Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
ITI SLA titanium screws showed no clear difference in marginal bone level change compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in implant failure compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Astra TiO2-blasted titanium screws showed no clear difference in marginal bone level change compared with branemark turned titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Steri-Oss acid-etched titanium screws showed no clear difference in implant failure compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark II turned titanium screws showed no clear difference in implant failure compared with ITI TPS solid titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark II turned titanium screws showed no clear difference in implant failure compared with ITI TPS hollow titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark IV TiUnite titanium screws showed no clear difference in implant failure compared with southern regular titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant/prosthesis failure and complications · Patients with resorbed maxillae (incl. atrophic sinuses) needing implants
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark turned titanium screws showed no clear difference in implant failure compared with IMZ TPS titanium cylinders; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
IMZ TPS titanium cylinders showed no clear difference in implant failure compared with ITI TPS solid titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
IMZ TPS titanium cylinders showed no clear difference in implant failure compared with ITI TPS hollow titanium screws; GRADE not reported.
1 finding from 1 review