Initial arch wires used in orthodontic treatment with fixed appliances
Liu, C, Wei, Z, Jian, F, et al. · Cochrane Database of Systematic Reviews · 2024 · Cochrane Library
Full textEvery question was extracted from the full review (methods and results), not only its Summary of Findings table.
Questions
34
current version
GRADE rated
12
No studies
16
Included studies
29
as reported
No studies 16 · 47.1%Ungraded 6 · 17.6%Very low 3 · 8.8%Low 7 · 20.6%Moderate 2 · 5.9%High 0 · 0%
Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.
Review question
| Element | Planned (methods) | Found (results) |
|---|---|---|
| Population | Participants of any age with full-arch fixed orthodontic appliances on the upper arch, lower arch, or both. Excluded: concurrent palatal expansion or extraoral appliances, previous active orthodontic treatment, or relevant medical history. | 1915 participants (2581 arches) from 29 RCTs; sample sizes 14 to 200 participants; 13 studies included children/adolescents and adults, 13 only children/adolescents, 2 only adults. |
| Intervention | Initial arch wire (one material, cross-sectional shape or size) | Materials evaluated: conventional and multistrand stainless steel; conventional, single-strand superelastic, coaxial/multistrand superelastic, ion-implanted superelastic, coated superelastic, thermoelastic (with and without copper) NiTi; and TiNbTaZr; in sizes 0.012 to 0.018 inch |
| Comparison | Initial arch wires (first arch wire inserted into the fixed appliance at the beginning of treatment; excludes later arch wires), compared in terms of: (1) material; (2) cross-sectional shape; (3) cross-sectional size | Comparators drawn from the same set of stainless steel and NiTi wire types and sizes |
| Outcomes | Primary outcomes: alignment rate (tooth movement over a period of time); incidence/prevalence and amount of root resorption. Secondary outcomes: time to next/working arch wire; time to alignment; pain (intensity on VAS or categorical scale, and duration; analgesic consumption) | Alignment rate (n=20); Root resorption (n=3); Time to next/working arch wire (n=2); Time to alignment (n=3); Pain intensity (n=13) |
| Study designs | Randomised controlled trials | Randomised controlled trials (n=29) |
| Timing | Not reported | 3 days to 6 months |
Search date: 2022-07-04. Databases: Cochrane Oral Health's Trials Register; Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE Ovid; Embase Ovid; US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov; World Health Organization International Clinical Trials Registry Platform
Questions and results
Current version onlySuperelastic NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to next/working arch wire | No studies reported time to next/working arch wire | 0 studies | No studies |
Root resorption | Root resorption: not reported | 0 studies | No studies |
Time to alignment | Cobb 1998 measured time to alignment but reported results only as graphs, with no numerical data | 1 study | Ungraded |
Pain day 1 7 to 14 days | MD 2.68 [-1.38, 6.75] 2.68 [-1.38, 6.75] mm (VAS; superelastic higher) | 2 studies · 127 participants | Low Downgraded: risk of bias, imprecision |
Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to alignment | Time to alignment: not reported | 0 studies | No studies |
Pain day 1 3 to 7 days | MD 0.29 [-0.52, 1.10] 0.29 [-0.52, 1.10] mm (VAS; superelastic higher) | 2 studies · 142 participants | Low Downgraded: risk of bias, imprecision |
Time to next/working arch wire | MD 0.40 [-0.10, 0.90] | 1 study · 88 participants | Ungraded |
Root resorption | Root resorption: not reported | 0 studies | No studies |
Alignment rate 5 to 10 weeks | Conventional NiTi vs superelastic NiTi (O'Brien 1990; Ong 2011); not pooled due to clinical heterogeneity; little or no difference in alignment rate | 2 studies · 124 participants | Low Downgraded: risk of bias, imprecision |
Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Pain | Pain: not reported | 0 studies | No studies |
Alignment rate 4 weeks | MD 0.10 [-0.95, 1.15] 0.10 [-0.95, 1.15] mm/4 weeks (CuNiTi faster) | 1 study · 66 participants | Very low Downgraded: risk of bias, imprecision |
Time to next/working arch wire | MD 0.00 [-0.51, 0.51] | 1 study · 86 participants | Ungraded |
Time to alignment (alignment rate ratio) 6 months | HR 1.30 [0.68, 2.50] | 1 study · 60 participants | Low Downgraded: imprecision |
Root resorption | Root resorption: not reported | 0 studies | No studies |
Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to alignment | Time to alignment: not reported | 0 studies | No studies |
Time to next/working arch wire | No studies reported time to next/working arch wire | 0 studies | No studies |
Alignment rate 4 weeks | MD -2.64 [-4.61, -0.67] -2.64 [-4.61, -0.67] mm/4 weeks | 2 studies · 64 participants | Moderate Downgraded: imprecision |
Pain | Pain: not reported | 0 studies | No studies |
Root resorption | Root resorption: not reported | 0 studies | No studies |
Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to next/working arch wire | MD 0.40 [-0.11, 0.91] | 1 study · 86 participants | Ungraded |
Time to alignment 16 weeks | MD 0.5 [0.21, 0.79] 0.5 [0.21, 0.79] months | 1 study · 32 participants | Low Downgraded: risk of bias, imprecision |
Root resorption (reduction in root length) 16 weeks | MD -0.05 [-0.14, 0.04] -0.05 [-0.14, 0.04] mm (root length reduction) | 2 studies · 52 participants | Very low Downgraded: risk of bias, imprecision, inconsistency |
Alignment rate 4 to 16 weeks | MD -0.28 [-0.62, 0.06] -0.28 [-0.62, 0.06] mm/4 weeks | 5 studies · 183 participants | Low Downgraded: risk of bias, imprecision |
Pain day 1 7 days | MD 6.96 [1.82, 12.10] 6.96 [1.82, 12.10] mm (VAS) | 3 studies · 94 participants | Moderate Downgraded: imprecision |
NiTi arch wire of one cross-sectional size vs NiTi arch wire of a different cross-sectional size
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | Root resorption: not reported | 0 studies | No studies |
Pain 7 days | Different sizes of NiTi wires (Alhaija 2021; Erdinc 2004); not pooled due to clinical heterogeneity; little or no difference at day 1. Erdinc 0.014 vs 0.016 inch higher pain at day 4 MD 5.00 (0.19 to 9.81) and day 6 MD… | 2 studies · 149 participants | Low Downgraded: risk of bias, imprecision |
Time to next/working arch wire | No studies reported time to next/working arch wire | 0 studies | No studies |
Time to alignment | Time to alignment: not reported | 0 studies | No studies |
Alignment rate | Alignment rate: not reported | 0 studies | No studies |
Coated superelastic NiTi wire (BioCosmetic, Titanol, TP Aesthetic or Tooth Tone) vs A different coated superelastic NiTi wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate 8 weeks | Four-arm study of different coated superelastic NiTi wires (Ulhaq 2017); reduction in LII over 8 weeks; no difference between the four groups (ANOVA P=0.627) | 1 study | Ungraded |
Superelastic NiTi arch wire vs Titanium-niobium-tantalum-zirconium (TiNbTaZr) arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate 8 to 12 weeks | Superelastic NiTi (Sentalloy) vs TiNbTaZr (Gummetal) (Nordstrom 2018); LII change over 8 to 12 weeks; no clear difference (ANOVA P=0.6938) | 1 study · 28 participants | Ungraded |
Multistrand stainless steel wire vs Wires of other materials (conventional stainless steel, superelastic NiTi, thermoelastic NiTi)
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate 6 weeks to 6 months | Multistrand StSt versus other materials (conventional StSt, superelastic NiTi, thermoelastic NiTi); alignment rate not pooled due to clinical heterogeneity (Cobb 1998; Evans 1998; Quintao 2005; West 1995); results… | 4 studies · 281 participants | Very low Downgraded: risk of bias, imprecision |
Time to alignment | Time to alignment: not reported | 0 studies | No studies |
Root resorption | Root resorption: not reported | 0 studies | No studies |
Superelastic NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | Root resorption: not measured | 0 studies | No studies |
Time to alignment | Time to alignment: not measured | 0 studies | No studies |
Pain day 1 14 to 15 days | MD 2.68 [-1.38, 6.75] 2.68 [-1.38, 6.75] mm (VAS) | 2 studies · 127 participants | Moderate Downgraded: imprecision |
Alignment rate between first molars 8 weeks | MD 7.5 [-11.27, 26.27] 7.5 [-11.27, 26.27] mm/8 weeks (faster) | 1 study · 48 participants | Low Downgraded: imprecision |
Thermoelastic (active martensitic/heat-activated) NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | Root resorption: not measured | 0 studies | No studies |
Time to alignment | Time to alignment: not measured | 0 studies | No studies |
Pain | Pain: not measured | 0 studies | No studies |
Alignment rate between first molars 8 weeks | MD -8.78 [-27.79, 10.23] -8.78 [-27.79, 10.23] mm/8 weeks | 1 study · 42 participants | Low Downgraded: imprecision |
Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to alignment 16 weeks | MD 0.30 [-1.14, 1.74] 0.30 [-1.14, 1.74] weeks | 1 study · 49 participants | Low Downgraded: imprecision |
Alignment rate between canines about 5 weeks | MD 0.28 [-0.33, 0.89] 0.28 [-0.33, 0.89] mm | 1 study · 40 participants | Very low Downgraded: risk of bias, imprecision |
Pain day 1 7 days | MD -1.1 [-15.1, 12.9] -1.1 [-15.1, 12.9] mm (VAS) | 1 study · 79 participants | Very low Downgraded: risk of bias, imprecision |
Root resorption | Root resorption: not measured | 0 studies | No studies |
Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to alignment 16 weeks | MD -0.20 [-1.64, 1.24] -0.20 [-1.64, 1.24] weeks | 1 study · 49 participants | Low Downgraded: imprecision |
Pain | Pain: not measured | 0 studies | No studies |
Root resorption | Root resorption: not measured | 0 studies | No studies |
Alignment rate ratio (hazard ratio) 6 months | HR 1.3 [0.68, 2.50] | 1 study · 60 participants | Low Downgraded: imprecision |
Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate between canines 12 weeks | MD -5.07 [-5.99, -4.16] -5.07 [-5.99, -4.16] mm/12 weeks (single-strand slower) | 1 study · 24 participants | Moderate Downgraded: imprecision |
Root resorption | Root resorption: not measured | 0 studies | No studies |
Pain | Pain: not measured | 0 studies | No studies |
Time to alignment | Time to alignment: not measured | 0 studies | No studies |
Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | Root resorption: not measured | 0 studies | No studies |
Pain day 1 7 days | MD 7.0 [-12.56, 26.56] 7.0 [-12.56, 26.56] mm (VAS; superelastic higher) | 1 study · 30 participants | Low Downgraded: imprecision |
Time to alignment 16 weeks | MD 0.5 [-0.78, 1.78] 0.5 [-0.78, 1.78] weeks (superelastic longer) | 1 study · 50 participants | Low Downgraded: imprecision |
Alignment rate between first molars 8 weeks | MD 16.28 [-4.05, 36.61] 16.28 [-4.05, 36.61] mm/8 weeks (superelastic faster) | 1 study · 46 participants | Low Downgraded: imprecision |
Superelastic NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Tooth movement (alignment rate) 6 weeks to 6 months | Multistrand StSt vs NiTi (Cobb 1998; Jones 1992; West 1995); meta-analysis not possible; effect not estimated; trials reported different outcomes at different times with substantial clinical heterogeneity | 3 studies · 174 participants | Low Downgraded: risk of bias, inconsistency |
Pain intensity (VAS) day 1 | Multistrand StSt vs superelastic NiTi (Jones 1992); pain VAS day 1 or day 7; meta-analysis not possible; effect not estimated | 1 study · 42 participants | Very low Downgraded: risk of bias, imprecision |
Root resorption | Root resorption: not reported by any included study | 0 studies | No studies |
Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | Root resorption: not reported by any included study | 0 studies | No studies |
Pain intensity (VAS) day 1 7 days | Conventional NiTi vs superelastic NiTi (Fernandes 1998); pain VAS day 1; meta-analysis not possible (single study); effect not estimated | 1 study · 79 participants | Very low Downgraded: risk of bias, imprecision |
Tooth movement (alignment rate) 35 days | Conventional NiTi vs superelastic NiTi (O'Brien 1990); tooth movement over 35 days; meta-analysis not possible (single study); effect not estimated | 1 study · 40 participants | Very low Downgraded: risk of bias, imprecision |
Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate ratio (single-strand superelastic NiTi versus copper NiTi) 6 months | Conventional/copper NiTi comparison (Pandis 2009), grouped in this version under single-strand superelastic NiTi versus copper NiTi; alignment rate ratio not estimable in SoF | 1 study · 60 participants | Very low Downgraded: risk of bias, imprecision |
Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment (mm per 12 weeks) 12 weeks | Single-strand superelastic NiTi vs coaxial superelastic NiTi (Sebastian 2012); alignment mm per 12 weeks; not estimable; coaxial superelastic NiTi induced greater tooth movement | 1 study · 24 participants | Very low Downgraded: risk of bias, imprecision |
Root resorption | Root resorption: not reported by any included study | 0 studies | No studies |
Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Pain intensity (VAS) day 1 and day 7 (superelastic versus thermoelastic NiTi) 7 days | Superelastic NiTi vs thermoelastic NiTi (Cioffi 2012); pain VAS day 1 and day 7; not estimable | 1 study · 30 participants | Very low Downgraded: risk of bias, imprecision |
Superelastic NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Pain intensity (VAS) day 1 | MD 5.30 [-7.74, 18.34] 23.7 mm (0.015 inch multistrand StSt) vs 29 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) day 5 | MD 1.50 [-1.82, 4.82] 2.6 mm (0.015 inch multistrand StSt) vs 4.1 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) over 14 days | MD -0.40 [-3.36, 2.56] 6.1 mm (0.015 inch multistrand StSt) vs 5.7 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) day 2 | MD -5.40 [-19.22, 8.42] 25 mm (0.015 inch multistrand StSt) vs 19.6 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) day 7 | MD 0.70 [-0.57, 1.97] 0.5 mm (0.015 inch multistrand StSt) vs 1.2 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) day 4 | MD 2.90 [-1.05, 6.85] 11.0 mm (0.015 inch multistrand StSt) vs 5.5 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Pain intensity (VAS) day 6 | MD 1.70 [-1.26, 4.66] 1.2 mm (0.015 inch multistrand StSt) vs 2.9 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Alignment rate 6 weeks to 12 months | Cobb 1998: no statistically significant difference between three arch wires, reported as graphs only with no numerical data. West 1995: superelastic NiTi produced improved alignment in the mandibular labial segment… | 2 studies · 185 participants | Ungraded |
Pain intensity (VAS) day 3 | MD -8.00 [-18.22, 2.22] 20.6 mm (0.015 inch multistrand StSt) vs 12.6 mm (0.014 inch superelastic NiTi) | 1 study · 42 participants | Low Downgraded: risk of bias, imprecision |
Thermoelastic (active martensitic/heat-activated) NiTi arch wire vs Multistrand stainless steel arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Alignment rate 8 weeks | Evans 1998 (three-arm): no statistically significant difference between 0.0155 inch multistrand StSt vs 0.016x0.022 inch medium force active M-NiTi vs 0.016x0.022 inch graded force active M-NiTi. | 1 study · 51 participants | Ungraded |
Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Pain intensity (VAS) day 2 | MD 1.20 [-9.63, 12.03] 36 mm (0.014 inch NiTi) vs 37.2 mm (0.014 inch superelastic NiTi) | 1 study · 128 participants | Moderate Downgraded: risk of bias |
Pain intensity (VAS) day 6 | MD -0.50 [-5.39, 4.39] 8.8 mm (0.014 inch NiTi) vs 9.3 mm (0.014 inch superelastic NiTi) | 1 study · 125 participants | Moderate Downgraded: risk of bias |
Pain intensity (VAS) day 3 | MD 4.00 [-4.91, 12.91] 24.8 mm (0.014 inch NiTi) vs 28.8 mm (0.014 inch superelastic NiTi) | 1 study · 128 participants | Moderate Downgraded: risk of bias |
Pain intensity (VAS) day 7 | MD 0.40 [-3.81, 4.61] 6.7 mm (0.014 inch NiTi) vs 7.1 mm (0.014 inch superelastic NiTi) | 1 study · 124 participants | Moderate Downgraded: risk of bias |
Alignment rate (contact point movement) 35 days | MD 0.28 [-0.33, 0.89] 1.42 mm (0.016 inch NiTi) vs 1.7 mm (0.016 inch superelastic NiTi) | 1 study · 40 participants | Moderate Downgraded: imprecision |
Pain intensity (VAS) day 5 | MD 1.30 [-4.32, 6.92] 11.4 mm (0.014 inch NiTi) vs 12.7 mm (0.014 inch superelastic NiTi) | 1 study · 126 participants | Moderate Downgraded: risk of bias |
Pain intensity (VAS) day 4 | MD 1.60 [-5.68, 8.88] 16.7 mm (0.014 inch NiTi) vs 18.3 mm (0.014 inch superelastic NiTi) | 1 study · 127 participants | Moderate Downgraded: risk of bias |
Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire
Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Time to alignment (lower anterior arches) 6 months | HR 1.3 129.4 days (0.016 inch CuNiTi) vs 121.4 days (0.016 inch NiTi) | 1 study · 60 participants | Moderate Downgraded: indirectness |
Initial arch wire (a given material, cross-sectional shape or size) vs A different initial arch wire (different material, shape or size)
Population: Patients with upper and/or lower full arch fixed orthodontic appliances
| Outcome | Effect | Evidence | Status / GRADE |
|---|---|---|---|
Root resorption | no estimate extracted | 0 studies | No studies |
Time to next/working arch wire | no estimate extracted | 0 studies | No studies |
Pain intensity experienced by patients | no estimate extracted | 0 studies | No studies |
Alignment rate (speed of initial tooth alignment) | no estimate extracted | 0 studies | No studies |