Perinatal mortality · Pregnant women with singleton fetuses who were of 20 weeks' gestation and above.
Tape measurement showed no clear difference in perinatal mortality compared with clinical palpation (low certainty).
1 finding from 1 review
Intrauterine death · Pregnant women with singleton fetuses who were of 20 weeks' gestation and above.
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Caesarean section · Pregnant women with singleton fetuses who were of 20 weeks' gestation and above.
It is very uncertain whether tape measurement changes caesarean section compared with clinical palpation (very low certainty).
1 finding from 1 review
Neurodevelopmental outcomes · Pregnant women with singleton fetuses who were of 20 weeks' gestation and above.
The review found no eligible studies for this question.
1 finding from 1 review
no estimate extracted
Studies not reported
No studies found
Admission to neonatal nursery · Pregnant women with singleton fetuses who were of 20 weeks' gestation and above.
Tape measurement showed no clear difference in admission to neonatal nursery compared with clinical palpation (low certainty).
1 finding from 1 review
Vaginal birth · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in vaginal birth compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Caesarean section · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in caesarean delivery compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Neonatal admission to NICU · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in neonatal admission to NICU compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Need of misoprostol for cervical ripening · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score probably leads to lower need of misoprostol for cervical ripening compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Meconium staining of amniotic fluid · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in meconium staining of amniotic fluid compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Apgar score less than 7 at 5 minutes · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in apgar score at 5 minutes less than 7 compared with transvaginal ultrasound (moderate certainty).
1 finding from 1 review
Fetal heart rate abnormality in labour · women with singleton cephalic fetuses undergoing assessment for pre‐induction cervical ripening.
Bishop score showed no clear difference in fetal heart rate abnormality in labour compared with transvaginal ultrasound; GRADE not reported.
1 finding from 1 review
Economic factors · Patients undergoing orthodontic treatment requiring surgical (mini-screw implant) anchorage
The review found no eligible studies for this question.
1 finding from 1 review
Number of visits · Patients undergoing orthodontic treatment requiring surgical (mini-screw implant) anchorage
The review found no eligible studies for this question.
1 finding from 1 review
Residual overjet at the end of treatment · Patients undergoing orthodontic treatment requiring surgical (mini-screw implant) anchorage
The review found no eligible studies for this question.
1 finding from 1 review
Success of the anchorage device · Patients undergoing orthodontic treatment requiring surgical (mini-screw implant) anchorage
Dual mini-screw implant showed no clear difference in success of the anchorage device compared with single mini-screw implant; GRADE not reported.
1 finding from 1 review
Duration of space closure · Patients undergoing orthodontic treatment requiring surgical (mini-screw implant) anchorage
Dual mini-screw implant showed no clear difference in duration of space closure compared with single mini-screw implant; GRADE not reported.
1 finding from 1 review
Parasitological failure At 2 years · patients with treating urinary schistosomiasis
It is very uncertain whether praziquantel 40 mg/kg multiple doses changes parasitological failure At 2 years compared with single dose (very low certainty).
1 finding from 1 review
Mean percent egg reduction At 2 years · patients with treating urinary schistosomiasis
1 finding from 1 review
Parasitological failure At 3 years · patients with treating urinary schistosomiasis
It is very uncertain whether praziquantel 40 mg/kg multiple doses changes parasitological failure At 3 years compared with single dose (very low certainty).
1 finding from 1 review