Cochrane · systematic review · CD013353

Non‐pharmacological interventions for the prevention of pain during endotracheal suctioning in ventilated neonates

Pirlotte, S, Beeckman, K, Ooms, I, et al. · Cochrane Database of Systematic Reviews · 2024 · Cochrane Library

NeonatalAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
23
current version
GRADE rated
11
No studies
12
Included studies
NR
No studies 12 · 52.2%Ungraded 0 · 0%Very low 0 · 0%Low 10 · 43.5%Moderate 1 · 4.3%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Facilitated tucking / four‐handed care / gentle human touch compared with standard care for pain during endotracheal suctioning

Population: neonates with mechanical ventilation
9 questions
OutcomeEffectEvidenceStatus / GRADE
Validated pain scales
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extractedNRNo studies
PIPP during endotracheal suctioning Range of scale 0 to 21. Lower score = less pain
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extracted4 studies · 148 participantsModerate
Downgraded: risk of bias
Physiological indicators
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extractedNRNo studies
Heart rate
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extracted2 studies · 80 participantsLow
Downgraded: risk of bias, imprecision
SaO 2 during endotracheal suctioning
Facilitated tucking / four‐handed care / gentle human touch vs standard care
MD 0.872 studies · 80 participantsLow
Downgraded: risk of bias, imprecision
Behavioural indicators
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extractedNRNo studies
SDB during endotracheal suctioning
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extracted1 study · 20 participantsLow
Downgraded: risk of bias, imprecision
SRB during endotracheal suctioning
Facilitated tucking / four‐handed care / gentle human touch vs standard care
MD 0.9 [0.2, 1.6]1 study · 20 participantsLow
Downgraded: risk of bias, imprecision
—
Facilitated tucking / four‐handed care / gentle human touch vs standard care
no estimate extractedNRNo studies

Familiar odour (breast milk smell) compared with standard care for pain during endotracheal suctioning

Population: neonates with mechanical ventilation
7 questions
OutcomeEffectEvidenceStatus / GRADE
Validated pain scores
Familiar odour (breast milk smell) vs standard care
no estimate extractedNRNo studies
PIPP during endotracheal suctioning Range of scale 0 to 21. Lower score = less pain
Familiar odour (breast milk smell) vs standard care
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision
Physiological indicators
Familiar odour (breast milk smell) vs standard care
no estimate extractedNRNo studies
Heart rate
Familiar odour (breast milk smell) vs standard care
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision
SaO 2 during endotracheal suctioning
Familiar odour (breast milk smell) vs standard care
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision
Behavioural indicators
Familiar odour (breast milk smell) vs standard care
no estimate extractedNRNo studies
—
Familiar odour (breast milk smell) vs standard care
no estimate extractedNRNo studies

White noise compared with standard care for pain during endotracheal suctioning

Population: neonates with mechanical ventilation
7 questions
OutcomeEffectEvidenceStatus / GRADE
Validated pain scores
White noise vs standard care
no estimate extractedNRNo studies
PIPP during endotracheal suctioning Range of scale 0 to 21 Lower score = less pain
White noise vs standard care
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision
Physiological indicators
White noise vs standard care
no estimate extractedNRNo studies
Heart rate
White noise vs standard care
no estimate extracted1 study · 40 participantsLow
Downgraded: risk of bias, imprecision
SaO 2
White noise vs standard care
MD 2.251 study · 40 participantsLow
Downgraded: risk of bias, imprecision
Behavioural indicators
White noise vs standard care
no estimate extractedNRNo studies
—
White noise vs standard care
no estimate extractedNRNo studies