Non-Cochrane · intervention · PM40616206

Is Additive Manufacturing of Dental Zirconia Comparable to Subtractive Methods When Considering Printing Orientation and Layer Thickness? A Systematic Review and Meta-Analysis.

Ruggiero Mirelle M, Souza Letícia V S, Magno Marcela B, et al. · Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026 · PubMed · doi:10.1111/jerd.13514

Findings

19 findings

Population
Monolithic dental zirconia (3Y-TZP) specimensAM (SLA or DLP) zirconia, any printing direction and layer thicknessSubtractive manufacturing (SM; CIP/presintered, milled) zirconiaSurface roughness
Not applicable (laboratory specimens) · Laboratory (in vitro) · Analysis 1: printing direction coded 0 degree, 90 degree and not reported (Abualsaud 90 degree)
MD -0.02 [-0.13, 0.08]
GRADE not reported
5 studies · 68 participants
Monolithic dental zirconia (3Y-TZP) specimensAM (SLA or DLP) zirconia, any printing direction and layer thicknessSubtractive manufacturing (SM; CIP/presintered, milled) zirconiaDensity
Not applicable (laboratory specimens) · Laboratory (in vitro) · Analysis 1: printing direction coded 0 degree, 90 degree and not reported (Abualsaud 90 degree)
MD -0.02 [-0.02, -0.01]
GRADE not reported
7 studies · 100 participants
Monolithic dental zirconia (3Y-TZP) specimensAM (SLA or DLP) zirconia, any printing direction and layer thicknessSubtractive manufacturing (SM; CIP/presintered, milled) zirconiaDensity
Not applicable (laboratory specimens) · Laboratory (in vitro) · Analysis 2: printing direction coded 0 degree and not reported
MD -0.02 [-0.02, -0.01]
GRADE not reported
7 studies · 100 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing (SLA or DLP) zirconia, all printing directions and layer thicknessesSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · Overall
MD -232.25 [-255.64, -208.86]
GRADE not reported
12 studies · 494 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing (SLA or DLP) zirconia, all printing directions and layer thicknessesSubtractive manufacturing (CIP/presintering/milling) zirconiaSurface roughness
Laboratory (in vitro) · Overall analysis 2 (Abualsaud et al. entered at 0 degrees)
MD -0.03 [-0.13, 0.07]
GRADE not reported
5 studies · 68 participants
Monolithic dental zirconia (3Y-TZP) specimensAM (SLA or DLP) zirconia, any printing direction and layer thicknessSubtractive manufacturing (SM; CIP/presintered, milled) zirconiaUniaxial flexural strength (UFS)
Not applicable (laboratory specimens) · Laboratory (in vitro) · Uniaxial flexural strength assessment
MD -84.54 [-347.79, 178.72]
GRADE not reported
8 studies · 250 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 90 degreesSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · Printing direction 90 degrees
MD -266.54 [-470.64, -62.43]
GRADE not reported
7 studies · 239 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 0 degreesSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · Printing direction 0 degrees
MD -120.5 [-243.3, 2.3]
GRADE not reported
10 studies · 378 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia by DLPSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · DLP technology
MD -133.3 [-240.87, -25.73]
GRADE not reported
11 studies · 465 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia by SLASubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · SLA technology
MD -204.72 [-437.45, 28.0]
GRADE not reported
8 studies · 202 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia assessed by biaxial flexural strength (BFS)Subtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · BFS subgroup
MD -156.83 [-243.79, -69.87]
GRADE not reported
6 studies · 244 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 0 degrees, UFSSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 0 degrees and UFS
MD -85.02 [-392.83, 222.8]
GRADE not reported
5 studies · 162 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 0 degrees, BFSSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 0 degrees and BFS
MD -146.92 [-269.2, -24.64]
GRADE not reported
6 studies · 216 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 90 degrees, UFSSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 90 degrees and UFS
MD -207.99 [-366.04, -49.93]
GRADE not reported
4 studies · 112 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia printed at 90 degrees, BFSSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 90 degrees and BFS
MD -339.07 [-826.7, 148.56]
GRADE not reported
3 studies · 127 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia with 25 um layer thicknessSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 25 um layer thickness
MD -111.86 [-206.88, -16.84]
GRADE not reported
4 studies · 258 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia with 50 um layer thicknessSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 50 um layer thickness
MD -158.65 [-235.06, -82.24]
GRADE not reported
2 studies · 70 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia with 25 um layer thickness printed at 0 degreesSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 25 um layer thickness and 0 degrees
MD -215.46 [-376.05, -54.87]
GRADE not reported
4 studies · 192 participants
Monolithic dental zirconia specimens (3Y-TZP)Additive manufacturing zirconia with 25 um layer thickness printed at 90 degreesSubtractive manufacturing (CIP/presintering/milling) zirconiaFlexural strength
Laboratory (in vitro) · 25 um layer thickness and 90 degrees
MD -260.49 [-492.36, -28.62]
GRADE not reported
6 studies · 209 participants

