed dental prostheses fabricated in vitro (laboratory specimens)Digital impression (intraoral scanner)Conventional impressionInternal fit (internal discrepancy)
Not applicable (in vitro measurement) · In vitro (laboratory) · Total of the intraoral scanner subgroup analysis (Trios, Cerec, iTero)
SMD -0.50 [-0.81, -0.19]
GRADE not reported
8 studies
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions (intraoral scanners)Conventional impressionsInternal fit (internal gap, micrometers)
In vitro (laboratory)
SMD -0.52 [-0.79, -0.24]
GRADE not reported
9 studies · 224 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions (intraoral scanners)Conventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory)
SMD -0.81 [-1.06, -0.56]
GRADE not reported
11 studies · 304 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions (intraoral scanners)Conventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory) · Total of intraoral scanner subgroup analysis
SMD -0.78 [-1.05, -0.52]
GRADE not reported
11 studies · 284 participants
Patients requiring tooth-supported multi-unit fixed dental prosthesesDigital impressions (intraoral scanners)Conventional impressionsMarginal fit (marginal gap, micrometers)
Clinical (RCTs)
SMD -0.25 [-0.64, 0.14]
GRADE not reported
3 studies · 100 participants
Patients requiring tooth-supported multi-unit fixed dental prosthesesDigital impressions (intraoral scanners)Conventional impressionsInternal fit (internal gap, micrometers)
Clinical (RCTs)
SMD -0.15 [-0.55, 0.24]
GRADE not reported
3 studies · 100 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with Trios scannerConventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory) · Trios
SMD -0.91 [-1.30, -0.52]
GRADE not reported
6 studies · 116 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with Trios scannerConventional impressionsInternal fit (internal gap, micrometers)
In vitro (laboratory) · Trios
SMD -0.36 [-0.78, 0.05]
GRADE not reported
5 studies · 96 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with iTero scannerConventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory) · iTero
SMD -0.59 [-1.13, -0.04]
GRADE not reported
3 studies · 64 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with iTero scannerConventional impressionsInternal fit (internal gap, micrometers)
In vitro (laboratory) · iTero
SMD -0.80 [-1.46, -0.13]
GRADE not reported
2 studies · 44 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with Lava scannerConventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory) · Lava
SMD -0.55 [-1.33, 0.22]
GRADE not reported
2 studies · 44 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with Cerec scannerConventional impressionsMarginal fit (marginal gap, micrometers)
In vitro (laboratory) · Cerec
SMD -0.86 [-1.43, -0.30]
GRADE not reported
3 studies · 60 participants
Tooth-supported multi-unit fixed dental prostheses on in vitro modelsDigital impressions with Cerec scannerConventional impressionsInternal fit (internal gap, micrometers)
In vitro (laboratory) · Cerec
SMD -0.54 [-1.17, 0.09]
GRADE not reported
2 studies · 40 participants

Included primary studies 14

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Ahrberg 2016
Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a…
PMID:26070435
20161 other reviewnot statednot extracted yet
Bandiaky 2023
Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions:…
PMID:36627825
20231 other reviewnot statednot extracted yet
Almeida e Silva 2014
Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.
PMID:23716064
2014this review onlynot statednot extracted yet
Arezoobakhsh 2020
Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital…
PMID:30982618
2020this review onlynot statednot extracted yet
Benic 2019
Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures.…
PMID:30396708
2019this review onlynot statednot extracted yet
Keul 2014
Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study.
PMID:24522150
2014this review onlynot statednot extracted yet
Kim 2018
Effect of number of pontics and impression technique on the accuracy of four-unit monolithic zirconia fixed dental prostheses.
PMID:29526302
2018this review onlynot statednot extracted yet
Kocaağaoğlu 2019
Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.
PMID:31754416
2019this review onlynot statednot extracted yet
Morsy 2021
Fit of monolithic multilayer zirconia fixed partial dentures fabricated by conventional versus digital impression: a clinical and…
PMID:33619632
2021this review onlynot statednot extracted yet
Moustapha 2019
Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques.
PMID:31001919
2019this review onlynot statednot extracted yet
Shembesh 2017
An In Vitro Comparison of the Marginal Adaptation Accuracy of CAD/CAM Restorations Using Different Impression Systems.
PMID:26855068
2017this review onlynot statednot extracted yet
Su 2016
Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression.
PMID:27061628
2016this review onlynot statednot extracted yet
Svanborg 2014
Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.
PMID:24723954
2014this review onlynot statednot extracted yet
Uluc 2022
Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and…
PMID:35028021
2022this review onlynot statednot extracted yet

Overlap with other reviews

Reviews that include the same primary studies are not independent evidence. Shared counts match studies by PMID, DOI or NCT, and otherwise by author and year (a probable match). Only the non-Cochrane dental reviews have study lists, so overlap with Cochrane reviews is not counted yet.

Review question

ElementPlanned (methods)Found (results)
PopulationPatients requiring multi-unit fixed dental prostheses (in vivo and in vitro studies)Tooth-supported multi-unit FDPs: 11 in vitro studies and 3 RCTs (8 to 12 patients or specimens per study)
InterventionDigital impressions (intraoral scanners)Digital impressions: Trios, Cerec, iTero, Lava, CS3600, CS3500
ComparisonConventional impressionsConventional impressions (PVS or polyether)
OutcomesMarginal and internal fit (primary); accuracy of different intraoral scanners (secondary)Marginal fit (11 in vitro studies, 3 RCTs); internal fit (9 in vitro studies, 3 RCTs)
Study designsControlled in vivo and in vitro studies published in English, 2013 to January 202511 in vitro studies and 3 RCTs (n=14)
TimingNot specifiedNot specified

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalNoNoyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateNoNoyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesYesno
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: N/ANRSI: Partial Yes · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: No · NRSI: N/ANRSI: No · RCT: Yesno
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalYesYesyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes