Cochrane · systematic review · CD010342

Interventions to improve hearing aid use in adult auditory rehabilitation

Barker, F, Mackenzie, E, Elliott, L, et al. · Cochrane Database of Systematic Reviews · 2016 · Cochrane Library

ENT2 versionsAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
21
current version
GRADE rated
15
No studies
6
Included studies
NR
No studies 6 · 28.6%Ungraded 0 · 0%Very low 11 · 52.4%Low 4 · 19%Moderate 0 · 0%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Current version only

Self‐management support interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB3 (current) · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence
no estimate extractedNRNo studies
Daily hours of hearing aid use
no estimate extractedNRNo studies
Adverse effects
no estimate extractedNRNo studies
Quality of life Validated self‐report measures. WHODAS 2.0 scale from: 0 to 100
no estimate extracted1 study · 35 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Self‐reported hearing handicap Validated self‐report measure: HHIE (Ventry 1982) scale from 0 to 100
no estimate extracted2 studies · 87 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Hearing aid benefit
no estimate extractedNRNo studies
Communication Validated self‐report measure: verbal subscale of the CPHI (Demorest 1987) scale from 0 to 5
no estimate extracted1 study · 52 participantsVery low
Downgraded: risk of bias, imprecision, indirectness

Delivery system design interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB3 (current) · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence Number of people fitted with hearing aid/number of people who use the aids
RR 1.02 [0.99, 1.05]2 studies · 686 participantsLow
Downgraded: indirectness
Daily hours of hearing aid use Average self‐reported or data‐logged hours of use per day. Scale from: 0 to 12 hours
no estimate extracted4 studies · 700 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Adverse effects Number of outstanding complaints
RR 0.75 [0.5, 1.12]1 study · 98 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Quality of life
no estimate extractedNRNo studies
Self‐reported hearing handicap Validated self‐report measure HHIE scale from: 0 to 100 (Ventry 1982)
no estimate extracted2 studies · 628 participantsVery low
Downgraded: imprecision, indirectness
Hearing aid benefit Validated self‐report measure. Outer EAR scale from: 0 to 100
no estimate extracted1 study · 582 participantsVery low
Downgraded: imprecision, indirectness
Communication Validated self‐report measure: verbal subscale of the CPHI scale from 0 to 5 (Demorest 1987)
no estimate extracted1 study · 588 participantsVery low
Downgraded: imprecision, indirectness

Combined self‐management support/delivery system design interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB3 (current) · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence Number of people fitted with hearing aid/number of people who use the aids
RR 1.06 [1, 1.12]1 study · 162 participantsLow
Downgraded: imprecision, indirectness
Daily hours of hearing aid use Self‐reported or data‐logged average hours of use per day. Scale from: 0 to 12 hours
no estimate extracted2 studies · 69 participantsVery low
Downgraded: imprecision, inconsistency
Adverse effects
no estimate extractedNRNo studies
Quality of life Validated self‐report measures. IOI‐HA item 7 scale from: 1 to 5
no estimate extracted2 studies · 69 participantsLow
Downgraded: imprecision
Self‐reported hearing handicap Validated self‐report measures
no estimate extracted3 studies · 88 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Hearing aid benefit Validated self‐report measures (IOI‐HA item 4). Scale from: 1 to 5
no estimate extracted2 studies · 69 participantsLow
Downgraded: imprecision
Use of verbal communication strategy Validated self‐report measures (verbal subscale of the CPHI (Demorest 1987)). Scale from: 0 to 5
no estimate extracted1 study · 34 participantsVery low
Downgraded: imprecision, indirectness

Self management support interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB2 · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence
no estimate extractedNRNo studies
Daily hours of hearing aid use
no estimate extractedNRNo studies
Adverse effects
no estimate extractedNRNo studies
Quality of life Validated self report measures. WHODAS 2.0 scale from: 0 to 100
no estimate extracted1 study · 35 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Self reported hearing handicap Validated self report measure: HHIE (Ventry 1982) scale from 0 to 100
no estimate extracted2 studies · 87 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Hearing aid benefit
no estimate extractedNRNo studies
Communication Validated self report measure: verbal subscale of the CPHI (Demorest 1987) scale from 0 to 5
no estimate extracted1 study · 52 participantsVery low
Downgraded: risk of bias, imprecision, indirectness

Delivery system design interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB2 · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence Number of people fitted with hearing aid/number of people who use the aids
RR 1.02 [0.99, 1.05]2 studies · 686 participantsLow
Downgraded: indirectness
Daily hours of hearing aid use Average self reported or data‐logged hours of use per day. Scale from: 0 to 12 hours
no estimate extracted4 studies · 700 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Adverse effects Number of outstanding complaints
RR 0.75 [0.5, 1.12]1 study · 98 participantsVery low
Downgraded: risk of bias, imprecision, indirectness
Quality of life
no estimate extractedNRNo studies
Self reported hearing handicap Validated self report measure HHIE (Ventry 1982) scale from: 0 to 100
no estimate extracted2 studies · 628 participantsVery low
Downgraded: imprecision, indirectness
Hearing aid benefit Validated self report measure. Outer EAR scale from: 0 to 100
no estimate extracted1 study · 582 participantsVery low
Downgraded: imprecision, indirectness
Communication Validated self report measure: verbal subscale of the CPHI (Demorest 1987) scale from 0 to 5
no estimate extracted1 study · 588 participantsVery low
Downgraded: imprecision, indirectness

Combined self management support/delivery system design interventions for adults with hearing loss who use hearing aids

Population: adults with hearing loss who use hearing aids
CD010342.PUB2 · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Adherence
no estimate extractedNRNo studies
Daily hours of hearing aid use Self reported or data‐logged average hours of use per day Scale from: 0 to 12 hours
no estimate extracted2 studies · 69 participantsVery low
Downgraded: imprecision, inconsistency
Adverse effects
no estimate extractedNRNo studies
Quality of life Validated self report measures. IOI‐HA item 7 scale from: 1 to 5
no estimate extracted2 studies · 69 participantsLow
Downgraded: imprecision
Self reported hearing handicap Validated self report measures
no estimate extracted3 studies · 88 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Hearing aid benefit Validated self report measures (IOI‐HA item 4) Scale from: 1 to 5
no estimate extracted2 studies · 69 participantsLow
Downgraded: imprecision
Use of verbal communication strategy Validated self report measures (verbal subscale of the CPHI (Demorest 1987)) scale from: 0 to 5
no estimate extracted1 study · 34 participantsVery low
Downgraded: imprecision, indirectness