Cochrane · systematic review · CD013660

Continuous positive airway pressure (CPAP) for apnoea of prematurity

Ho, JJ, Zakarija-Grkovic, I, Lok, JW, et al. · Cochrane Database of Systematic Reviews · 2023 · Cochrane Library

NeonatalAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
15
current version
GRADE rated
3
No studies
10
Included studies
NR
No studies 10 · 66.7%Ungraded 2 · 13.3%Very low 3 · 20%Low 0 · 0%Moderate 0 · 0%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

CPAP and supportive care compared to supportive care for apnoea of prematurity

Population: preterm infants with apnoea of prematurity
4 questions
OutcomeEffectEvidenceStatus / GRADE
Failed CPAP
CPAP and supportive care vs supportive care
no estimate extractedNRNo studies
Mean apnoea events
CPAP and supportive care vs supportive care
no estimate extractedNRNo studies
Adverse events
CPAP and supportive care vs supportive care
no estimate extractedNRNo studies
Long‐term neurodevelopmental outcomes
CPAP and supportive care vs supportive care
no estimate extractedNRNo studies

Variable flow compared to ventilator CPAP for apnoea of prematurity

Population: preterm infants with apnoea of prematurity (median age 9 days)
3 questions
OutcomeEffectEvidenceStatus / GRADE
Failed CPAP (defined as need for mechanical ventilation)
Variable flow vs ventilator CPAP
RR 0.16 [0.01, 2.9]1 study · 26 participantsVery low
Downgraded: risk of bias
Mean apnoea events (apnoea > 20 seconds with or without bradycardia or desaturation) Mean per 4‐hour interval
Variable flow vs ventilator CPAP
no estimate extracted1 study · 26 participantsVery low
Downgraded: risk of bias
Long‐term neurodevelopmental outcomes
Variable flow vs ventilator CPAP
no estimate extractedNRNo studies

Variable flow compared to bubble CPAP for apnoea of prematurity

Population: preterm infants, 24 to 29 weeks gestation and mean age 18 days with apnoea of prematurity
4 questions
OutcomeEffectEvidenceStatus / GRADE
Failed CPAP
Variable flow vs bubble CPAP
no estimate extractedNRNo studies
Mean apnoea events
Variable flow vs bubble CPAP
no estimate extractedNRNo studies
Adverse events
Variable flow vs bubble CPAP
no estimate extractedNRNo studies
Long‐term neurodevelopmental outcomes
Variable flow vs bubble CPAP
no estimate extractedNRNo studies

Infant Flow CPAP compared to Medijet CPAP for apnoea of prematurity

Population: preterm infants with apnoea of prematurity (gestation 27 weeks, age not stated)
4 questions
OutcomeEffectEvidenceStatus / GRADE
Failed CPAP
Infant Flow CPAP vs Medijet CPAP
RR 2.62 [0.91, 7.53]1 study · 80 participantsVery low
Downgraded: risk of bias
Mean apnoea events
Infant Flow CPAP vs Medijet CPAP
no estimate extracted24 participantsUngraded
Adverse events
Infant Flow CPAP vs Medijet CPAP
22 participantsUngraded
Long‐term neurodevelopmental outcomes
Infant Flow CPAP vs Medijet CPAP
no estimate extractedNRNo studies