Biological complications · People with dental implants
Crestal incision led to lower biological complications compared with vestibular incision; GRADE not reported.
1 finding from 1 review
Biological complications: Odds Ratio (M-H, Fixed, 95% CI), Subtotals only (no pooled estimate reported); 1 study (Heydenrijk 2000); 4 crestal vs 1 vestibular had hyperplastic tissue over the healing abutment
1 study
GRADE not reported
Technique to increase peri-implant keratinised/attached mucosa vs No increase of keratinised/attached mucosa
Outcome not reported · Patients receiving dental implants
The review found no eligible studies for this question.
1 finding from 1 review
Prosthetic failure (2 years) · People with dental implants
Flapless implant placement showed no clear difference in prosthetic failure compared with conventional flap elevation; GRADE not reported.
1 finding from 1 review
RR 1.0 [0.14, 7.10]
1 study
GRADE not reported
One suturing technique/material vs A different suturing technique/material
Outcome not reported · Patients receiving dental implants
The review found no eligible studies for this question.
1 finding from 1 review
Implant failure · People with dental implants
Crestal incision showed no clear difference in implant failure compared with vestibular incision; GRADE not reported.
1 finding from 1 review
Aesthetics evaluated by the dentist (any validated aesthetic index) · Partially edentulous patients receiving posterior mandibular implants
Subepithelial connective tissue graft (palate) at implant placement led to lower aesthetics (pink aesthetic score, PES) evaluated by dentist compared with no augmentation; GRADE not reported.
1 finding from 1 review
Patient satisfaction (liked toothbrush) · Adults with dental implants and peri-implant mucositis at baseline
Sonic toothbrushing led to higher patient satisfaction (liked toothbrush) compared with manual toothbrushing; GRADE not reported.
1 finding from 1 review
Plaque · Adults with dental implants and peri-implant mucositis at baseline
Mechanical debridement plus topical minocycline showed no clear difference in plaque compared with mechanical debridement plus chlorhexidine gel; GRADE not reported.
1 finding from 1 review
Plaque · Adults with dental implants and peri-implant mucositis at baseline
Mechanical debridement with titanium curettes showed no clear difference in plaque compared with mechanical debridement with ultrasonic device; GRADE not reported.
1 finding from 1 review
Plaque · Adults with dental implants and peri-implant mucositis at baseline
Listerine mouthwash led to lower plaque compared with placebo mouthwash; GRADE not reported.
1 finding from 1 review
Marginal bleeding · Adults with dental implants and peri-implant mucositis at baseline
Listerine mouthwash led to lower marginal bleeding compared with placebo mouthwash; GRADE not reported.
1 finding from 1 review
Change in probing pocket depth (PPD) · Adults with dental implants and peri-implant mucositis at baseline
Mechanical debridement with titanium curettes showed no clear difference in change in probing pocket depth compared with mechanical debridement with ultrasonic device; GRADE not reported.
1 finding from 1 review
Ease of maintenance · Adults with dental implants and peri-implant mucositis at baseline
Sonic toothbrushing showed no clear difference in ease of maintenance compared with manual toothbrushing; GRADE not reported.
1 finding from 1 review
Change in probing pocket depth (PPD) · Adults with dental implants and peri-implant mucositis at baseline
Sonic toothbrushing showed no clear difference in change in probing pocket depth compared with manual toothbrushing; GRADE not reported.
1 finding from 1 review
Plaque · Adults with dental implants and peri-implant mucositis at baseline
Sonic toothbrushing showed no clear difference in plaque compared with manual toothbrushing; GRADE not reported.
1 finding from 1 review
Change in probing pocket depth (PPD) · Adults with dental implants and peri-implant mucositis at baseline
Mechanical debridement plus topical minocycline showed no clear difference in change in probing pocket depth compared with mechanical debridement plus chlorhexidine gel; GRADE not reported.
1 finding from 1 review
Marginal bleeding · Adults with dental implants and peri-implant mucositis at baseline
Subgingival chlorhexidine irrigation led to lower marginal bleeding compared with chlorhexidine mouthwash; GRADE not reported.
1 finding from 1 review
Plaque · Adults with dental implants and peri-implant mucositis at baseline
Subgingival chlorhexidine irrigation led to lower plaque compared with chlorhexidine mouthwash; GRADE not reported.
1 finding from 1 review
Change in probing pocket depth (>=4 mm) · Adults with dental implants and peri-implant mucositis at baseline
Triclosan dentifrice showed no clear difference in change in probing pocket depth (>=4 mm) compared with sodium fluoride dentifrice; GRADE not reported.
1 finding from 1 review
Probing pocket depth · Adults with dental implants and peri-implant mucositis at baseline
Listerine mouthwash led to higher probing pocket depth compared with placebo mouthwash; GRADE not reported.
1 finding from 1 review