Non-Cochrane · intervention · PM29466366

Meta-analysis of the clinical behavior of posterior direct resin restorations: Low polymerization shrinkage resin in comparison to methacrylate composite resin.

Kruly Paula de Castro, Giannini Marcelo, Pascotto Renata Corrêa, et al. · PloS one · 2018 · PubMed · doi:10.1371/journal.pone.0191942

Oral HealthDental cariesAMSTAR 2: critically low (both extractors)
Full textEvery question was extracted from the full text, figures and supplements by two independent LLM extractors, disagreements adjudicated. Rows cite where in the review the value comes from.
Questions
15
current version
GRADE rated
0
No studies
0
Included studies
23
linked below
No studies 0 · 0%Ungraded 15 · 100%Very low 0 · 0%Low 0 · 0%Moderate 0 · 0%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Review question

ElementPlanned (methods)Found (results)
PopulationPatients with class I or II restorations in permanent (posterior) teethPeople with permanent posterior teeth restored with class I/II restorations (21 RCTs)
InterventionResin composites with monomers designed to reduce polymerization shrinkage (e.g., silorane, ormocer, bulk-fill, or other modified/new monomers)Low polymerization shrinkage composites: silorane (13 studies), ormocer (4), bulk-fill (3), InTen-S (1)
ComparisonConventional methacrylate-based (BIS-GMA/dimethacrylate) resin compositeConventional methacrylate-based resin composite
OutcomesMarginal integrity/adaptation, marginal discoloration, recurrent (secondary) caries, retention, postoperative sensitivityMarginal adaptation, marginal discoloration, secondary caries, retention, postoperative sensitivity (5 outcomes)
Study designsRandomized controlled clinical trials21 randomized controlled clinical trials (20 included in the meta-analysis; 1 excluded for lacking results-table data)
TimingAt least 6 months follow-upFollow-up 12, 18, 24, 36 and 60 months (longest 60 months)

Search date: Not specified. Databases: PubMed; Web of Science; EMBASE; Scopus; Lilacs

Questions and results

Low polymerization shrinkage resin composite (silorane, ormocer, bulk-fill or other modified-monomer composite) vs Conventional methacrylate-based resin composite

