Non-Cochrane · intervention · PM42222473

Herbst and Twin Block appliances in Class II malocclusion management for children: a systematic review and meta-analysis.

Coronel-Zubiate Franz Tito, Meza-Málaga Joan Manuel, Luján-Valencia Sara Antonieta, et al. · Frontiers in dental medicine · 2026 · PubMed · doi:10.3389/fdmed.2026.1717387

Findings

Population Growing patients (<=16 years) with Class II malocclusion

33 findings

Herbst applianceTwin Block appliancesi-B (supramentale inferius to point B)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.36 [-0.80, 1.53]
Very low
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-prn
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.00 [-0.51, 0.52]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-pog
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK) · Sensitivity analysis: fixed-effects model
SMD -0.54 [-1.07, -0.02]
GRADE not reported
2 studies · 59 participants
Herbst applianceTwin Block applianceUpper lip thickness
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.27 [-1.20, 0.66]
Very low
Downgraded: imprecision, inconsistency
2 studies · 59 participants
Herbst applianceTwin Block applianceE-line to labrale inferius (E-li)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.29 [-0.42, 0.99]
Low
Downgraded: imprecision, inconsistency
2 studies · 59 participants
Herbst applianceTwin Block applianceSoft tissue convexity (na-prn-pog)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK) · Sensitivity analysis: fixed-effects model
SMD -0.44 [-0.84, -0.03]
GRADE not reported
3 studies · 99 participants
Herbst applianceTwin Block applianceVRL-si
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.48 [-1.16, 0.20]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceMaxillary base (point A/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.01 [-0.23, 0.25]
Moderate
Downgraded: imprecision
2 studies · 263 participants
Herbst applianceTwin Block applianceVRL-ss
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.23 [-0.74, 0.28]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceMandibular base (pg/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.02 [-0.26, 0.22]
Moderate
Downgraded: imprecision
2 studies · 263 participants
Herbst applianceTwin Block applianceSkeletal discrepancy (A point to OLp, Pg to OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.04 [-0.20, 0.28]
Moderate
Downgraded: imprecision
2 studies · 263 participants
Herbst applianceTwin Block appliancePog-pog (soft tissue to hard tissue pogonion)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.34 [-0.86, 0.17]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceComposite mandibular length (pg/OLp + co/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.07 [-0.47, 0.33]
Low
Downgraded: imprecision, inconsistency
2 studies · 263 participants
Herbst applianceTwin Block applianceCondylar head position (co/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.01 [-0.54, 0.51]
Very low
Downgraded: imprecision, inconsistency
2 studies · 263 participants
Herbst applianceTwin Block applianceVRL-si
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK) · Sensitivity analysis: fixed-effects model
SMD -0.52 [-1.04, 0.00]
GRADE not reported
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-pog
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.50 [-1.19, 0.19]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceE-line to labrale superius (E-ls)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.34 [-0.17, 0.86]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-li
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.30 [-0.82, 0.22]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceSoft tissue convexity (na-prn-pog)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.41 [-0.91, 0.09]
Moderate
Downgraded: imprecision
3 studies · 99 participants
Herbst applianceTwin Block applianceLip strain (lip tension)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.18 [-0.33, 0.69]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceConvexity without nose (na-sn-pog)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.53 [-1.20, 0.13]
Low
Downgraded: imprecision, inconsistency
3 studies · 99 participants
Herbst applianceTwin Block applianceNasolabial angle (c-sn-ls)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.01 [-0.38, 0.41]
Moderate
Downgraded: imprecision
3 studies · 99 participants
Herbst applianceTwin Block applianceInterlabial gap
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.12 [-1.37, 1.60]
Very low
Downgraded: imprecision, inconsistency
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-sn
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.10 [-0.61, 0.41]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceBasic upper lip thickness
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.11 [-0.41, 0.62]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceLower lip length (lls-me)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.13 [-0.64, 0.38]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceMentolabial angle (li-sl-pog)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.56 [0.15, 0.96]
Moderate
Downgraded: imprecision, indirectness
3 studies · 99 participants
Herbst applianceTwin Block applianceMolar relationship (ms/OLp-mi/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.19 [-0.55, 0.18]
Low
Downgraded: imprecision, inconsistency
2 studies · 263 participants
Herbst applianceTwin Block applianceMolar relationship (is/OLp-li/OLp)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.31 [-0.56, -0.05]
Moderate
Downgraded: imprecision, indirectness
2 studies · 263 participants
Herbst applianceTwin Block applianceLower lip thickness
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.05 [-0.56, 0.46]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceVRL-ls
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD -0.23 [-0.74, 0.28]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceUpper lip length (sn-uls)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.21 [-0.44, 0.86]
Moderate
Downgraded: imprecision
2 studies · 59 participants
Herbst applianceTwin Block applianceH angle (Holdaway)
Post-treatment (final values, T1) · Orthodontic clinics (Turkey, Brazil, UK)
SMD 0.15 [-0.25, 0.55]
Moderate
Downgraded: imprecision
3 studies · 99 participants

