Cochrane · intervention · CD007859

Initial arch wires used in orthodontic treatment with fixed appliances

Liu, C, Wei, Z, Jian, F, et al. · Cochrane Database of Systematic Reviews · 2024 · Cochrane Library

Oral HealthOrthodontics5 versionsAMSTAR 2: not assessed
Full textEvery question was extracted from the full review (methods and results), not only its Summary of Findings table.
Questions
34
current version
GRADE rated
12
No studies
16
Included studies
29
as reported
No studies 16 · 47.1%Ungraded 6 · 17.6%Very low 3 · 8.8%Low 7 · 20.6%Moderate 2 · 5.9%High 0 · 0%

Ungraded means an effect was reported without a GRADE rating; it is not a gap. No studies means the review found nothing to answer the question. The six categories are a display order, not a score.

Review question

ElementPlanned (methods)Found (results)
PopulationParticipants of any age with full-arch fixed orthodontic appliances on the upper arch, lower arch, or both. Excluded: concurrent palatal expansion or extraoral appliances, previous active orthodontic treatment, or relevant medical history.1915 participants (2581 arches) from 29 RCTs; sample sizes 14 to 200 participants; 13 studies included children/adolescents and adults, 13 only children/adolescents, 2 only adults.
InterventionInitial arch wire (one material, cross-sectional shape or size)Materials evaluated: conventional and multistrand stainless steel; conventional, single-strand superelastic, coaxial/multistrand superelastic, ion-implanted superelastic, coated superelastic, thermoelastic (with and without copper) NiTi; and TiNbTaZr; in sizes 0.012 to 0.018 inch
ComparisonInitial arch wires (first arch wire inserted into the fixed appliance at the beginning of treatment; excludes later arch wires), compared in terms of: (1) material; (2) cross-sectional shape; (3) cross-sectional sizeComparators drawn from the same set of stainless steel and NiTi wire types and sizes
OutcomesPrimary outcomes: alignment rate (tooth movement over a period of time); incidence/prevalence and amount of root resorption. Secondary outcomes: time to next/working arch wire; time to alignment; pain (intensity on VAS or categorical scale, and duration; analgesic consumption)Alignment rate (n=20); Root resorption (n=3); Time to next/working arch wire (n=2); Time to alignment (n=3); Pain intensity (n=13)
Study designsRandomised controlled trialsRandomised controlled trials (n=29)
TimingNot reported3 days to 6 months

Search date: 2022-07-04. Databases: Cochrane Oral Health's Trials Register; Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE Ovid; Embase Ovid; US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov; World Health Organization International Clinical Trials Registry Platform

Questions and results

Current version only

Superelastic NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Time to next/working arch wire
No studies reported time to next/working arch wire0 studiesNo studies
Root resorption
Root resorption: not reported0 studiesNo studies
Time to alignment
Cobb 1998 measured time to alignment but reported results only as graphs, with no numerical data1 studyUngraded
Pain day 1
7 to 14 days
MD 2.68 [-1.38, 6.75]
2.68 [-1.38, 6.75] mm (VAS; superelastic higher)
2 studies · 127 participantsLow
Downgraded: risk of bias, imprecision

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 5 questions
OutcomeEffectEvidenceStatus / GRADE
Time to alignment
Time to alignment: not reported0 studiesNo studies
Pain day 1
3 to 7 days
MD 0.29 [-0.52, 1.10]
0.29 [-0.52, 1.10] mm (VAS; superelastic higher)
2 studies · 142 participantsLow
Downgraded: risk of bias, imprecision
Time to next/working arch wire
MD 0.40 [-0.10, 0.90]1 study · 88 participantsUngraded
Root resorption
Root resorption: not reported0 studiesNo studies
Alignment rate
5 to 10 weeks
Conventional NiTi vs superelastic NiTi (O'Brien 1990; Ong 2011); not pooled due to clinical heterogeneity; little or no difference in alignment rate2 studies · 124 participantsLow
Downgraded: risk of bias, imprecision

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 5 questions
OutcomeEffectEvidenceStatus / GRADE
Pain
Pain: not reported0 studiesNo studies
Alignment rate
4 weeks
MD 0.10 [-0.95, 1.15]
0.10 [-0.95, 1.15] mm/4 weeks (CuNiTi faster)
1 study · 66 participantsVery low
Downgraded: risk of bias, imprecision
Time to next/working arch wire
MD 0.00 [-0.51, 0.51]1 study · 86 participantsUngraded
Time to alignment (alignment rate ratio)
6 months
HR 1.30 [0.68, 2.50]1 study · 60 participantsLow
Downgraded: imprecision
Root resorption
Root resorption: not reported0 studiesNo studies

Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 5 questions
OutcomeEffectEvidenceStatus / GRADE
Time to alignment
Time to alignment: not reported0 studiesNo studies
Time to next/working arch wire
No studies reported time to next/working arch wire0 studiesNo studies
Alignment rate
4 weeks
MD -2.64 [-4.61, -0.67]
-2.64 [-4.61, -0.67] mm/4 weeks
2 studies · 64 participantsModerate
Downgraded: imprecision
Pain
Pain: not reported0 studiesNo studies
Root resorption
Root resorption: not reported0 studiesNo studies

Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 5 questions
OutcomeEffectEvidenceStatus / GRADE
Time to next/working arch wire
MD 0.40 [-0.11, 0.91]1 study · 86 participantsUngraded
Time to alignment
16 weeks
MD 0.5 [0.21, 0.79]
0.5 [0.21, 0.79] months
1 study · 32 participantsLow
Downgraded: risk of bias, imprecision
Root resorption (reduction in root length)
16 weeks
MD -0.05 [-0.14, 0.04]
-0.05 [-0.14, 0.04] mm (root length reduction)
2 studies · 52 participantsVery low
Downgraded: risk of bias, imprecision, inconsistency
Alignment rate
4 to 16 weeks
MD -0.28 [-0.62, 0.06]
-0.28 [-0.62, 0.06] mm/4 weeks
5 studies · 183 participantsLow
Downgraded: risk of bias, imprecision
Pain day 1
7 days
MD 6.96 [1.82, 12.10]
6.96 [1.82, 12.10] mm (VAS)
3 studies · 94 participantsModerate
Downgraded: imprecision

NiTi arch wire of one cross-sectional size vs NiTi arch wire of a different cross-sectional size

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 5 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
Root resorption: not reported0 studiesNo studies
Pain
7 days
Different sizes of NiTi wires (Alhaija 2021; Erdinc 2004); not pooled due to clinical heterogeneity; little or no difference at day 1. Erdinc 0.014 vs 0.016 inch higher pain at day 4 MD 5.00 (0.19 to 9.81) and day 6 MD…2 studies · 149 participantsLow
Downgraded: risk of bias, imprecision
Time to next/working arch wire
No studies reported time to next/working arch wire0 studiesNo studies
Time to alignment
Time to alignment: not reported0 studiesNo studies
Alignment rate
Alignment rate: not reported0 studiesNo studies

Coated superelastic NiTi wire (BioCosmetic, Titanol, TP Aesthetic or Tooth Tone) vs A different coated superelastic NiTi wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 1 question
OutcomeEffectEvidenceStatus / GRADE
Alignment rate
8 weeks
Four-arm study of different coated superelastic NiTi wires (Ulhaq 2017); reduction in LII over 8 weeks; no difference between the four groups (ANOVA P=0.627)1 studyUngraded

Superelastic NiTi arch wire vs Titanium-niobium-tantalum-zirconium (TiNbTaZr) arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 1 question
OutcomeEffectEvidenceStatus / GRADE
Alignment rate
8 to 12 weeks
Superelastic NiTi (Sentalloy) vs TiNbTaZr (Gummetal) (Nordstrom 2018); LII change over 8 to 12 weeks; no clear difference (ANOVA P=0.6938)1 study · 28 participantsUngraded

Multistrand stainless steel wire vs Wires of other materials (conventional stainless steel, superelastic NiTi, thermoelastic NiTi)

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB5 (current) · 3 questions
OutcomeEffectEvidenceStatus / GRADE
Alignment rate
6 weeks to 6 months
Multistrand StSt versus other materials (conventional StSt, superelastic NiTi, thermoelastic NiTi); alignment rate not pooled due to clinical heterogeneity (Cobb 1998; Evans 1998; Quintao 2005; West 1995); results…4 studies · 281 participantsVery low
Downgraded: risk of bias, imprecision
Time to alignment
Time to alignment: not reported0 studiesNo studies
Root resorption
Root resorption: not reported0 studiesNo studies

Superelastic NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
Root resorption: not measured0 studiesNo studies
Time to alignment
Time to alignment: not measured0 studiesNo studies
Pain day 1
14 to 15 days
MD 2.68 [-1.38, 6.75]
2.68 [-1.38, 6.75] mm (VAS)
2 studies · 127 participantsModerate
Downgraded: imprecision
Alignment rate between first molars
8 weeks
MD 7.5 [-11.27, 26.27]
7.5 [-11.27, 26.27] mm/8 weeks (faster)
1 study · 48 participantsLow
Downgraded: imprecision

Thermoelastic (active martensitic/heat-activated) NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
Root resorption: not measured0 studiesNo studies
Time to alignment
Time to alignment: not measured0 studiesNo studies
Pain
Pain: not measured0 studiesNo studies
Alignment rate between first molars
8 weeks
MD -8.78 [-27.79, 10.23]
-8.78 [-27.79, 10.23] mm/8 weeks
1 study · 42 participantsLow
Downgraded: imprecision

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Time to alignment
16 weeks
MD 0.30 [-1.14, 1.74]
0.30 [-1.14, 1.74] weeks
1 study · 49 participantsLow
Downgraded: imprecision
Alignment rate between canines
about 5 weeks
MD 0.28 [-0.33, 0.89]
0.28 [-0.33, 0.89] mm
1 study · 40 participantsVery low
Downgraded: risk of bias, imprecision
Pain day 1
7 days
MD -1.1 [-15.1, 12.9]
-1.1 [-15.1, 12.9] mm (VAS)
1 study · 79 participantsVery low
Downgraded: risk of bias, imprecision
Root resorption
Root resorption: not measured0 studiesNo studies

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Time to alignment
16 weeks
MD -0.20 [-1.64, 1.24]
-0.20 [-1.64, 1.24] weeks
1 study · 49 participantsLow
Downgraded: imprecision
Pain
Pain: not measured0 studiesNo studies
Root resorption
Root resorption: not measured0 studiesNo studies
Alignment rate ratio (hazard ratio)
6 months
HR 1.3 [0.68, 2.50]1 study · 60 participantsLow
Downgraded: imprecision

Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Alignment rate between canines
12 weeks
MD -5.07 [-5.99, -4.16]
-5.07 [-5.99, -4.16] mm/12 weeks (single-strand slower)
1 study · 24 participantsModerate
Downgraded: imprecision
Root resorption
Root resorption: not measured0 studiesNo studies
Pain
Pain: not measured0 studiesNo studies
Time to alignment
Time to alignment: not measured0 studiesNo studies

Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB4 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
Root resorption: not measured0 studiesNo studies
Pain day 1
7 days
MD 7.0 [-12.56, 26.56]
7.0 [-12.56, 26.56] mm (VAS; superelastic higher)
1 study · 30 participantsLow
Downgraded: imprecision
Time to alignment
16 weeks
MD 0.5 [-0.78, 1.78]
0.5 [-0.78, 1.78] weeks (superelastic longer)
1 study · 50 participantsLow
Downgraded: imprecision
Alignment rate between first molars
8 weeks
MD 16.28 [-4.05, 36.61]
16.28 [-4.05, 36.61] mm/8 weeks (superelastic faster)
1 study · 46 participantsLow
Downgraded: imprecision

