Cochrane · systematic review · CD009771

Protocol‐directed sedation versus non‐protocol‐directed sedation in mechanically ventilated intensive care adults and children

Aitken, LM, Bucknall, T, Kent, B, et al. · Cochrane Database of Systematic Reviews · 2018 · Cochrane Library

Emergency and Critical Care2 versionsAMSTAR 2: not assessed
SoF tableOnly the outcomes this review put in its Summary of Findings table are listed (the Cochrane Handbook caps them at about seven per comparison). Its other analyses are not shown here.
Questions
8
current version
GRADE rated
8
No studies
0
Included studies
NR
No studies 0 · 0%Ungraded 0 · 0%Very low 0 · 0%Low 6 · 75%Moderate 1 · 12.5%High 1 · 12.5%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Questions and results

Current version only

Protocol‐directed sedation management compared with usual care for sedation management in mechanically ventilated intensive care unit patients

Population: mechanically ventilated ICU adults and children requiring sedation management
CD009771.PUB3 (current) · 8 questions
OutcomeEffectEvidenceStatus / GRADE
Duration of mechanical ventilation (measured in hours for the entire duration of the first ICU stay for each patient)
Protocol‐directed sedation management vs usual care
no estimate extracted4 studies · 3283 participantsLow
Downgraded: risk of bias, inconsistency
ICU mortality
Protocol‐directed sedation management vs usual care
RR 0.77 [0.39, 1.5]2 studies · 513 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Hospital mortality
Protocol‐directed sedation management vs usual care
RR 0.9 [0.72, 1.13]3 studies · 3082 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
ICU length of stay (days)
Protocol‐directed sedation management vs usual care
no estimate extracted4 studies · 3128 participantsLow
Downgraded: risk of bias, inconsistency
Hospital length of stay (days)
Protocol‐directed sedation management vs usual care
no estimate extracted3 studies · 2927 participantsModerate
Downgraded: risk of bias, imprecision, inconsistency
Adverse event ‐ incidence of self‐extubation (in ICU)
Protocol‐directed sedation management vs usual care
RR 0.88 [0.55, 1.42]2 studies · 2761 participantsHigh
Adverse event ‐ incidence of reintubation (in ICU)
Protocol‐directed sedation management vs usual care
RR 0.65 [0.35, 1.24]1 study · 321 participantsLow
Downgraded: risk of bias, imprecision
Incidence of tracheostomy (in ICU)
Protocol‐directed sedation management vs usual care
RR 0.67 [0.35, 1.3]3 studies · 3082 participantsLow
Downgraded: risk of bias, inconsistency

Protocol‐directed sedation management compared with usual care for sedation management in mechanically ventilated intensive care unit patients

Population: mechanically ventilated ICU patients requiring sedation management
CD009771.PUB2 · 6 questions
OutcomeEffectEvidenceStatus / GRADE
Duration of mechanical ventilation (hours)
Protocol‐directed sedation management vs usual care
no estimate extracted2 studies · 633 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
ICU mortality
Protocol‐directed sedation management vs usual care
RR 1.04 [0.67, 1.61]1 study · 312 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Hospital mortality
Protocol‐directed sedation management vs usual care
RR 0.96 [0.71, 1.31]2 studies · 633 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Adverse event ‐ incidence of re‐intubation
Protocol‐directed sedation management vs usual care
RR 0.65 [0.35, 1.24]1 study · 321 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Adverse event ‐ incidence of self extubation
Protocol‐directed sedation management vs usual care
RR 2.08 [0.19, 22.69]1 study · 312 participantsLow
Downgraded: risk of bias, imprecision, inconsistency
Incidence of tracheostomy
Protocol‐directed sedation management vs usual care
RR 0.77 [0.31, 1.89]2 studies · 633 participantsLow
Downgraded: risk of bias, imprecision, inconsistency