Population Complete-arch implant digital impressions (in vitro models and in vivo patients)

9 findings

Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Precision: 3D deviation
Mostly in vitro models; some in vivo · Overall (IOS subgroups pooled)
SMD 1.75 [1.41, 2.10]
GRADE not reported
8 studies · 240 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Precision: 3D deviation
Mostly in vitro models; some in vivo · IOS type: TRIOS 3
SMD 2.19 [1.66, 2.72]
GRADE not reported
3 studies · 108 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Trueness: 3D deviation
Mostly in vitro models; some in vivo · Overall
SMD 2.00 [1.23, 2.77]
GRADE not reported
2 studies · 60 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Linear deviation (impression accuracy)
Mostly in vitro models; some in vivo · IOS type: TRIOS 3
SMD 0.43 [-0.08, 0.95]
GRADE not reported
2 studies · 60 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Precision: 3D deviation
Mostly in vitro models; some in vivo · IOS type: iTero Elements 5
SMD 1.64 [1.08, 2.19]
GRADE not reported
2 studies · 90 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Trueness: angular deviation
Mostly in vitro models; some in vivo · Overall
SMD 1.92 [1.18, 2.66]
GRADE not reported
2 studies · 60 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Precision: angular deviation
Mostly in vitro models; some in vivo · Overall (IOS subgroups pooled)
SMD 0.86 [0.45, 1.27]
GRADE not reported
3 studies · 112 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Linear deviation (impression accuracy)
Mostly in vitro models; some in vivo · Overall (IOS subgroups pooled)
SMD 0.33 [-0.11, 0.77]
GRADE not reported
3 studies · 82 participants
Stereophotogrammetry-based scanner (mainly PIC)Intraoral scanners (IOS)Precision: 3D deviation
Mostly in vitro models; some in vivo · IOS type: TRIOS 4
SMD 0.82 [0.00, 1.64]
GRADE not reported
2 studies · 32 participants

Included primary studies 25

Open in Studies
StudyYearAlso included byOutcomes it informs hereTrial data
Cheng 2024
Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and…
PMID:38421115
20241 other reviewnot statednot extracted yet
Kosago 2023
Comparison of the accuracy between conventional and various digital implant impressions for an implant-supported mandibular complete…
PMID:36083233
20231 other reviewnot statednot extracted yet
Ma 2021
Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in…
PMID:34893053
20211 other reviewnot statednot extracted yet
Pozzi 2023
Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective…
PMID:37485737
20231 other reviewnot statednot extracted yet
Cheng 2024
Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and…
DOI:10.1111/clr.14252
2024this review onlynot statednot extracted yet
Fu 2023
Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete‐arch…
DOI:10.1111/clr.14183
2023this review onlynot statednot extracted yet
Fu 2024
Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch…
PMID:37746813
2024this review onlynot statednot extracted yet
Kosago 2023
Comparison of the accuracy between conventional and various digital implant impressions for an implant‐supported mandibular complete…
DOI:10.1111/jopr.13604
2022this review onlynot statednot extracted yet
Ma 2021
Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in…
DOI:10.1186/s12903-021-02005-0
2021this review onlynot statednot extracted yet
Orejas-Perez 2022
In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems
DOI:10.3390/ijerph19074300
2022this review onlynot statednot extracted yet
Orejas-Perez 2022
In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems.
PMID:35409985
2022this review onlynot statednot extracted yet
Pinto 2023
Accuracy of different digital acquisition methods in complete arch implant-supported prostheses: An in vitro study
DOI:10.1016/j.prosdent.2023.07.008
2024this review onlynot statednot extracted yet
Pinto 2024
Accuracy of different digital acquisition methods in complete arch implant-supported prostheses: An in vitro study.
PMID:37620183
2024this review onlynot statednot extracted yet
Pozzi 2023
Accuracy of complete‐arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective…
DOI:10.1111/clr.14141
2023this review onlynot statednot extracted yet
Pozzi 2024
Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An <i>in…
DOI:10.2186/jpr.jpr_d_22_00251
2023this review onlynot statednot extracted yet
Pozzi 2024
Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study.
PMID:37574278
2024this review onlynot statednot extracted yet
Revilla-Leon 2021
Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with…
DOI:10.1016/j.prosdent.2020.03.005
2021this review onlynot statednot extracted yet
Revilla-Leon 2021
Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with…
PMID:32386912
2021this review onlynot statednot extracted yet
Sallorenzo 2022
Comparative study of the accuracy of an implant intraoral scanner and that of a conventional intraoral scanner for complete-arch fixed…
DOI:10.1016/j.prosdent.2021.01.032
2022this review onlynot statednot extracted yet
Sallorenzo 2022
Comparative study of the accuracy of an implant intraoral scanner and that of a conventional intraoral scanner for complete-arch fixed…
PMID:33836855
2022this review onlynot statednot extracted yet
Tohme 2021
matched by author and year (probable)
NRthis review onlynot statednot extracted yet
Tohme 2023
Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch…
DOI:10.1016/j.prosdent.2021.05.006
2023this review onlynot statednot extracted yet
Tohme 2023
Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch…
PMID:34112521
2023this review onlynot statednot extracted yet
Yan 2023
Accuracy of 2 direct digital scanning techniques—intraoral scanning and stereophotogrammetry—for complete arch implant-supported fixed…
DOI:10.1016/j.prosdent.2022.03.033
2023this review onlynot statednot extracted yet
Yan 2023
Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed…
PMID:35667889
2023this review onlynot statednot extracted yet

Overlap with other reviews

Reviews that include the same primary studies are not independent evidence. Shared counts match studies by PMID, DOI or NCT, and otherwise by author and year (a probable match). Only the non-Cochrane dental reviews have study lists, so overlap with Cochrane reviews is not counted yet.

Review question

ElementPlanned (methods)Found (results)
PopulationComplete-arch implant impressions (human or in vitro models)Complete-arch implant models (9 in vitro studies) and edentulous arches (4 in vivo studies)
InterventionStereophotogrammetry-based dental scannersPIC dental scanner (stereophotogrammetry) pooled; ICam4D studies not pooled
ComparisonIntraoral scanners (IOS)Intraoral scanners: TRIOS 3, TRIOS 4, iTero Element 2 and 5 (8 studies in quantitative analysis)
OutcomesAccuracy (trueness and precision; linear, 3D and angular deviations)Linear deviation, trueness (3D, angular) and precision (3D, angular) pooled as standardized mean differences (fixed effect)
Study designsIn vitro and in vivo studies published in English up to September 2024; animal studies, unpublished reports, theses and case reports excluded13 studies in qualitative synthesis (9 in vitro, 4 in vivo); 8 in meta-analysis
TimingNot specifiedNot specified