Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

2,289 questions · 2,331 findings · 195 reviews · Pregnancy and Childbirth

No studies found 480 · 20.6%GRADE not reported 288 · 12.4%Very low 467 · 20%Low 630 · 27%Moderate 338 · 14.5%High 128 · 5.5%

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Uterine tachysystole combined with abnormal fetal heart rate · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

Discontinued intravenous (IV) oxytocin stimulation probably leads to lower uterine tachysystole combined with abnormal fetal heart rate compared with continued IV oxytocin stimulation (moderate certainty).

1 finding from 1 review

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Chorioamnionitis · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

It is very uncertain whether discontinued intravenous (IV) oxytocin stimulation changes chorioamnionitis compared with continued IV oxytocin stimulation (very low certainty).

1 finding from 1 review

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Use of analgesia and epidural during labour · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

Discontinued intravenous (IV) oxytocin stimulation may leads to higher use of analgesia and epidural during labour compared with continued IV oxytocin stimulation (low certainty).

1 finding from 1 review

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Intrapartum cardiotocography (CTG) abnormalities (suspicious/pathological CTGs) · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

Discontinued intravenous (IV) oxytocin stimulation probably leads to lower intrapartum cardiotocography (CTG) abnormalities… compared with continued IV oxytocin stimulation (moderate certainty).

1 finding from 1 review

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Apgar score less than 7 at 5 minutes · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

Discontinued intravenous (IV) oxytocin stimulation may leads to lower apgar score at five minutes below seven compared with continued IV oxytocin stimulation (low certainty).

1 finding from 1 review

Discontinued intravenous (IV) oxytocin stimulation vs continued IV oxytocin stimulation

Acidotic cord gasses (arterial umbilical pH < 7.10) · pregnant women in latent phase of labour stimulated with oxytocin for with induction of labour. No exclusion criteria were applied in…

Discontinued intravenous (IV) oxytocin stimulation may leads to higher acidotic cord gasses (arterial umbilical pH < 7.10) compared with continued IV oxytocin stimulation (low certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Rate of caesarean section · Low risk pregnant women. All of the women were in labour.

Admission cardiotocography showed no clear difference in incidence of caesarean section compared with intermittent auscultation (low‐risk women) (moderate certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Instrumental vaginal birth · Low risk pregnant women. All of the women were in labour.

Admission cardiotocography showed no clear difference in incidence of operative vaginal birth compared with intermittent auscultation (low‐risk women) (low certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Perinatal mortality rate (fetal and neonatal deaths excluding lethal congenital anomalies) · Low risk pregnant women. All of the women were in labour.

Admission cardiotocography showed no clear difference in perinatal mortality rate (fetal and neonatal deaths excluding lethal… compared with intermittent auscultation (low‐risk women) (moderate certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Incidence of continuous electronic fetal monitoring during labour · Low risk pregnant women. All of the women were in labour.

Admission cardiotocography may leads to higher incidence of continuous electronic fetal monitoring during labour compared with intermittent auscultation (low‐risk women) (low certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Incidence and severity of hypoxic ischaemic encephalopathy (incidence only reported) · Low risk pregnant women. All of the women were in labour.

It is very uncertain whether admission cardiotocography changes incidence and severity of hypoxic ischaemic encephalopathy… compared with intermittent auscultation (low‐risk women) (very low certainty).

1 finding from 1 review

Admission cardiotocography vs intermittent auscultation

Neonatal seizures · Low risk pregnant women. All of the women were in labour.

Admission cardiotocography showed no clear difference in incidence of seizures in the neonatal period compared with intermittent auscultation (low‐risk women) (low certainty).

1 finding from 1 review