Included primary studies 14

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Baysal 2013
Soft tissue effects of Twin Block and Herbst appliances in patients with Class II division 1 mandibular retrognathy
DOI:10.1093/ejo/cjq187
2011this review onlynot statednot extracted yet
Baysal 2013
Soft tissue effects of Twin Block and Herbst appliances in patients with Class II division 1 mandibular retrognathy.
PMID:21357655
2013this review onlynot statednot extracted yet
Baysal 2014
Dentoskeletal effects of Twin Block and Herbst appliances in patients with Class II division 1 mandibular retrognathy
DOI:10.1093/ejo/cjt013
2013this review onlynot statednot extracted yet
Baysal 2014
Dentoskeletal effects of Twin Block and Herbst appliances in patients with Class II division 1 mandibular retrognathy.
PMID:24663007
2014this review onlynot statednot extracted yet
Brandao 2024
Facial soft tissue changes in adolescent patients treated with three different functional appliances: a randomized clinical trial
DOI:10.1590/2177-6709.29.5.e242440.oar
2024this review onlynot statednot extracted yet
Brandao 2024
Facial soft tissue changes in adolescent patients treated with three different functional appliances: a randomized clinical trial.
PMID:39383371
2024this review onlynot statednot extracted yet
Guler 2020
Comparison of facial soft tissue changes after treatment with 3 different functional appliances
DOI:10.1016/j.ajodo.2019.06.020
2020this review onlynot statednot extracted yet
Guler 2020
Comparison of facial soft tissue changes after treatment with 3 different functional appliances.
PMID:32988567
2020this review onlynot statednot extracted yet
O'Brien 2003
Effectiveness of treatment for Class II malocclusion with the Herbst or twin-block appliances: a randomized, controlled trial.
PMID:12923506
2003this review onlynot statednot extracted yet
OBrien 2003
Effectiveness of treatment for class II malocclusion with the herbst or twin-block appliances: a randomized, controlled trial
DOI:10.1016/s0889-5406(03)00345-7
2003this review onlynot statednot extracted yet
Pacha 2023
The use of the Hanks Herbst vs Twin-block in Class II malocclusion: A randomized controlled trial
DOI:10.1016/j.ajodo.2023.06.002
2023this review onlynot statednot extracted yet
Pacha 2023
The use of the Hanks Herbst vs Twin-block in Class II malocclusion: A randomized controlled trial.
PMID:37409988
2023this review onlynot statednot extracted yet
Pacha 2024
The skeletal and dental effects of Hanks Herbst versus twin block appliances for class II correction in growing patients: a randomized…
DOI:10.1093/ejo/cjad065
2023this review onlynot statednot extracted yet
Pacha 2024
The skeletal and dental effects of Hanks Herbst versus twin block appliances for class II correction in growing patients: a randomized…
PMID:37930325
2024this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationGrowing patients (16 years or younger) with Class II malocclusion treated with functional appliancesGrowing patients with Class II malocclusion, mean age about 11.8 to 13.1 years (n=548 in 7 RCTs; n=99 to 263 per meta-analysis)
InterventionHerbst applianceHerbst appliance (including Hanks Herbst, dental and skeletal anchorage)
ComparisonTwin Block applianceTwin Block appliance
OutcomesSkeletal (SNA, SNB, ANB, Co-Gn, base positions), dental (molar relationship, overjet, overbite) and soft tissue profile changes; primary: molar relationship and mandibular advancement30 skeletal, dental and soft tissue cephalometric outcomes pooled as SMDs
Study designsRCTsRCTs (7 included; 5 in meta-analysis)
TimingBaseline and post-treatmentEnd of treatment, 3 to 16.2 months

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedYesNono
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalYesYesyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: N/ANRSI: N/A · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: Yes · NRSI: N/ANRSI: N/A · RCT: Yesno
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallLowLowyes