Meconium aspiration syndrome (MAS) · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes meconium aspiration syndrome (MAS) compared with no tracheal suction (very low certainty).
1 finding from 1 review
Neonatal mortality · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes all‐cause neonatal mortality compared with no tracheal suction (very low certainty).
1 finding from 1 review
Moderate to severe hypoxic‐ischaemic encephalopathy (HIE) · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes moderate to severe hypoxic‐ischaemic encephalopathy (HIE) compared with no tracheal suction (very low certainty).
1 finding from 1 review
Hypoxic ischaemic encephalopathy · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes any hypoxic‐ischaemic encephalopathy (HIE) compared with no tracheal suction (very low certainty).
1 finding from 1 review
Need for mechanical ventilation · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes need for mechanical ventilation compared with no tracheal suction (very low certainty).
1 finding from 1 review
Pulmonary air leak · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes pulmonary air leaks (PAL) compared with no tracheal suction (very low certainty).
1 finding from 1 review
Persistent pulmonary hypertension · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes persistent pulmonary hypertension (PPHN) compared with no tracheal suction (very low certainty).
1 finding from 1 review
Culture‐positive sepsis · non‐vigorous neonates born through meconium‐stained amniotic fluid
It is very uncertain whether tracheal suction changes culture‐positive sepsis compared with no tracheal suction (very low certainty).
1 finding from 1 review
Pain (PIPP) · neonates with mechanical ventilation
Familiar odour (breast milk smell) showed no clear difference in PIPP during endotracheal suctioning Range of scale 0 to 21. Lower… compared with standard care (low certainty).
1 finding from 1 review
SaO 2 during endotracheal suctioning · neonates with mechanical ventilation
Familiar odour (breast milk smell) showed no clear difference in saO 2 during endotracheal suctioning compared with standard care (low certainty).
1 finding from 1 review
Pain (PIPP) · neonates with mechanical ventilation
White noise showed no clear difference in PIPP during endotracheal suctioning Range of scale 0 to 21 Lower… compared with standard care (low certainty).
1 finding from 1 review
Pain (PIPP) · neonates with mechanical ventilation
Facilitated tucking / four‐handed care / gentle human touch showed no clear difference in PIPP during endotracheal suctioning Range of scale 0 to 21. Lower… compared with standard care (moderate certainty).
1 finding from 1 review
SaO 2 during endotracheal suctioning · neonates with mechanical ventilation
Facilitated tucking / four‐handed care / gentle human touch showed no clear difference in saO 2 during endotracheal suctioning compared with standard care (low certainty).
1 finding from 1 review
SDB during endotracheal suctioning · neonates with mechanical ventilation
Facilitated tucking / four‐handed care / gentle human touch showed no clear difference in SDB during endotracheal suctioning compared with standard care (low certainty).
1 finding from 1 review
SRB during endotracheal suctioning · neonates with mechanical ventilation
Facilitated tucking / four‐handed care / gentle human touch may leads to higher SRB during endotracheal suctioning compared with standard care (low certainty).
1 finding from 1 review
Validated pain scales · neonates with mechanical ventilation
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Discomfort/pain · neonates with mechanical ventilation
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Physiological indicators · neonates with mechanical ventilation
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Heart rate · neonates with mechanical ventilation
Familiar odour (breast milk smell) showed no clear difference in heart rate compared with standard care (low certainty).
1 finding from 1 review
Behavioural indicators · neonates with mechanical ventilation
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found