Included primary studies 31

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Abualsaud 2022
Physiomechanical and Surface Characteristics of 3D-Printed Zirconia: An In Vitro Study
DOI:10.3390/ma15196988
2022this review onlynot statednot extracted yet
Alshamrani 2024
Flexural properties and finite element analysis of novel <scp>3D</scp>‐printed ceramic materials via <scp>3D</scp>‐<scp>LCM</scp> technology
DOI:10.1111/adj.13048
2024this review onlynot statednot extracted yet
Bergler 2022
Ceramic Printing— Comparative Study of the Flexural Strength of 3D-Printed and Milled Zirconia
DOI:10.11607/ijp.6749
2022this review onlynot statednot extracted yet
Cameron 2024
Assessment of the trueness of additively manufactured mol3% zirconia crowns at different printing orientations with an industrial and…
DOI:10.1016/j.jdent.2024.104942
2024this review onlynot statednot extracted yet
Cho 2024
Trueness, physical properties, and surface characteristics of additive-manufactured zirconia crown
DOI:10.1016/j.jmbbm.2024.106536
2024this review onlynot statednot extracted yet
Frąckiewicz 2024
Comparison of Dental Zirconium Oxide Ceramics Produced Using Additive and Removal Technology for Prosthodontics and Restorative…
DOI:10.3390/ma17010168
2023this review onlynot statednot extracted yet
Giugliano 2023
In vitro comparison of physical characteristics of milled versus printed zirconia discs
DOI:10.1111/jopr.13778
2023this review onlynot statednot extracted yet
Hetzler 2025
Biaxial Flexural Strength and Vickers Hardness of 3D-Printed and Milled 5Y Partially Stabilized Zirconia
DOI:10.3390/jfb16010036
2025this review onlynot statednot extracted yet
Kessler 2024
Influence of additive and subtractive zirconia and lithium disilicate manufacturing on tensile bond strength and surface topography
DOI:10.1016/j.prosdent.2024.04.002
2024this review onlynot statednot extracted yet
Kim 2022
Microstructure, Flexural Strength, and Fracture Toughness Comparison between CAD/CAM Milled and 3D-Printed Zirconia Ceramics
DOI:10.3390/app12189088
2022this review onlynot statednot extracted yet
Kim 2023
The effect of surface treatment and low-temperature degradation on flexural strength of additive manufactured zirconia
DOI:10.1016/j.jmbbm.2023.106167
2023this review onlynot statednot extracted yet
Kyung 2024
Comparative analysis of flexural strength of 3D printed and milled 4Y-TZP and 3Y-TZP zirconia
DOI:10.1016/j.prosdent.2023.12.020
2024this review onlynot statednot extracted yet
Lou 2021
DOI:10.3760/cma.j.cn112144-20210330-00151
NRthis review onlynot statednot extracted yet
Lu 2020
Flexural strength and Weibull analysis of Y-TZP fabricated by stereolithographic additive manufacturing and subtractive manufacturing
DOI:10.1016/j.jeurceramsoc.2019.10.058
2020this review onlynot statednot extracted yet
Marsico 2020
Vat polymerization-printed partially stabilized zirconia: Mechanical properties, reliability and structural defects
DOI:10.1016/j.addma.2020.101450
2020this review onlynot statednot extracted yet
Mei 2021
An investigation of the microstructure and mechanical properties of dental zirconia manufactured by digital light processing 3D printing.
PMID:34636207
2021this review onlynot statednot extracted yet
Miura 2022
Comparative Evaluation of the Reproductive Trueness of Zirconia Crowns Fabricated Using Additive Manufacturing and Conventional Milling
DOI:10.11607/ijp.7092
2022this review onlynot statednot extracted yet
Nakai 2021
Additively Manufactured Zirconia for Dental Applications
DOI:10.3390/ma14133694
2021this review onlynot statednot extracted yet
Oh 2024
Mechanical properties and crown accuracy of additively manufactured zirconia restorations
DOI:10.1016/j.dental.2024.07.016
2024this review onlynot statednot extracted yet
Revilla‐León 2021
Flexural strength and Weibull characteristics of stereolithography additive manufactured versus milled zirconia
DOI:10.1016/j.prosdent.2020.01.019
2021this review onlynot statednot extracted yet
Revilla‐León 2022
Chemical Composition and Flexural Strength Discrepancies Between Milled and Lithography‐Based Additively Manufactured Zirconia
DOI:10.1111/jopr.13482
2022this review onlynot statednot extracted yet
Rues 2024
Effect of firing time and wall thickness on the biaxial flexural strength of 3D-printed zirconia
DOI:10.1016/j.dental.2023.12.018
2024this review onlynot statednot extracted yet
Tan 2022
Effect of high-speed sintering on the microstructure, mechanical properties and ageing resistance of stereolithographic…
DOI:10.1016/j.ceramint.2021.12.181
2022this review onlynot statednot extracted yet
Tan 2022
Physical and biological implications of accelerated aging on stereolithographic additive-manufactured zirconia for dental implant abutment
DOI:10.2186/jpr.jpr_d_21_00240
2021this review onlynot statednot extracted yet
Xiang 2021
Dental zirconia fabricated by stereolithography: Accuracy, translucency and mechanical properties in different build orientations
DOI:10.1016/j.ceramint.2021.07.044
2021this review onlynot statednot extracted yet
Yoo 2023
Mechanical properties of additively manufactured zirconia with alumina air abrasion surface treatment
DOI:10.1038/s41598-023-36181-6
2023this review onlynot statednot extracted yet
Zandinejad 2022
The Flexural Strength and Flexural Modulus of Stereolithography Additively Manufactured Zirconia with Different Porosities
DOI:10.1111/jopr.13430
2021this review onlynot statednot extracted yet
Zandinejad 2022
Surface Roughness and Bond Strength of Resin Composite to Additively Manufactured Zirconia with Different Porosities
DOI:10.1111/jopr.13434
2022this review onlynot statednot extracted yet
Zenthöfer 2022
Strength and reliability of zirconia fabricated by additive manufacturing technology
DOI:10.1016/j.dental.2022.07.004
2022this review onlynot statednot extracted yet
Zhai 2024
Zirconia specimens printed by vat photopolymerization: Mechanical properties, fatigue properties, and fractography analysis
DOI:10.1111/jopr.13942
2024this review onlynot statednot extracted yet
Zhai and Sun 2023
Research on the low-temperature degradation of dental zirconia ceramics fabricated by stereolithography
DOI:10.1016/j.prosdent.2021.11.012
2023this review onlynot statednot extracted yet

