Non-Cochrane · intervention · PM41788127

Effect of Direct Versus Indirect Bonding Techniques on Fixed Retainer Failure Rates: A Systematic Review and Meta-Analysis.

Marei Mohamed A, Failakawi Lujain E, Alhouti Fatemah Y, et al. · Cureus · 2026 · PubMed · doi:10.7759/cureus.102821

Findings

Population Patients who completed orthodontic treatment and received a bonded fixed retainer

3 findings

Indirect bonding of fixed retainer (laboratory based, including CAD/CAM)Direct (chairside) bonding of fixed retainerFailure of maxillary fixed retainer
Follow-up 6 to 60 months · Orthodontic retention clinics · Maxillary arch
HR 1.30 [0.89, 1.90]
GRADE not reported
4 studies
Indirect bonding of fixed retainer (laboratory based, including CAD/CAM)Direct (chairside) bonding of fixed retainerFailure of mandibular fixed retainer
Follow-up 6 to 60 months · Orthodontic retention clinics · Mandibular arch
HR 1.41 [1.12, 1.79]
GRADE not reported
15 studies · 1481 participants
Indirect bonding of fixed retainer (laboratory based, including CAD/CAM)Direct (chairside) bonding of fixed retainerFailure of maxillary fixed retainer
Follow-up 6 to 60 months · Orthodontic retention clinics · Maxillary arch (value as stated in Abstract; differs from Figure 3)
HR 1.30 [0.89, 1.90]
GRADE not reported
4 studies

Included primary studies 15

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Gelin 2020
Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled…
PMID:33144526
20201 other reviewFailure of mandibular fixed retainernot extracted yet
Bovali 2014
Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: A single-center randomized controlled trial comparing…
DOI:10.1016/j.ajodo.2014.08.015
2014this review onlyFailure of mandibular fixed retainernot extracted yet
Cokakoglu 2023
Comparison of periodontal status and failure rates with different retainer bonding methods and adhesives: a randomized clinical trial
DOI:10.2319/031622-224.1
2023this review onlyFailure of mandibular fixed retainernot extracted yet
Cornelis 2022
Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment…
DOI:10.1016/j.ajodo.2022.03.014
2022this review onlyFailure of mandibular fixed retainernot extracted yet
Egli 2017
Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment…
DOI:10.1016/j.ajodo.2016.09.009
2017this review onlyFailure of mandibular fixed retainernot extracted yet
Gera 2023
Stability, survival, and patient satisfaction with CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a…
DOI:10.1093/ejo/cjac042
2022this review onlyFailure of mandibular fixed retainer; Failure of maxillary fixed retainernot extracted yet
Gunay 2018
Clinical effectiveness of 2 orthodontic retainer wires on mandibular arch retention
DOI:10.1016/j.ajodo.2017.06.019
2018this review onlyFailure of mandibular fixed retainernot extracted yet
Johal 2025
A comparison of survival rates using 3 methods of mandibular fixed retainer fabrication: A randomized clinical trial
DOI:10.1016/j.ajodo.2025.08.005
2025this review onlyFailure of mandibular fixed retainernot extracted yet
Jowett 2023
CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial
DOI:10.1177/14653125221118935
2022this review onlyFailure of mandibular fixed retainer; Failure of maxillary fixed retainernot extracted yet
Kartal 2021
Comparative evaluation of periodontal effects and survival rates of Memotain and five-stranded bonded retainers
DOI:10.1007/s00056-020-00243-5
2020this review onlyFailure of mandibular fixed retainernot extracted yet
Murugaiyan 2024
Post-treatment stability, survival time and periodontal health associated with vacuum-formed, bonded and rapid prototype retainers: A…
DOI:10.1177/14653125241255702
2024this review onlyFailure of mandibular fixed retainer; Failure of maxillary fixed retainernot extracted yet
Pullisaar 2024
Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers in…
DOI:10.1093/ejo/cjae006
2024this review onlyFailure of mandibular fixed retainer; Failure of maxillary fixed retainernot extracted yet
Shim 2022
Comparative assessment of relapse and failure between CAD/CAM stainless steel and standard stainless steel fixed retainers in orthodontic…
DOI:10.2319/121720-1015.1
2022this review onlyFailure of mandibular fixed retainernot extracted yet
Taner 2011
A prospective clinical evaluation of mandibular lingual retainer survival
DOI:10.1093/ejo/cjr038
2011this review onlyFailure of mandibular fixed retainernot extracted yet
Tran 2024
Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial
DOI:10.1093/ejo/cjad079
2024this review onlyFailure of mandibular fixed retainernot extracted yet

Overlap with other reviews

Reviews that include the same primary studies are not independent evidence. Shared counts match studies by PMID, DOI or NCT, and otherwise by author and year (a probable match). Only the non-Cochrane dental reviews have study lists, so overlap with Cochrane reviews is not counted yet.

Review question

ElementPlanned (methods)Found (results)
PopulationPatients who completed orthodontic treatment and received a fixed retainerOrthodontic retention patients with fixed retainers (n=1481)
InterventionIndirect bonding technique (including CAD/CAM)Indirect bonding (laboratory-based or CAD/CAM) (n=15 studies)
ComparisonDirect bonding techniqueDirect chairside bonding
OutcomesFailure rate of the fixed retainerRetainer failure, mandibular arch (15 studies) and maxillary arch (4 studies); hazard ratio
Study designsRCTs and prospective or retrospective cohort studies13 RCTs and 2 prospective cohort studies
TimingNot specified6 to 60 months follow-up

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: Partial YesNRSI: Partial Yes · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalNRSI: No · RCT: YesRCT: Yes · NRSI: Nono
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowCritically Lowyes