Findings

What do systematic reviews say?

Refine by population, intervention, comparison or outcome
More filters
Evidence found and GRADE certainty

310 questions · 590 findings · 34 reviews · Oral Health

No studies found 12 · 2%GRADE not reported 470 · 79.7%Very low 23 · 3.9%Low 34 · 5.8%Moderate 51 · 8.6%High 0 · 0%

Electrical conductance devices (electronic caries monitor (ECM) and/or CarieScan Pro), used as an adjunct to clinical oral examination vs Reference standard: histology or enhanced visual examination (with or without radiographs)

Outcome not reported · Samples with a low (<15%) prevalence of caries into dentine (d3/D3); target condition = non-cavitated enamel caries.

The review found no eligible studies for this question.

1 finding from 1 review
  • Electrical conductance for the detection of dental caries 2021 · Cochrane All outcomes
    Up to 3 months between index test and reference standard (in vivo studies)
    No eligible studies. 'No studies reported the inclusion of a low prevalence (0% to 14%) of d3/D3 of tooth surfaces'; all included studies reported d3/D3 prevalence of 15% or above, so the planned low-prevalence…
    0 studies
    No studies found

Biodentine vs Calcium hydroxide (CH)

Overall success (composite of clinical and radiographic success) · Vital permanent teeth (mature or immature) with deep or extremely deep caries and asymptomatic pulp or reversible pulpitis, undergoing…

Biodentine and calcium hydroxide did not differ significantly in clinical and radiographic success (OR 3.14, 95% CI 0.91 to 10.86; ungraded subgroup analysis).

1 finding from 1 review

Mesoporous silica (SiO2) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Fluorine showed no significant difference in 24 h bond strength (MD 1.441, 95% CI -5.099 to 7.980; Moderate certainty).

1 finding from 1 review

Hydroxyapatite (e.g., nano-HAp) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs Calcium showed no significant difference in 24 h bond strength (MD -1.792, 95% CI -7.415 to 3.831; Low certainty).

2 findings from 1 review

Flavonoids (e.g., quercetin, proanthocyanidin) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + biological ACAD protocol network, Flavonoids vs Fluorine showed no significant difference in 24 h bond strength (MD 4.241, 95% CI -2.652 to 11.135; Moderate certainty).

2 findings from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium Phosphate showed no significant difference in 24 h bond strength (MD -0.009, 95% CI -4.076 to 4.058; Low certainty).

3 findings from 1 review

HEMA/EGDMA-based desensitizer vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HEMA vs Control showed no significant difference in 24 h bond strength (MD 1.899, 95% CI -3.210 to 7.009; Low certainty).

1 finding from 1 review

Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Calcium Phosphate vs Fluorine showed no significant difference in 24 h bond strength (MD 2.140, 95% CI -1.506 to 5.787; Moderate certainty).

2 findings from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Calcium showed no significant difference in 24 h bond strength (MD 2.654, 95% CI -3.216 to 8.524; Moderate certainty).

2 findings from 1 review

Mesoporous silica (SiO2) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Silica vs Calcium showed no significant difference in 24 h bond strength (MD 1.964, 95% CI -5.802 to 9.730; Moderate certainty).

1 finding from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Fluorine showed no significant difference in 24 h bond strength (MD 2.131, 95% CI -2.213 to 6.475; Low certainty).

3 findings from 1 review

Calcium phosphate agent (e.g., CPP-ACP, Ca/P-PILP, niobophosphate) vs Calcium-based agent

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Calcium Phosphate vs Calcium showed no significant difference in 24 h bond strength (MD 0.596, 95% CI -7.289 to 8.482; Low certainty).

2 findings from 1 review

Silver diamine fluoride (SDF) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

Only one in vitro study assessed a Self-Etch adhesive with the biological ACAD protocol; it was insufficient for network meta-analysis, so no pooled effect estimate is available (ungraded).

1 finding from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Peptide vs Control showed no significant difference in 24 h bond strength (MD 1.530, 95% CI -2.373 to 5.434; Moderate certainty).

3 findings from 1 review

Calcium-based agent vs Fluoride agent (e.g., NaF/SDF/KF/CaF2)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, Calcium vs Fluorine showed no significant difference in 24 h bond strength (MD -0.523, 95% CI -5.404 to 4.358; Low certainty).

1 finding from 1 review

Fluoride agent (e.g., NaF/SDF/KF/CaF2) vs No biomimetic remineralization (control)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + biological ACAD protocol network, Fluorine showed 4.197 MPa higher 24 h bond strength than Control (MD 4.197, 95% CI 1.080 to 7.314; Moderate certainty).

3 findings from 1 review

Self-assembling/remineralizing peptide (e.g., P11-4, PAA-PASP) vs Hydroxyapatite (e.g., nano-HAp)

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Etch-and-Rinse adhesive + chemical ACAD protocol network, Peptide vs HAp showed no significant difference in 24 h bond strength (MD -0.288, 95% CI -7.988 to 7.411; Very Low certainty).

2 findings from 1 review

Hydroxyapatite (e.g., nano-HAp) vs HEMA/EGDMA-based desensitizer

Immediate (24 h) resin-dentin bond strength (MPa) · Artificial caries-affected dentin (ACAD) in extracted permanent human teeth (in vitro)

In the Self-Etch adhesive + chemical ACAD protocol network, HAp vs HEMA showed no significant difference in 24 h bond strength (MD -4.815, 95% CI -10.709 to 1.079; Moderate certainty).

1 finding from 1 review