Population: People with permanent posterior teeth restored with class I or II direct restorations
15 questions
OutcomeEffectEvidenceStatus / GRADE
Marginal adaptation (clinically detectable deterioration)
36 months
At 36 months, marginal adaptation did not differ significantly between the composites (6 groups; ungraded).
Source: Results (Marginal adaptation) · same question in other reviews
Five articles (six experimental groups) evaluated marginal adaptation after 36 months; results were mixed and the overall meta-analytic effect was not statistically significant.5 studiesUngraded
Marginal discoloration
24 months
At 24 months, marginal discoloration did not differ significantly (7 groups; p = 0.77; ungraded).
Source: Results (Marginal discoloration); Fig 8 · same question in other reviews
Odds ratio (OR) 1.08 [0.64, 1.84]6 studiesUngraded
Marginal adaptation (clinically detectable deterioration)
60 months
At 60 months, marginal adaptation did not differ significantly between the composites (4 groups; ungraded).
Source: Results (Marginal adaptation) · same question in other reviews
Three articles (four experimental groups) evaluated marginal adaptation after 60 months; two favored the experimental group but the overall meta-analytic effect was not statistically significant.3 studiesUngraded
Marginal adaptation (clinically detectable deterioration)
18 months
At 18 months, marginal adaptation did not differ significantly between low polymerization shrinkage and methacrylate composites (2 studies; not statistically significant; ungraded).
Source: Results (Marginal adaptation) · same question in other reviews
Only two studies, both testing silorane composites, evaluated marginal adaptation after 18 months; one favored the experimental group and one the control group, and the overall meta-analytic effect was not…2 studiesUngraded
Secondary caries
24 months
No secondary caries was reported at 24 months in any of seven studies, so no meta-analysis was possible (ungraded).
Source: Results (Secondary caries) · same question in other reviews
After 24 months, seven articles evaluated secondary caries, but none reported any secondary caries in either group; a meta-analysis was therefore not conducted.7 studiesUngraded
Secondary caries
12 months
Secondary caries at 12 months did not differ significantly between low polymerization shrinkage and methacrylate composites (OR 1.51, 95% CI 0.64 to 3.57; Moderate certainty).
Source: Table 3 (Summary of findings); Fig 6; Results (Secondary caries) · same question in other reviews
OR 1.51 [0.64, 3.57]14 studies · 2087 participantsUngraded
Marginal discoloration
60 months
At 60 months, marginal discoloration did not differ significantly (3 groups; ungraded).
Source: Results (Marginal discoloration) · same question in other reviews
Two articles (three experimental groups) evaluated marginal discoloration after 60 months; the meta-analysis showed no difference in the overall effect.2 studiesUngraded
Retention (restoration loss)
24 months
At 24 months, retention did not differ significantly between the composites (6 studies; ungraded).
Source: Results (Retention) · same question in other reviews
Six articles assessed restoration retention after 24 months; four showed no loss of retention in either group and two favored the control group, with no difference in the overall meta-analytic effect.6 studiesUngraded
Postoperative sensitivity
12 months
Postoperative sensitivity at 12 months did not differ significantly between low polymerization shrinkage and methacrylate composites (OR 1.65, 95% CI 0.71 to 3.81; Moderate certainty).
Source: Table 3 (Summary of findings); Results (Postoperative sensitivity) · same question in other reviews
OR 1.65 [0.71, 3.81]10 studies · 970 participantsUngraded
Retention (restoration loss)
12 months
Retention at 12 months did not differ significantly between low polymerization shrinkage and methacrylate composites (OR 0.83, 95% CI 0.33 to 2.09; Moderate certainty).
Source: Table 3 (Summary of findings); Fig 9; Results (Retention) · same question in other reviews
OR 0.83 [0.33, 2.09]11 studies · 1834 participantsUngraded
Marginal discoloration
12 months
Marginal discoloration at 12 months did not differ significantly between low polymerization shrinkage and methacrylate composites (OR 1.53, 95% CI 0.98 to 2.41; Moderate certainty).
Source: Table 3 (Summary of findings); Fig 7; Results (Marginal discoloration) · same question in other reviews
OR 1.53 [0.98, 2.41]13 studies · 2082 participantsUngraded
Marginal discoloration
18 months
At 18 months, marginal discoloration did not differ significantly between the composites (2 studies; ungraded).
Source: Results (Marginal discoloration) · same question in other reviews
Only two articles, both testing silorane resins, evaluated marginal discoloration after 18 months; one favored the experimental group and one the control group, with the meta-analysis showing no difference in the…2 studiesUngraded
Postoperative sensitivity
24 months
At 24 months, postoperative sensitivity did not differ significantly between the composites (7 groups; ungraded).
Source: Results (Postoperative sensitivity) · same question in other reviews
Six articles (seven experimental groups) evaluated postoperative sensitivity after 24 months; four showed no sensitivity in either group and three favored the control group, but the overall meta-analytic effect was not…6 studiesUngraded
Marginal adaptation (clinically detectable deterioration)
12 months
Conventional methacrylate composites had significantly better 12-month marginal adaptation than low polymerization shrinkage composites (OR 1.77, 95% CI 1.25 to 2.50; Moderate certainty).
Source: Table 3 (Summary of findings); Fig 4; Results (Marginal adaptation); Abstract · same question in other reviews
OR 1.77 [1.25, 2.50]15 studies · 2280 participantsUngraded
Marginal adaptation (clinically detectable deterioration)
24 months
At 24 months, marginal adaptation did not differ significantly between the composites (8 groups; p = 0.11; ungraded).
Source: Results (Marginal adaptation); Fig 5 · same question in other reviews
Odds ratio (OR) 1.46 [0.92, 2.33]7 studiesUngraded

AMSTAR 2 appraisal

Two independent extractors rated each item. Their ratings are shown side by side because they have not been reconciled yet. The overall rating follows Shea et al. 2017: one critical flaw gives Low, more than one gives Critically Low.