Superelastic NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB3 · 3 questions
OutcomeEffectEvidenceStatus / GRADE
Tooth movement (alignment rate)
6 weeks to 6 months
Multistrand StSt vs NiTi (Cobb 1998; Jones 1992; West 1995); meta-analysis not possible; effect not estimated; trials reported different outcomes at different times with substantial clinical heterogeneity3 studies · 174 participantsLow
Downgraded: risk of bias, inconsistency
Pain intensity (VAS) day 1
Multistrand StSt vs superelastic NiTi (Jones 1992); pain VAS day 1 or day 7; meta-analysis not possible; effect not estimated1 study · 42 participantsVery low
Downgraded: risk of bias, imprecision
Root resorption
Root resorption: not reported by any included study0 studiesNo studies

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB3 · 3 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
Root resorption: not reported by any included study0 studiesNo studies
Pain intensity (VAS) day 1
7 days
Conventional NiTi vs superelastic NiTi (Fernandes 1998); pain VAS day 1; meta-analysis not possible (single study); effect not estimated1 study · 79 participantsVery low
Downgraded: risk of bias, imprecision
Tooth movement (alignment rate)
35 days
Conventional NiTi vs superelastic NiTi (O'Brien 1990); tooth movement over 35 days; meta-analysis not possible (single study); effect not estimated1 study · 40 participantsVery low
Downgraded: risk of bias, imprecision

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB3 · 1 question
OutcomeEffectEvidenceStatus / GRADE
Alignment rate ratio (single-strand superelastic NiTi versus copper NiTi)
6 months
Conventional/copper NiTi comparison (Pandis 2009), grouped in this version under single-strand superelastic NiTi versus copper NiTi; alignment rate ratio not estimable in SoF1 study · 60 participantsVery low
Downgraded: risk of bias, imprecision

Single-strand superelastic NiTi arch wire vs Coaxial superelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB3 · 2 questions
OutcomeEffectEvidenceStatus / GRADE
Alignment (mm per 12 weeks)
12 weeks
Single-strand superelastic NiTi vs coaxial superelastic NiTi (Sebastian 2012); alignment mm per 12 weeks; not estimable; coaxial superelastic NiTi induced greater tooth movement1 study · 24 participantsVery low
Downgraded: risk of bias, imprecision
Root resorption
Root resorption: not reported by any included study0 studiesNo studies

Superelastic NiTi arch wire vs Thermoelastic NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB3 · 1 question
OutcomeEffectEvidenceStatus / GRADE
Pain intensity (VAS) day 1 and day 7 (superelastic versus thermoelastic NiTi)
7 days
Superelastic NiTi vs thermoelastic NiTi (Cioffi 2012); pain VAS day 1 and day 7; not estimable1 study · 30 participantsVery low
Downgraded: risk of bias, imprecision

Superelastic NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB2 · 9 questions
OutcomeEffectEvidenceStatus / GRADE
Pain intensity (VAS) day 1
MD 5.30 [-7.74, 18.34]
23.7 mm (0.015 inch multistrand StSt) vs 29 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) day 5
MD 1.50 [-1.82, 4.82]
2.6 mm (0.015 inch multistrand StSt) vs 4.1 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) over 14 days
MD -0.40 [-3.36, 2.56]
6.1 mm (0.015 inch multistrand StSt) vs 5.7 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) day 2
MD -5.40 [-19.22, 8.42]
25 mm (0.015 inch multistrand StSt) vs 19.6 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) day 7
MD 0.70 [-0.57, 1.97]
0.5 mm (0.015 inch multistrand StSt) vs 1.2 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) day 4
MD 2.90 [-1.05, 6.85]
11.0 mm (0.015 inch multistrand StSt) vs 5.5 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Pain intensity (VAS) day 6
MD 1.70 [-1.26, 4.66]
1.2 mm (0.015 inch multistrand StSt) vs 2.9 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision
Alignment rate
6 weeks to 12 months
Cobb 1998: no statistically significant difference between three arch wires, reported as graphs only with no numerical data. West 1995: superelastic NiTi produced improved alignment in the mandibular labial segment…2 studies · 185 participantsUngraded
Pain intensity (VAS) day 3
MD -8.00 [-18.22, 2.22]
20.6 mm (0.015 inch multistrand StSt) vs 12.6 mm (0.014 inch superelastic NiTi)
1 study · 42 participantsLow
Downgraded: risk of bias, imprecision