Review question

ElementPlanned (methods)Found (results)
PopulationMonolithic dental zirconia (crowns, partial restorations, disk/block specimens)Dental zirconia specimens, mostly 3Y-TZP (25 of 31 studies); 21 studies (3Y-TZP, flat specimens) in meta-analysis
InterventionAdditive manufacturing by SLA or DLPAM zirconia: DLP (18 studies), SLA (9), both (4); printing direction 0, 45, 90 degree; layer thickness 10, 25, 50 um
ComparisonSubtractive manufacturing (CIP/presintered, milled)Milled (subtractive) zirconia, mainly 3Y-TZP
OutcomesFlexural strength (primary); translucency, density, surface roughnessFlexural strength (22 studies; 12 pooled, 14 comparisons), density (7 studies pooled), surface roughness (5 studies pooled), translucency (2 studies, not pooled)
Study designsIn vitro studies31 in vitro studies (2020 to 2025); 21 in quantitative analysis
TimingNot specifiedNot applicable (in vitro)

AMSTAR 2 items

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedNoNoyes
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalYesYesyes
8Included studies described in detailYesYesyes
9Risk of bias assessed satisfactorilycriticalRCT: N/A · NRSI: Partial YesNRSI: Partial Yes · RCT: N/Ano
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: N/A · NRSI: NoNRSI: Partial Yes · RCT: N/Ano
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedYesYesyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesYesyes
OverallCritically LowLowno