Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive external connection implants showed no clear difference in marginal bone level change compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Steri-Oss acid-etched titanium screws showed no clear difference in implant failure compared with southern blasted/etched titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Southern regular implants showed no clear difference in implant failure compared with neoss turned implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive external connection implants showed no clear difference in implant failure compared with nobelActive internal connection implants; GRADE not reported.
1 finding from 1 review
Marginal bone level change · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive internal connection implants led to lower marginal bone level change compared with nobel Speedy Groovy external connection implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
NobelActive internal connection implants showed no clear difference in implant failure compared with nobelReplace implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Primary pairwise data unusable (implant numbers per surface not disclosed); one turned implant failed early. Data used only for the turned-vs-roughened secondary analysis (Wennstrom 2004)
1 study · 51 participants
GRADE not reported
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
WINSIX cylindrical implants showed no clear difference in implant failure compared with WINSIX tapered implants; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
Branemark Mark II turned titanium screws showed no clear difference in implant failure compared with ITI TPS hollow titanium screws; GRADE not reported.
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Implant failure · Adults with missing teeth who received osseointegrated root-formed oral implants, functionally loaded and followed for at least 1 year
1 finding from 1 review
Zygomatic implants with bone grafts (as a partial alternative to bone augmentation; some augmentation still required in the frontal maxilla) vs Conventional dental implants in augmented maxillae
Outcome not reported · Patients with a severely atrophic maxilla for whom some bone augmentation is still required in the frontal portion of the maxilla;…
The review found no eligible studies for this question.
1 finding from 1 review
Prosthesis failure · Patients who are having osseointegrated root-form dental implants
It is very uncertain whether immediate loading changes prosthesis failure compared with early loading (very low certainty).
1 finding from 1 review