Thermoelastic (active martensitic/heat-activated) NiTi arch wire vs Multistrand stainless steel arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB2 · 1 question
OutcomeEffectEvidenceStatus / GRADE
Alignment rate
8 weeks
Evans 1998 (three-arm): no statistically significant difference between 0.0155 inch multistrand StSt vs 0.016x0.022 inch medium force active M-NiTi vs 0.016x0.022 inch graded force active M-NiTi.1 study · 51 participantsUngraded

Superelastic NiTi arch wire vs Conventional (stabilised) NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB2 · 7 questions
OutcomeEffectEvidenceStatus / GRADE
Pain intensity (VAS) day 2
MD 1.20 [-9.63, 12.03]
36 mm (0.014 inch NiTi) vs 37.2 mm (0.014 inch superelastic NiTi)
1 study · 128 participantsModerate
Downgraded: risk of bias
Pain intensity (VAS) day 6
MD -0.50 [-5.39, 4.39]
8.8 mm (0.014 inch NiTi) vs 9.3 mm (0.014 inch superelastic NiTi)
1 study · 125 participantsModerate
Downgraded: risk of bias
Pain intensity (VAS) day 3
MD 4.00 [-4.91, 12.91]
24.8 mm (0.014 inch NiTi) vs 28.8 mm (0.014 inch superelastic NiTi)
1 study · 128 participantsModerate
Downgraded: risk of bias
Pain intensity (VAS) day 7
MD 0.40 [-3.81, 4.61]
6.7 mm (0.014 inch NiTi) vs 7.1 mm (0.014 inch superelastic NiTi)
1 study · 124 participantsModerate
Downgraded: risk of bias
Alignment rate (contact point movement)
35 days
MD 0.28 [-0.33, 0.89]
1.42 mm (0.016 inch NiTi) vs 1.7 mm (0.016 inch superelastic NiTi)
1 study · 40 participantsModerate
Downgraded: imprecision
Pain intensity (VAS) day 5
MD 1.30 [-4.32, 6.92]
11.4 mm (0.014 inch NiTi) vs 12.7 mm (0.014 inch superelastic NiTi)
1 study · 126 participantsModerate
Downgraded: risk of bias
Pain intensity (VAS) day 4
MD 1.60 [-5.68, 8.88]
16.7 mm (0.014 inch NiTi) vs 18.3 mm (0.014 inch superelastic NiTi)
1 study · 127 participantsModerate
Downgraded: risk of bias

Thermoelastic copper NiTi (CuNiTi) arch wire vs Conventional NiTi arch wire

Population: People receiving orthodontic treatment with fixed appliances (upper and/or lower full arch)
CD007859.PUB2 · 1 question
OutcomeEffectEvidenceStatus / GRADE
Time to alignment (lower anterior arches)
6 months
HR 1.3
129.4 days (0.016 inch CuNiTi) vs 121.4 days (0.016 inch NiTi)
1 study · 60 participantsModerate
Downgraded: indirectness

Initial arch wire (a given material, cross-sectional shape or size) vs A different initial arch wire (different material, shape or size)

Population: Patients with upper and/or lower full arch fixed orthodontic appliances
CD007859 · 4 questions
OutcomeEffectEvidenceStatus / GRADE
Root resorption
no estimate extracted0 studiesNo studies
Time to next/working arch wire
no estimate extracted0 studiesNo studies
Pain intensity experienced by patients
no estimate extracted0 studiesNo studies
Alignment rate (speed of initial tooth alignment)
no estimate extracted0 studiesNo studies