ItemExtractor AExtractor BAgree
1Research question includes PICO componentsYesYesyes
2Protocol established before the reviewcriticalPartial YesPartial Yesyes
3Choice of study designs explainedYesNono
4Comprehensive literature searchcriticalPartial YesPartial Yesyes
5Study selection in duplicateYesYesyes
6Data extraction in duplicateYesYesyes
7List of excluded studies with reasonscriticalNoNoyes
8Included studies described in detailPartial YesPartial Yesyes
9Risk of bias assessed satisfactorilycriticalRCT: Yes · NRSI: N/ANRSI: N/A · RCT: Yesno
10Funding of included studies reportedNoNoyes
11Appropriate meta-analysis methodscriticalRCT: Yes · NRSI: N/ANRSI: N/A · The report states that RevMan was used but does not describe pooling methods, heterogeneity assessment, or why the meta-analysis methods were appropriate.: Nono
12Impact of risk of bias on the pooled resultsNoNoyes
13Risk of bias accounted for in interpretationcriticalYesYesyes
14Heterogeneity explainedNoNoyes
15Publication bias investigatedcriticalNoNoyes
16Conflicts of interest reportedYesNono
OverallCritically LowCritically Lowyes

Included primary studies 23

Open as a trial list
StudyAlso included byOutcomes it informs hereTrial PICOResults
Attia et al. 2014
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Baracco et al. 2012
Clinical Evaluation of a Low-shrinkage Composite in Posterior Restorations: One-Year Results
DOI:10.2341/11-179-c
this review onlynot statednot extracted yetnot extracted yet
Baracco et al. 2013
Two-Year Clinical Performance of a Low-Shrinkage Composite in Posterior Restorations
DOI:10.2341/12-364-c
this review onlynot statednot extracted yetnot extracted yet
Bayraktar et al. 2016
One‐year clinical evaluation of different types of bulk‐fill composites
DOI:10.1111/jicd.12210
this review onlynot statednot extracted yetnot extracted yet
Beck et al. 2014
One-year evaluation of two hybrid composites placed in a randomized-controlled clinical trial
DOI:10.1016/j.dental.2014.05.006
this review onlynot statednot extracted yetnot extracted yet
Bottenberg 2007
DOI:10.1016/j.dental.2006.07.002
this review onlynot statednot extracted yetnot extracted yet
Bottenberg et al. 2007
A prospective randomised clinical trial of one bis-GMA-based and two ormocer-based composite restorative systems in class II cavities:…
DOI:10.1016/j.jdent.2006.07.002
this review onlynot statednot extracted yetnot extracted yet
Bottenberg et al. 2009
A prospective randomized clinical trial of one bis-GMA-based and two ormocer-based composite restorative systems in class II cavities:…
DOI:10.1016/j.jdent.2008.11.011
this review onlynot statednot extracted yetnot extracted yet
Efes et al. 2006
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Efes et al. 2013
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
El-Eraky et al. 2014
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Gasparello et al. 2016
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Gonçalves 2013
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Goncalves et al. 2013
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Karaman et al. 2016
Three-year clinical evaluation of class II posterior composite restorations placed with different techniques and flowable composite…
DOI:10.1007/s00784-016-1940-y
this review onlynot statednot extracted yetnot extracted yet
Mahmoud et al. 2014
DOI:10.3290/j.jad.a31939
this review onlynot statednot extracted yetnot extracted yet
Santos et al. 2014
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Schmidt et al. 2011
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
Schmidt et al. 2015
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
van Dijken and Lindberg 2009
matched by author and year (probable)
this review onlynot statednot extracted yetnot extracted yet
van Dijken and Pallesen 2014
A randomized controlled three year evaluation of “bulk-filled” posterior resin restorations based on stress decreasing resin technology
DOI:10.1016/j.dental.2014.05.028
this review onlynot statednot extracted yetnot extracted yet
Walter et al. 2014
Three‐Year Clinical Evaluation of a Silorane Composite Resin
DOI:10.1111/jerd.12077
this review onlynot statednot extracted yetnot extracted yet
Yazici et al. 2014
Three-year Clinical Evaluation of Different Restorative Resins in Class I Restorations
DOI:10.2341/13-221-c
this review onlynot statednot extracted yetnot extracted yet